Research on a Neutron Detector with a Boron-Lined Multilayer Converter

被引:0
|
作者
Deng, Chao [1 ]
Hu, Qin [1 ]
Li, Pengcheng [1 ]
Wang, Qibiao [1 ]
Xie, Bo [1 ]
Yang, Jianbo [1 ]
Tuo, Xianguo [1 ]
机构
[1] Sichuan Univ Sci & Engn, Sch Phys & Elect Engn, Zigong 643000, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 10期
基金
中国国家自然科学基金;
关键词
boron-lined neutron detector; BMCND; electron drift efficiency; energy deposition spectrum; neutron detection efficiency; SIMULATION; GEANT4;
D O I
10.3390/app14104269
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
3He is a splendid neutron detection material due to its high neutron reaction cross section, gaseous state, and nonelectronegative and nonpoisonous nature. With the worldwide problem of the "3He supply crisis" arising, boron-lined gaseous neutron detectors are being widely used in neutron detection to replace 3He neutron detectors. In this work, to reduce the scattering neutron background coming from the substrate of a boron-lined neutron detector in the application of neutron scattering, a new design of the boron-lined gaseous neutron detector composed of a boron-lined multichip converter and a multiwire proportional chamber was proposed. The electron drift efficiency matrix simulated by Garfield++ (Version 2023.4) and the values and positions of electron energy deposition simulated by Geant4 were obtained. The alpha, 7Li, and total charged particle energy deposition spectra were acquired via coupling calculations of the electron drift efficiency matrix and the values and positions of electron energy deposition, and the width of the slit was selected as 3 mm. The boron-lined multilayer converter neutron detector (BMCND) was tested using a 241Am-239Pu mixture alpha source, and the total count rate of alpha charged particles was measured as 599.5 s-1, which is 89% of the theoretical alpha particle emission rate of 672.9 s-1. The drift voltage experiments showed that 1200 V is enough to acquire a relatively ideal count, and a 2500 V drift voltage was confirmed, considering the higher count and instrument safety. We also performed the neutron detection experiments using a photo-neutron source, and a characteristic spectrum shape of "two stairs" was measured. When borated polyethylene was used to shield the BMCND, the detected total count decreased while keeping the characteristic spectrum shape, demonstrating that the BMCND was equipped with the ability to detect neurons, indicating that BMCNDs have the potential to be an outstanding 3He alternative neutron detector.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Research on angle sensitivity of the boron-lined multilayer converter neutron detector
    Deng, Chao
    Liu, Fule
    Wang, Qibiao
    Tuo, Xianguo
    Peng, Shuming
    Wu, Yang
    Yang, Hongchao
    Dai, Heng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (06)
  • [2] Research on a Neutron Detector With a Boron-Lined Honeycomb Neutron Converter
    Fang, Zhujun
    Yang, Yigang
    Li, Yulan
    Zhang, Zhi
    Wang, Xuewu
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (04) : 1048 - 1055
  • [3] Neutron imaging and spatial resolution evaluation of the boron-lined honeycomb neutron converter based detector
    Fang, Zhujun
    Yang, Yigang
    Li, Yulan
    Zhang, Zhi
    Wang, Xuewu
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [4] Experimental validation and testing of a NaI boron-lined neutron detector
    Metwally, Walid A.
    Emam, Amira G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2018, 422 : 7 - 11
  • [5] The Research on the Effect of Boron Layer Roughness for the Detection Efficiency of Boron-lined Gaseous Neutron Detector
    Fang, Zhujun
    Yang, Yigang
    Li, Yulan
    Wang, Xuewu
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [6] The Research of High Detection Efficiency Boron Lined Detector with a Honeycomb Neutron Converter
    Fang, Zhujun
    Yang, Yigang
    Li, Yulan
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [7] Study of uniform drift electric field used for boron-lined honeycomb neutron detector
    Fang, Zhujun
    Yang, Yigang
    Li, Yulan
    Zhang, Zhi
    Wang, Xuewu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954 (954):
  • [8] Study of Boron-Lined Straw-Tube Detector Array for Neutron Scattering Measurement
    Chen, Cai
    Yang, Yigang
    Zhu, Shounuo
    Huang, Weiqi
    Gong, Hui
    Wang, Xuewu
    Li, Yuanjing
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 176 - 179
  • [9] Boron-lined proportional counters with improved neutron sensitivity
    Dighe, PM
    Prasad, DN
    Prasad, KR
    Kataria, SK
    Athavale, SN
    Pappachan, AL
    Grover, AK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 496 (01): : 154 - 161
  • [10] Design and response function of fast neutron detector using boron-lined ionization chamber
    Zhang, Zi-Xia
    Wei, Zhi-Yong
    Fang, Mei-Hua
    Zhu, Li
    Chen, Guo-Yun
    Shi, Miao
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2014, 48 (07): : 1274 - 1280