Improvement of accumulated dose distribution in combined cervical cancer radiotherapy with deep learning-based dose prediction

被引:0
|
作者
Fu, Qi [1 ]
Chen, Xinyuan [1 ]
Liu, Yuxiang [1 ,2 ]
Zhang, Jingbo [3 ]
Xu, Yingjie [1 ]
Yang, Xi [1 ]
Huang, Manni [1 ]
Men, Kuo [1 ]
Dai, Jianrong [1 ]
机构
[1] Chinese Acad Medial Sci & Peking Union Med Coll, Canc Hosp, Natl Canc Ctr, Natl Clin Res Ctr Canc,Dept Radiat, Beijing, Peoples R China
[2] Wuhan Univ, Sch Phys & Technol, Wuhan, Peoples R China
[3] Canc & TB Hosp, Dept Radiotherapy Technol, Jiamusi, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2024年 / 14卷
基金
中国国家自然科学基金;
关键词
cervical cancer; combined radiotherapy; accumulated dose; deep learning; NTCP; DEFORMABLE IMAGE REGISTRATION; CONVOLUTIONAL NEURAL-NETWORK; RADIATION-THERAPY; EXTERNAL-BEAM; BRACHYTHERAPY; QUALITY; ORGANS; RISK; SEGMENTATION; VOLUMES;
D O I
10.3389/fonc.2024.1407016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Difficulties remain in dose optimization and evaluation of cervical cancer radiotherapy that combines external beam radiotherapy (EBRT) and brachytherapy (BT). This study estimates and improves the accumulated dose distribution of EBRT and BT with deep learning-based dose prediction. Materials and methods: A total of 30 patients treated with combined cervical cancer radiotherapy were enrolled in this study. The dose distributions of EBRT and BT plans were accumulated using commercial deformable image registration. A ResNet-101-based deep learning model was trained to predict pixel-wise dose distributions. To test the role of the predicted accumulated dose in clinic, each EBRT plan was designed using conventional method and then redesigned referencing the predicted accumulated dose distribution. Bladder and rectum dosimetric parameters and normal tissue complication probability (NTCP) values were calculated and compared between the conventional and redesigned accumulated doses. Results: The redesigned accumulated doses showed a decrease in mean values of V-50, V-60, and D-2cc for the bladder (-3.02%, -1.71%, and -1.19 Gy, respectively) and rectum (-4.82%, -1.97%, and -4.13 Gy, respectively). The mean NTCP values for the bladder and rectum were also decreased by 0.02 parts per thousand and 0.98%, respectively. All values had statistically significant differences (p < 0.01), except for the bladder D-2cc (p = 0.112). Conclusion: This study realized accumulated dose prediction for combined cervical cancer radiotherapy without knowing the BT dose. The predicted dose served as a reference for EBRT treatment planning, leading to a superior accumulated dose distribution and lower NTCP values.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] DeepDoseNet: A Deep Learning-Based Approach for 3D Dose Prediction
    Soomro, M. H.
    Alves, V. Leandro
    Nourzadeh, H.
    Siebers, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [32] Online dose adaptation based on accumulated dose with zero PTV margin in rectal cancer radiotherapy
    Schroder, Lukas
    Wiersema, Lisa
    Betgen, Anja
    Marijnen, Corrie
    van der Heide, Uulke
    Sonke, Jan-Jakob
    van der Bijl, Erik
    Janssen, Tomas
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4268 - S4270
  • [33] Radiotherapy Dose Distribution Prediction Based On Patient Anatomy and Dose Volume Constraints
    Ma, J.
    Nguyen, D.
    Jia, X.
    Lu, W.
    Zhou, L.
    Jiang, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E344 - E344
  • [34] Deep learning-based Cervical Cancer Classification
    Khoulqi, Ichrak
    Idrissi, Najlae
    2022 INTERNATIONAL CONFERENCE ON TECHNOLOGY INNOVATIONS FOR HEALTHCARE, ICTIH, 2022, : 30 - 33
  • [35] Dose prediction for cervical cancer in radiotherapy based on the beam channel generative adversarial network
    Xie, Hui
    Tan, Tao
    Zhang, Hua
    Li, Qing
    HELIYON, 2024, 10 (18)
  • [36] Deep Learning-based Low Dose CT Imaging
    Wang, Tonghe
    Lei, Yang
    Dong, Xue
    Tian, Zhen
    Tang, Xiangyang
    Liu, Yingzi
    Jiang, Xiaojun
    Curran, Walter J.
    Liu, Tian
    Shu, Hui-Kuo
    Yang, Xiaofeng
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [37] Deep Learning-Based 3D Dose Prediction with DVH and Contours as Inputs
    Ma, J.
    Nguyen, D.
    Jia, X.
    Lu, W.
    Zhou, L.
    Jiang, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E356 - E356
  • [38] Dose warping uncertainties for the accumulated rectal wall dose in cervical cancer brachytherapy
    van Heerden, Laura E.
    van Wieringen, Niek
    Koedooder, Kees
    Rasch, Coen R. N.
    Pieters, Bradley R.
    Bel, Arjan
    BRACHYTHERAPY, 2018, 17 (02) : 449 - 455
  • [39] A Deep Learning-Based Framework for Dose Prediction of Pancreatic Stereotactic Body Radiation Therapy
    Momin, S.
    Lei, Y.
    Wang, T.
    Zhang, J.
    Roper, J.
    Bradley, J.
    Liu, T.
    Patel, P.
    Yang, X.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [40] A Feasibility Study for Deep Learning-Based Efficient Monte Carlo Dose Calculation Method in Radiotherapy
    Lu, X.
    Li, Y.
    Mengke, Q.
    Zhou, L.
    Song, T.
    MEDICAL PHYSICS, 2021, 48 (06)