Diagnostic Accuracy of Optic Nerve Head and Macula OCT Parameters for Detecting Glaucoma in Eyes With and Without High Axial Myopia

被引:3
|
作者
Rezapour, Jasmin [1 ,2 ]
Walker, Evan [2 ]
Belghith, Akram [2 ]
Bowd, Christopher [2 ]
Fazio, Massimo A. [3 ,4 ]
Jiravarnsirikul, Anuwat [2 ,5 ]
Hyman, Leslie [6 ]
Jonas, Jost B. [7 ,8 ]
Weinreb, Robert N. [2 ]
Zangwill, Linda M. [2 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Ophthalmol, Univ Med Ctr, Mainz, Germany
[2] Univ Calif San Diego, Shiley Eye Inst, Hamilton Glaucoma Ctr, La Jolla, CA USA
[3] Univ Alabama Birmingham, Heersink Sch Med, Dept Ophthalmol & Visual Sci, Birmingham, AL USA
[4] Univ Alabama Birmingham, Sch Engn, Dept Biomed Engn, Birmingham, AL USA
[5] Mahidol Univ, Fac Med, Siriraj Hosp, Dept Ophthalmol, Bangkok, Thailand
[6] Thomas Jefferson Univ, Wills Eye Hosp, Philadelphia, PA USA
[7] Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, Mannheim, Germany
[8] Inst Mol & Clin Ophthalmol Basel, Basel, Switzerland
基金
美国国家卫生研究院;
关键词
PLEXIFORM LAYER THICKNESS; GANGLION-CELL COMPLEX; OPEN-ANGLE GLAUCOMA; COHERENCE TOMOGRAPHY; NORMATIVE DATABASE; LENGTH;
D O I
10.1016/j.ajo.2024.04.022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
<bold>Purpose: </bold>To characterize structural differences and assess the diagnostic accuracy of optic nerve head (ONH) and macula optical coherence tomography (OCT) parameters to detect glaucoma in eyes with and without high axial myopia. <bold>Design: </bold>Cross-sectional study. <bold>Methods: </bold>Three hundred sixty-eight glaucoma and 411 healthy eyes with no axial myopia, 393 glaucoma and 271 healthy eyes with mild axial myopia and 124 glaucoma and 85 healthy eyes with high axial myopia were included. Global and sectoral peripapillary retinal nerve fiber layer thickness (pRNFLT), Bruch's membrane opening minimum rim width (BMO-MRW), ganglion cell inner plexiform layer thickness (GCIPLT), and macula RNFLT (mRNFLT) were compared and the diagnostic accuracy for glaucoma detection was evaluated using the adjusted area under the receiver operating characteristic curve (AUC). <bold>Results: </bold>Diagnostic accuracy for ONH and macula parameters to detect glaucoma was generally high and differed by myopia group. For ONH parameters the diagnostic accuracy was highest for global (AUC = 0.95) and inferotemporal (AUC = 0.91) pRNFLT for high myopes and global BMO-MRW for nonmyopes (AUC = 1.0) and mild myopes (AUC = 0.97). For macula parameters, the diagnostic accuracy was higher in high myopes with 6 of the 11 GCIPLT global/sectors having adjusted AUCs > 0.90 compared to nonhigh myopes with no AUCs > 0.90. In all myopia groups, mRNFLT had lower AUCs than GCIPLT. <bold>Conclusions: </bold>The diagnostic accuracy for pRNFL and GCIPL was high for high axial myopic eyes and shows promise for glaucoma detection in high myopes. Further analysis is needed to determine whether the high diagnostic accuracy can be confirmed in other populations. Copyright (c) 2024 Elsevier Inc. All rights reserved.
引用
收藏
页码:77 / 91
页数:15
相关论文
共 50 条
  • [21] Correlations between axial length and deep optic nerve head structures in myopic eyes with and without open angle glaucoma
    Han, Jong Chul
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [22] Multi-Modal deep learning classifier for glaucoma diagnosis using wide optic nerve head cube scans in eyes with and without high myopia
    Rezapour, Jasmin
    Belghith, Akram
    Bowd, Christopher
    Christopher, Mark
    Jonas, Jost
    Weinreb, Robert N.
    Zangwill, Linda
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [23] EVALUATION OF OPTIC NERVE HEAD FOR DIAGNOSIS OF GLAUCOMA IN CADAVER EYES WITHOUT PRIOR HISTORY
    Senthilkumari, Srinivasan
    Neethu, Mohan
    Santhi, Radhakrishnan
    Krishnadas, Subbiah Ramaswami
    Muthukkaruppan, Veerappan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [24] Use of Contact Lenses to Optimize OCT Scans of the Optic Nerve in Glaucoma Suspects or Patients with Glaucoma with High Myopia
    Berkenstock, Meghan K.
    Parikh, Ruby A.
    Collins, Melissa D.
    Ricard, Denise A.
    Rozar, Sandra R.
    Castoro, Charles J.
    Scott, Adrienne W.
    OPHTHALMOLOGY GLAUCOMA, 2020, 3 (03): : 196 - 201
  • [25] The Optic Nerve Head in Primary Open-Angle Glaucoma Eyes With High Myopia: Characteristics and Association With Visual Field Defects
    Chen, Li-Wei
    Lan, Yu-Wen
    Hsieh, Jui-Wen
    JOURNAL OF GLAUCOMA, 2016, 25 (06) : E569 - E575
  • [26] Differing Optic Nerve Head Strains Comparing Low, High and Pathologic Myopia Eyes
    Hoang, Quan V.
    Chuangsuwanich, Thanadet
    Yu, Daryle Jason Go
    Tun, Tin A.
    Wong, Chee Wai
    Wang, Xiaofei
    Chin, Zhi Yun
    Devalla, Sripad Krishna
    Milea, Dan
    Aung, Tin
    Girard, Michael J. A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [27] Reproducibility of Optic Nerve Head Parameters Measured With Cirrus HD-OCT in Glaucomatous Eyes
    Chang, R. T.
    Mwanza, J. -C.
    Gendy, M. G.
    Oakley, J. D.
    Feuer, W. J.
    Budenz, D. L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [28] Repeatability of Optic Nerve Head Parameters Measured by Spectral-Domain OCT in Healthy Eyes
    Savini, Giacomo
    Carbonelli, Michele
    Parisi, Vincenzo
    Barboni, Piero
    OPHTHALMIC SURGERY LASERS & IMAGING, 2011, 42 (03) : 209 - 215
  • [29] Long Axial Length Normative Database in Optic Coherence Tomography for Glaucoma Diagnosis in Eyes with High Myopia
    Chang, Yu-fan
    Liu, Catherine Jui-Ling
    Ko, Yu-Chieh
    Hsu, Chih-Chien
    Chen, Mei-ju
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [30] OCT Optic Nerve Head Morphology in Myopia IV: Neural Canal Scleral Flange Remodeling in Highly Myopic Eyes
    Jiravarnsirikul, Anuwat
    Yang, Hongli
    Jeoung, Jin Wook
    Hong, Seung Woo
    Rezapour, Jasmin
    Gardiner, Stuart
    Fortune, Brad
    Girard, Michael J. A.
    Nicolela, Marcelo
    Zangwill, Linda M.
    Chauhan, Balwantray C.
    Burgoyne, Claude F.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 261 : 141 - 164