Assessment of radiological consequences to a hypothetical accident of the 3-MW TRIGA Mark-II nuclear research reactor of Bangladesh

被引:1
|
作者
Mawla, Md Rosaidul [1 ]
Rahman, Anisur [2 ]
Mollah, Abdus Sattar [3 ]
Ryean, Radmim [4 ]
Islam, Md. Shafiqul [5 ]
机构
[1] Bangladesh Univ Profess, Dept Environm Sci, Mirpur 1216, Bangladesh
[2] Atom Energy Res Estab, Ctr Res Reactor, Savar 1349, Bangladesh
[3] Mil Inst Sci & Technol, Dept Nucl Sci & Engn, Mirpur 1216, Bangladesh
[4] Mil Inst Sci & Technol, Dept Elect Elect & Commun Engn, Mirpur 1216, Bangladesh
[5] Univ Dhaka, Dept Nucl Engn, Dhaka 1000, Bangladesh
关键词
Research reactor; Hypothetical accidents; Radionuclides; TEDE; CEDE; SOURCE-TERM; RELEASE;
D O I
10.1016/j.nucengdes.2024.113255
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The radiological consequences to a hypothetical accident are assessed for the 3-MW TRIGA Mark-II Nuclear Research Reactor of Bangladesh for both wet and dry seasons. Accident simulations are crucial for assessing the potential risks in the event of a nuclear accident. ORIGEN code was used to carry out the facility ' s radionuclide inventory. In the event of a hypothetical accident, the Total Effective Dose Equivalent (TEDE) is assessed using HotSpots. The findings indicate that for stability class A during the rainy season, the selected radionuclides arrived at a downwind distance of 0.03 km with an arrival time of less than one minute, and the highest TEDE, respiratory time-integrated air concentration, and ground deposition activity, respectively, were marked at 2.8E12 Sv, 9.4E-01 Bq-sec/m 3 , and 2.4E-05 kBq/m 2 . In the case of I-131 at 0.03 km from the source, the thyroid gland is the most sensitive human organ, followed by the lung, esophagus, thymus, surface bone, skin, and breast. The estimated Committed Effective Dose Equivalent (CEDE) from I-131 is 9.1E-11 Sv. In contrast, the adrenal was the most sensitive organ with a maximum CEDE of 1.3E-13 Sv in the case of Cs -137 at a downwind distance of 0.03 km. The highest TEDE values for the general public and the vicinity around the TRIGA Mark II reactor facility are lower than the annual dose limits.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Modeling and simulation of a TRIGA MARK-II research reactor using WIMSD-5B and CITATION codes
    Benaalilou, K.
    El Bardouni, T.
    Boulaich, Y.
    El Yaakoubi, H.
    Chham, E.
    Lahdour, M.
    APPLIED RADIATION AND ISOTOPES, 2019, 148 : 64 - 75
  • [32] CONSTITUTING THE THERMAL MODEL OF TRIGA MARK II NUCLEAR RESEARCH REACTOR COOLING SYSTEM
    Akay, Orhan Erdal
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2012, 32 (01) : 109 - 116
  • [33] Estimation of control rod worth, xenon effect on reactivity and power defect of BAEC TRIGA Mark-II research reactor
    Hassan, Md Mehedi
    Rumi, K. M. Jalal Uddin
    Khan, Md Nazrul Islam
    Goswami, Rajib
    MODERN PHYSICS LETTERS A, 2018, 33 (39)
  • [34] Radiological dose assessment for the hypothetical severe accident of the Tehran Research Reactor and corresponding emergency response
    Ahangari, Rohollah
    Noori-Kalkhoran, Omid
    Sadeghi, Nahid
    ANNALS OF NUCLEAR ENERGY, 2017, 99 : 272 - 278
  • [35] Power level control of the TRIGA Mark-II research reactor using the multifeedback layer neural network and the particle swarm optimization
    Coban, Ramazan
    ANNALS OF NUCLEAR ENERGY, 2014, 69 : 260 - 266
  • [36] Assessment of environmental radioactive surface contamination from a hypothetical nuclear research reactor accident
    Xoubi, Ned
    HELIYON, 2020, 6 (09)
  • [37] Thermal Hydraulic Analysis of 3 MW TRIGA Research Reactor of Bangladesh Considering Different Cycles of Burnup
    Altaf, M. H.
    Badrun, N. H.
    ATOM INDONESIA, 2014, 40 (03) : 107 - 112
  • [38] Experimental validation of the 3-D neutron kinetics algorithm of RAPID using the JS']JSI TRIGA Mark-II reactor
    Mascolino, Valerio
    Pungercic, Anze
    Snoj, Luka
    Haghighat, Alireza
    PROGRESS IN NUCLEAR ENERGY, 2024, 176
  • [39] Production and characterization of 111Ag radioisotope for medical use in a TRIGA Mark II nuclear research reactor
    Morselli, L.
    Donzella, A.
    Arzenton, A.
    Asti, M.
    Bortolussi, S.
    Corradetti, S.
    D'Agostino, G.
    Di Luzio, M.
    Ferrari, M.
    Gandini, A.
    Lunardon, M.
    Villa, V.
    Salvini, A.
    Zangrando, L.
    Zenoni, A.
    Andrighetto, A.
    APPLIED RADIATION AND ISOTOPES, 2023, 197
  • [40] Computational analysis of neutronic parameters for TRIGA Mark-II research reactor using evaluated nuclear data libraries ENDF/B-VII.0 and JENDL-3.3
    Altaf, M. H.
    Badrun, N. H.
    Chowdhury, M. T.
    ANNALS OF NUCLEAR ENERGY, 2015, 80 : 21 - 27