Effect of printing layer thickness on the trueness of 3-unit interim fixed partial dentures

被引:28
|
作者
Cakmak, Gulce [1 ,4 ]
Cuellar, Alfonso Rodriguez [2 ]
Donmez, Mustafa Borga [3 ,4 ]
Abou-Ayash, Samir [5 ]
Lu, Wei-En [6 ]
Schimmel, Martin [7 ,8 ]
Yilmaz, Burak [7 ,9 ,10 ]
机构
[1] Univ Bern, Buser Fdn Scholar Implant Dent, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[2] Clin Dent Rodriguez Dent Clin, Dept Periodontol, Mexico City, DF, Mexico
[3] Istinye Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkiye
[4] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
[5] Univ Bern, Dept Reconstruct Dent & Gerodontol, Sect Digital Implant & Reconstruct Dent, Bern, Switzerland
[6] Ohio State Univ, Coll Publ Hlth, Div Biostat, Columbus, OH USA
[7] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[8] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[9] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[10] Ohio State Univ, Div Restorat & Prosthet Dent, Coll Dent, Columbus, OH USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 131卷 / 04期
关键词
MARGINAL ADAPTATION; 4-UNIT FDPS; IN-VITRO; FIT; ACCURACY; CROWNS; ZIRCONIA; COCR;
D O I
10.1016/j.prosdent.2022.04.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Three-dimensional printing has facilitated the fabrication processes in dentistry. However, knowledge on the effect of layer thickness on the trueness of 3D printed fixed partial dentures (FPDs) is lacking. Purpose. The purpose of this in vitro study was to compare the effect of printing layer thickness on the trueness of 3-unit interim FPDs fabricated by using additive manufacturing with that of those fabricated by subtractive manufacturing. Material and methods. The right first premolar and first molar teeth of a dentate mandibular model were prepared for a 3-unit restoration and then digitized by using an intraoral scanner. A 3-unit interim FPD was designed to fabricate 40 restorations by using either the additive (NextDent C&B MFH) with layer thicknesses of 20 mu m (n=10), 50 mu m (n=10), and 100 mu m (n=10) or subtractive manufacturing technique (Upcera) (milled, n=10). After fabrication, the interim FPDs were digitized by using the same intraoral scanner and were superimposed over the design data by using a 3D analysis software program. Root mean square (RMS) was used to analyze the trueness of the restorations at 4 different surfaces (external, intaglio, marginal area, and intaglio occlusal) and as a complete unit (overall). Data were analyzed with the Kruskal-Wallis and Wilcoxon tests with Bonferroni correction (a=.05). Results. The 100-mu m-layer thickness interim FPDs showed the greatest overall (P<.015), external (P<.021), and intaglio occlusal (P<.021) deviations, whereas the milled interim FPDs showed the lowest (P=.001). No significant differences were found among the test groups for marginal RMS (P >=.108). The differences between the 50-<mu>m-layer thickness and 100-mu m-layer thickness interim FPDs for the intaglio surface deviations (P=.064) and between the 20-mu m-layer thickness and 50 mu m-layer thickness interim FPDs for each surface tested were not statistically significant (P>.108). Conclusions. The printing layer thickness had a significant effect on the trueness of the additively trueness than those additively manufactured, regardless of the printing layer thickness.
引用
收藏
页码:718 / 725
页数:8
相关论文
共 50 条
  • [21] Effect of Two Methods of Reinforcement on the Fracture Strength of Interim Fixed Partial Dentures
    Fahmy, Nadia Z.
    Sharawi, Amr
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (06): : 512 - 520
  • [22] Effect of pontic height on the fracture strength of reinforced interim fixed partial dentures
    Pfeiffer, P.
    Grube, L.
    DENTAL MATERIALS, 2006, 22 (12) : 1093 - 1097
  • [23] Effect of polyester fiber reinforcement on the mechanical properties of interim fixed partial dentures
    Gopichander, N.
    Kumarai, K. V. Halini
    Vasanthakumar, M.
    SAUDI DENTAL JOURNAL, 2015, 27 (04) : 194 - 200
  • [24] Marginal fit of 3-unit implant-supported fixed partial dentures: Influence of pattern fabrication method and repeated porcelain firings
    Giti, Rashin
    Farrahi, Pardis
    PLOS ONE, 2024, 19 (04):
  • [25] Effect of support structures on the trueness and precision of 3D printing dentures: An in vitro study
    Namano, Sahaprom
    Kanazawa, Manabu
    Katheng, Awutsadaporn
    Trang, Bui Ngoc Huyen
    Hada, Tamaki
    Komagamine, Yuriko
    Iwaki, Maiko
    Minakuchi, Shunsuke
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 114 - 121
  • [26] A new method to reinforce fixed interim partial dentures.
    Arcidiacono, A
    Baldissara, P
    Scotti, R
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 947 - 947
  • [27] The effect of placement and quantity of glass fibers on the fracture resistance of interim fixed partial dentures
    Nohrström, TJ
    Vallittu, PK
    Yli-Urpo, A
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2000, 13 (01) : 72 - 78
  • [28] Fracture strength of artificially aged 3-unit adhesive fixed partial dentures made of fiber-reinforced composites and ceramics: An in vitro study
    Kolbeck, Carola
    Rosentritt, Martin
    Handel, Gerhard
    QUINTESSENCE INTERNATIONAL, 2006, 37 (09): : 731 - 735
  • [29] Fracture strength and energy-dispersive spectroscopy analysis of 3-unit fixed partial dentures fabricated from different monolithic zirconia materials
    Erdinc, Gulbahar
    Bulbul, Mehmet
    Ozcan, Mutlu
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06): : 938.e1 - 938.e7
  • [30] EVALUATION OF MULTIPLE UNIT CASTINGS FOR FIXED PARTIAL DENTURES
    BRUCE, RW
    JOURNAL OF PROSTHETIC DENTISTRY, 1964, 14 (05): : 939 - &