Rapid pulmonary 129Xe ventilation MRI of discharged COVID-19 patients with zigzag sampling

被引:6
|
作者
Fang, Yuan [1 ,2 ]
Li, Haidong [2 ,3 ]
Shen, Luyang [2 ]
Zhang, Ming [2 ,3 ]
Luo, Ming [2 ]
Li, Hongchuang [2 ,3 ]
Rao, Qiuchen [2 ]
Chen, Qi [2 ,3 ]
Li, Yecheng [2 ,3 ]
Li, Zimeng [1 ,2 ]
Zhao, Xiuchao [2 ,3 ]
Shi, Lei [2 ,3 ]
Zhou, Qian [2 ]
Han, Yeqing [2 ,3 ]
Guo, Fumin [2 ]
Zhou, Xin [2 ,3 ,4 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Phys, Wuhan, Peoples R China
[2] Huazhong Univ Sci & Technol, Chinese Acad Sci, Innovat Acad Precis Measurement Sci & Technol, Wuhan Inst Phys & Math,Key Lab Magnet Resonance Bi, Wuhan 430071, Peoples R China
[3] Univ Chinese Acad Sci, Beijing, Peoples R China
[4] Hainan Univ, Sch Biomed Engn, Hainan, Peoples R China
基金
中国国家自然科学基金;
关键词
hyperpolarized Xe-129; lung; ventilation MRI; zigzag sampling; HYPERPOLARIZED XE-129; HEALTHY-VOLUNTEERS; HE-3; TOLERABILITY; ACQUISITION; DISEASE; ASTHMA; SAFETY; EPI;
D O I
10.1002/mrm.30120
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To demonstrate the feasibility of zigzag sampling for 3D rapid hyperpolarized Xe-129 ventilation MRI in human. Methods Zigzag sampling in one direction was combined with gradient-recalled echo sequence (GRE-zigzag-Y) to acquire hyperpolarized Xe-129 ventilation images. Image quality was compared with a balanced SSFP (bSSFP) sequence with the same spatial resolution for 12 healthy volunteers (HVs). For another 8 HVs and 9 discharged coronavirus disease 2019 subjects, isotropic resolution Xe-129 ventilation images were acquired using zigzag sampling in two directions through GRE-zigzag-YZ. Xe-129 ventilation defect percent (VDP) was quantified for GRE-zigzag-YZ and bSSFP acquisitions. Relationships and agreement between these VDP measurements were evaluated using Pearson correlation coefficient (r) and Bland-Altman analysis. Results For 12 HVs, GRE-zigzag-Y and bSSFP required 2.2 s and 10.5 s, respectively, to acquire Xe-129 images with a spatial resolution of 3.96 x 3.96 x 10.5 mm(3). Structural similarity index, mean absolute error, and Dice similarity coefficient between the two sets of images and ventilated lung regions were 0.85 +/- 0.03, 0.0015 +/- 0.0001, and 0.91 +/- 0.02, respectively. For another 8 HVs and 9 coronavirus disease 2019 subjects, Xe-129 images with a nominal spatial resolution of 2.5 x 2.5 x 2.5 mm(3) were acquired within 5.5 s per subject using GRE-zigzag-YZ. VDP provided by GRE-zigzag-YZ was strongly correlated (R-2 = 0.93, p < 0.0001) with that generated by bSSFP with minimal biases (bias = -0.005%, 95% limit-of-agreement = [-0.414%, 0.424%]). Conclusion Zigzag sampling combined with GRE sequence provides a way for rapid Xe-129 ventilation imaging.
引用
收藏
页码:956 / 966
页数:11
相关论文
共 50 条
  • [31] Fast dynamic ventilation MRI of hyperpolarized 129Xe using spiral imaging
    Doganay, Ozkan
    Matin, Tahreema N.
    Mcintyre, Anthony
    Burns, Brian
    Schulte, Rolf F.
    Gleeson, Fergus V.
    Bulte, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2597 - 2606
  • [32] Comparing Quantitative 129xe Ventilation Analysis Pipelines Between Mri Centers
    He, M.
    Zha, W.
    Fain, S. B.
    Driehuys, B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [33] Hyperpolarized 129Xe Pulmonary MRI and Asymptomatic Atrial Septal Defect
    Matheson, Alexander M.
    Cunningham, Robin S. P.
    Bier, Elianna
    Lu, Junlan
    Dreihuys, Bastiaan
    Pickering, J. Geoffrey
    Diamantouros, Pantelis
    Islam, Ali
    Nicholson, J. Michael
    Parraga, Grace
    Blissett, Sarah
    CHEST, 2022, 161 (04) : E199 - E202
  • [34] Abnormal 129Xe Ventilation MRI and Inhaled Corticosteroid Deposition in Severe Asthma
    Thakar, A.
    Sadafi, H.
    Serajeddini, H.
    Venegas, C.
    Kjarsgaard, M.
    Konyer, N. B.
    Lavon, B.
    Dolovich, M. B.
    Nair, P.
    Svenningsen, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [35] 129Xe lung ventilation imaging in patients with long COVID without prior respiratory disease
    Saunders, Laura
    Collier, Guilhem
    Smith, Laurie
    Marshall, Helen
    Biancardi, Alberto
    Swift, Andy
    Jakymelen, Demi
    Strickland, Scarlett
    Gustafsson, Lotta
    Munro, Ryan
    Stewart, Neil
    Norquay, Graham
    Capener, David
    Group, Explain Study
    Horsley, Alex
    Thompson, A. A. Roger
    Wild, Jim
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [36] Post-acute COVID-19 Imaging Abnormalities on Hyperpolarized 129Xe MRI Persist Over 6 Months
    Niedbalski, P. J.
    Frizzell, B.
    Pelland, D.
    Monge, C.
    Castro, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [37] Hyperpolarized 129Xe MRI Identifies Ventilation Responders to Glycopyrrolate/Formoterol Fumarate in Chronic Obstructive Pulmonary Disease
    Coleman, E. M.
    Mummy, D.
    Wang, Z.
    Bier, E.
    Womack, S.
    Korzekwinski, J.
    Mammarappallil, J.
    Driehuys, B.
    Huang, Y. T.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [38] Hyperpolarized 129xe Mri Is Sensitive To Impaired Ventilation In Pediatric Cystic Fibrosis Patients With Normal Spirometry
    Walkup, L. L.
    Thomen, R.
    Akinyi, T.
    Ruppert, K.
    Cleveland, Z. I.
    Clancy, J. P.
    Woods, J. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [39] Hyperpolarized 129Xe MRI Is Sensitive to Variations in Gas Exchange Impairment in Patients with Long Haul COVID-19 and Normal Cardiac Structure and Function
    Mummy, D.
    Bier, E.
    Lu, J.
    Leewiwatwong, S.
    Bechtel, A.
    Dummer, I.
    Kabir, S.
    Korzekwinski, J.
    Williford, K.
    Martindale, S.
    Giovacchini, C. X.
    Shaz, D.
    Mammarappallil, J.
    Alenezi, F.
    Kim, R.
    Driehuys, B.
    Que, L. G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [40] Step on the 129Xe Gas: The MRI Race to Uncover Drivers of Post-COVID-19 Symptoms
    Parraga, Grace
    Matheson, Alexander M.
    RADIOLOGY, 2022, 305 (03) : 718 - 720