Behaviour of axially loaded UHPC-filled double skin steel tubular columns

被引:0
|
作者
Haidar, Ali [1 ]
Fam, Amir [2 ]
机构
[1] Queens Univ, Dept Civil Engn, Kingston, ON K7L 3N6, Canada
[2] Queens Univ, Kingston, ON K7L 3N6, Canada
关键词
Double-skin; Steel; UHPC; Concrete-filled tubes; Column; Finite element; FIBER-REINFORCED CONCRETE; FLEXURAL PERFORMANCE; TUBE; COMPRESSION; MODEL;
D O I
10.1016/j.jcsr.2024.108811
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates experimentally and numerically the axial loading behaviour of Ultra-high performance concrete (UHPC) (135 MPa)-filled double skin steel tubular columns. A total of 37 stub columns (450 mm long x 152 mm diameter) were tested, including totally filled control tubes and tubes filled with normal- and high-strength (NSC and HSC) concrete. The study examined the effects of outer tube diameter-to-thickness (D-o/t(o)) ratio and inner-to-outer tube dimeter ratio, which reflects UHPC wall thickness, on axial strength. A nonlinear finite element model using computer program LS-DYNA was also developed and verified. The study showed that the stubs with the thinnest outer tube (D-o/t(o) = 72) and largest inner void ratio (0.7) achieved equivalent strength to the NSC (41 MPa) totally filled thickest tube (D-o/t(o) = 32). Failure occurred by outwards local buckling of the outer tube and inwards buckling of the inner tube, along with UHPC diagonal shear failure. The peak load reduced nonlinearly as D-o/t(o) increased due to a transition from a class 1 to class 2 section, and the post-peak load drop increased with increasing concrete strength (f(c)(')) and (D-o/t(o)) ratio. As UHPC thickness reduced to a 50% volume reduction, axial strength reduced by 20-28%. The Canadian CSA S16:19 code provisions overestimated axial strength by 12-56%. A modification factor was developed and is recommended to be introduced in the code equation.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Numerical modeling of axially loaded circular concrete-filled double-skin steel tubular short columns incorporating a new concrete confinement model
    Ahmed, Mizan
    Ci, Junchang
    Yan, Xi-Feng
    Lin, Siqi
    Chen, Shicai
    STRUCTURES, 2021, 30 : 611 - 627
  • [42] Fire performance of stiffened concrete filled double skin steel tubular columns
    Shekastehband, B.
    Taromi, A.
    Abedi, K.
    FIRE SAFETY JOURNAL, 2017, 88 : 13 - 25
  • [43] Shape effect on structural fire behaviour of axially loaded Concrete Filled Tubular (CFT) stub columns
    Dai, X. H.
    Lam, D.
    TUBULAR STRUCTURES XIV, 2012, : 575 - 582
  • [44] ANALYTICAL BEHAVIOUR OF CONCRETE-FILLED DOUBLE SKIN STEEL TUBULAR STUB COLUMNS AFTER EXPOSURE TO FIRE
    Yu, Xin
    Tao, Zhong
    Han, Lin-Hai
    Uy, Brian
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 2268 - 2273
  • [45] Load-bearing capacity of axially loaded circular concrete-filled steel tubular columns
    Jegadesh, Sankar
    Jayalekshmi, Selvan
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2016, 169 (07) : 508 - 523
  • [46] Nonlinear analysis of axially loaded circular concrete-filled stainless steel tubular short columns
    Patel, Vipulkumar Ishvarbhai
    Liang, Qing Quan
    Hadi, Muhammad N. S.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 101 : 9 - 18
  • [47] Study on Axially Loaded Behavior of Lightweight Aggregate Concrete Filled Steel Tubular Columns After Fire
    Zhang, Maoting
    Zhou, Ming
    Zheng, Xiaoyao
    2016 INTERNATIONAL CONFERENCE ON ARCHITECTURE AND CIVIL ENGINEERING (ICACE 2016), 2016, : 397 - 402
  • [48] Behavior of Axially Loaded Stirrup Confinement Rectangular Concrete-Filled Steel Tubular Stub Columns
    Liu, Jing
    Wang, Wen-jun
    Ding, Fa-xing
    Zeng, Xin-fa
    Tan, Zhe
    Huang, Yan
    Wang, Bao-quan
    ADVANCES IN CIVIL ENGINEERING, 2019, 2019
  • [49] Fire behaviour of axially loaded high-strength concrete-filled circular high-strength steel tubular columns
    Du, Tao
    Liu, Faqi
    Yang, Hua
    Peng, Kang
    ENGINEERING STRUCTURES, 2025, 328
  • [50] Axially Loaded of Concrete-Encased Concrete Filled Steel Tubular Stub Columns after Fire
    Xiang, Kai
    Pan, Yanchong
    Zhao, Bi
    Wang, Guohui
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2017, 52 (06): : 1173 - 1181