Optimization of column-in-column system based on non-conventional TMD concept

被引:0
|
作者
Fang, Xiaojun [1 ,2 ]
Hao, Hong [1 ,3 ]
Bi, Kaiming [4 ]
Song, Jian [1 ,2 ]
Cao, Yongsheng [1 ,2 ]
Chen, Zhangyan [1 ,2 ]
机构
[1] Guangzhou Univ, Earthquake Engn Res & Test Ctr, Guangdong Prov Key Lab Earthquake Engn & Appl Tech, Guangzhou, Peoples R China
[2] Guangzhou Univ, Sch Civil Engn, Guangzhou 510006, Guangdong Provi, Peoples R China
[3] Curtin Univ, Ctr Infrastruct Monitoring & Protect, Sch Civil & Mech Engn, Kent St, Perth 6102, Australia
[4] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Non-conventional TMD; Optimal control; Vibration mitigation; CIC system; 2DOF3S model; Frequency and seismic responses; TUNED-MASS DAMPERS; VIBRATION CONTROL; SEISMIC RESPONSES; DYNAMIC CHARACTERISTICS; OPTIMUM PARAMETERS; DESIGN; EXCITATION; IDENTIFICATION; OSCILLATIONS; REDUCTION;
D O I
10.1016/j.ijmecsci.2024.109497
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Previous studies showed that the non-conventional tuned mass damper (TMD) with large mass ratio outperforms the traditional one in respect to the structural vibration control efficiency and robustness. The authors recently proposed a novel control system based on the non-conventional TMD concept, namely the column-in-column (CIC) system, which was composed of a primary column, a secondary column and a series of interconnected springs/dashpots. In this novel system, the secondary column connected to the primary one with springs/dashpots could act as a large TMD to attenuate adverse vibration of the primary structure, and its control effectiveness was preliminarily verified through numerical investigations. However, the control robustness was found not sufficient based on the existing optimal formulae in the literature for CIC optimization. This paper presents a new design method for optimizing the CIC system for better harnessing its control effectiveness and robustness in reducing structural response. The CIC system consists of two columns with distributed mass and uniform flexural rigidity, connected by springs along the column height. The effective modal mass and modal stiffness of a specific vibration mode of the system can be straightforwardly calculated by using the EulerBernoulli beam theory. Considering the fundamental vibration mode of the system as the target response mode for vibration control, the multiple degree-of-freedom (DOF) CIC is simplified into a two DOF with three springs (2DOF3S) structural model, the design parameters, i.e., the optimal tuning frequency ratio and damping ratio of this system are derived to minimize the displacement response of the primary structure. To demonstrate the proposed design method, the effectiveness and robustness of the CIC system in controlling seismic induced structural vibrations are assessed in both the frequency and time domains. Results show that the derived optimum formulae are applicable for optimizing the TMD system with consideration of the distributed mass and deformation of the mass damper, i.e., a column in this study. The optimized CIC system has good control robustness even if the CIC is mistuned with its design parameters deviate from the optimal values by +/- 50 %. The conventional TMD system with lumped mass as the mass damper is a special case of the proposed CIC system. The optimized CIC system has favorable control efficiency in mitigating the seismic responses of structures with reduction ratios averagely varying within the range of 15 % similar to 55 % with a probability of 92.67 %. It is concluded that the proposed method is reliable and can be used for the optimum design and control of the CIC system.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] A NON-CONVENTIONAL BEVERAGE BASED ON TEA AND MALT
    VARADHARAJAN, TK
    NAGALAKSHMI, S
    SESHADRI, R
    JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 1985, 22 (01): : 51 - 53
  • [22] Magnetic induction based cluster optimization in non-conventional WSNs: A cross layer approach
    Tambe, Supriya
    Kumar, Vinay
    Bhusari, Rutuja
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2018, 93 : 53 - 62
  • [23] Exterior beam-column joint study with non-conventional reinforcement detailing using mechanical anchorage under reversal loading
    S RAJAGOPAL
    S PRABAVATHY
    Sadhana, 2014, 39 : 1185 - 1200
  • [24] Likely Performance of a Non-conventional Coal-based Combined System.
    Cicconardi, Salvatore P.
    Lensi, Roberto
    Spazzafumo, Giuseppe
    Termotecnica Milano, 1988, 42 (03): : 35 - 41
  • [25] A structure of the measurement system for a non-conventional energetic circuit
    Hlavna, Vladimír
    Eksploatacja i Niezawodnosc, 2009, 41 (01) : 11 - 14
  • [26] NON-CONVENTIONAL REVERSIBLE TOTAL ENERGY SYSTEM.
    Arosio, Sergio
    Alternative Energy Sources: Proceedings of the Miami International Congress on Energy and the Environment, 1979, 2 : 865 - 887
  • [27] A STRUCTURE OF THE MEASUREMENT SYSTEM FOR A NON-CONVENTIONAL ENERGETIC CIRCUIT
    Hlavna, Vladimir
    EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY, 2009, (01): : 11 - 14
  • [28] Optimization of Froth Feed Flotation in a Conventional Column for Beneficiation of Oxidized Coal
    Ling, Xiangyang
    He, Yaqun
    Wang, Jie
    INTERNATIONAL JOURNAL OF COAL PREPARATION AND UTILIZATION, 2021, 41 (02) : 81 - 97
  • [29] Differential Evolution based OPF with Conventional and Non-Conventional Cost Characteristics
    Vaisakh, K.
    Srinivas, L. R.
    2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 672 - +
  • [30] OPTIMIZATION OF AXIALLY LOADED NON-PRISMATIC COLUMN
    FU, KC
    REN, D
    COMPUTERS & STRUCTURES, 1992, 43 (01) : 159 - 162