Research on a Neutron Detector with a Boron-Lined Multilayer Converter

被引:0
|
作者
Deng, Chao [1 ]
Hu, Qin [1 ]
Li, Pengcheng [1 ]
Wang, Qibiao [1 ]
Xie, Bo [1 ]
Yang, Jianbo [1 ]
Tuo, Xianguo [1 ]
机构
[1] Sichuan Univ Sci & Engn, Sch Phys & Elect Engn, Zigong 643000, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 10期
基金
中国国家自然科学基金;
关键词
boron-lined neutron detector; BMCND; electron drift efficiency; energy deposition spectrum; neutron detection efficiency; SIMULATION; GEANT4;
D O I
10.3390/app14104269
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
3He is a splendid neutron detection material due to its high neutron reaction cross section, gaseous state, and nonelectronegative and nonpoisonous nature. With the worldwide problem of the "3He supply crisis" arising, boron-lined gaseous neutron detectors are being widely used in neutron detection to replace 3He neutron detectors. In this work, to reduce the scattering neutron background coming from the substrate of a boron-lined neutron detector in the application of neutron scattering, a new design of the boron-lined gaseous neutron detector composed of a boron-lined multichip converter and a multiwire proportional chamber was proposed. The electron drift efficiency matrix simulated by Garfield++ (Version 2023.4) and the values and positions of electron energy deposition simulated by Geant4 were obtained. The alpha, 7Li, and total charged particle energy deposition spectra were acquired via coupling calculations of the electron drift efficiency matrix and the values and positions of electron energy deposition, and the width of the slit was selected as 3 mm. The boron-lined multilayer converter neutron detector (BMCND) was tested using a 241Am-239Pu mixture alpha source, and the total count rate of alpha charged particles was measured as 599.5 s-1, which is 89% of the theoretical alpha particle emission rate of 672.9 s-1. The drift voltage experiments showed that 1200 V is enough to acquire a relatively ideal count, and a 2500 V drift voltage was confirmed, considering the higher count and instrument safety. We also performed the neutron detection experiments using a photo-neutron source, and a characteristic spectrum shape of "two stairs" was measured. When borated polyethylene was used to shield the BMCND, the detected total count decreased while keeping the characteristic spectrum shape, demonstrating that the BMCND was equipped with the ability to detect neurons, indicating that BMCNDs have the potential to be an outstanding 3He alternative neutron detector.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] BORON TRIFLUORIDE NEUTRON DETECTOR FOR LOW NEUTRON INTENSITIES
    SEGRE, E
    WIEGAND, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1947, 18 (02): : 86 - 89
  • [42] Indigenous development of gamma compensated boron lined neutron chambers
    Alex, M
    Prasad, DN
    Prasad, KR
    Kataria, SK
    Athavale, SN
    Pappachan, AL
    Subramanian, C
    Grover, AK
    Suri, AK
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2003, 62 (11): : 1057 - 1062
  • [43] Boron-rich semiconducting boron carbide neutron detector
    Harken, Andrew D.
    Day, Ellen E.
    Robertson, Brian W.
    Adenwalla, Shireen
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2005, 44 (1 A): : 444 - 445
  • [44] Boron-rich semiconducting boron carbide neutron detector
    Harken, AD
    Day, EE
    Robertson, BW
    Adenwalla, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (1A): : 444 - 445
  • [45] Design and performance of A 3He-free coincidence counter based on parallel plate boron-lined proportional technology
    Henzlova, D.
    Menlove, H. O.
    Marlow, J. B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 788 : 188 - 193
  • [46] BORON-CONTAINING LIQUID NEUTRON DETECTOR
    KITAEV, VY
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (04): : 1011 - &
  • [47] A TERPHENYL-BORON LIQUID NEUTRON DETECTOR
    CAMPBELL, WH
    HOPKINS, JI
    PHYSICAL REVIEW, 1953, 91 (01): : 224 - 224
  • [48] A Micro Pixel Chamber Based Neutron Imaging Detector with Boron Converter for Energy-Resolved Neutron Imaging at J-PARC
    Parker, Joseph D.
    Harada, Masahide
    Hayashida, Hirotoshi
    Hiroi, Kosuke
    Kai, Tetsuya
    Matsumoto, Yoshihiro
    Oikawa, Kenichi
    Segawa, Mariko
    Shinohara, Takenao
    Su, Yuhua
    Takada, Atsushi
    Taniguchi, Tomoyuki
    Tanimori, Toru
    Kiyanagi, Yoshiaki
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [49] A position-sensitive wire-strip thermal- and cold-neutron detector with a boron converter
    Litvin V.S.
    Potashev S.I.
    Razin V.I.
    Sadykov R.A.
    Bulletin of the Russian Academy of Sciences: Physics, 2011, 75 (02) : 229 - 231
  • [50] Experimental research on a boron-coated multi-wire proportional chamber neutron detector
    Ying Zhang
    Yan-Feng Wang
    Xiao-Hu Wang
    Xiao-qing Tu
    Jian-Rong Zhou
    Bo Yang
    Zhi-Jia Sun
    Ping Cao
    Qi An
    Jian Gong
    The European Physical Journal Plus, 132