Effect of printing layer thickness on the trueness of 3-unit interim fixed partial dentures

被引:28
|
作者
Cakmak, Gulce [1 ,4 ]
Cuellar, Alfonso Rodriguez [2 ]
Donmez, Mustafa Borga [3 ,4 ]
Abou-Ayash, Samir [5 ]
Lu, Wei-En [6 ]
Schimmel, Martin [7 ,8 ]
Yilmaz, Burak [7 ,9 ,10 ]
机构
[1] Univ Bern, Buser Fdn Scholar Implant Dent, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[2] Clin Dent Rodriguez Dent Clin, Dept Periodontol, Mexico City, DF, Mexico
[3] Istinye Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkiye
[4] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
[5] Univ Bern, Dept Reconstruct Dent & Gerodontol, Sect Digital Implant & Reconstruct Dent, Bern, Switzerland
[6] Ohio State Univ, Coll Publ Hlth, Div Biostat, Columbus, OH USA
[7] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[8] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[9] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[10] Ohio State Univ, Div Restorat & Prosthet Dent, Coll Dent, Columbus, OH USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 131卷 / 04期
关键词
MARGINAL ADAPTATION; 4-UNIT FDPS; IN-VITRO; FIT; ACCURACY; CROWNS; ZIRCONIA; COCR;
D O I
10.1016/j.prosdent.2022.04.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Three-dimensional printing has facilitated the fabrication processes in dentistry. However, knowledge on the effect of layer thickness on the trueness of 3D printed fixed partial dentures (FPDs) is lacking. Purpose. The purpose of this in vitro study was to compare the effect of printing layer thickness on the trueness of 3-unit interim FPDs fabricated by using additive manufacturing with that of those fabricated by subtractive manufacturing. Material and methods. The right first premolar and first molar teeth of a dentate mandibular model were prepared for a 3-unit restoration and then digitized by using an intraoral scanner. A 3-unit interim FPD was designed to fabricate 40 restorations by using either the additive (NextDent C&B MFH) with layer thicknesses of 20 mu m (n=10), 50 mu m (n=10), and 100 mu m (n=10) or subtractive manufacturing technique (Upcera) (milled, n=10). After fabrication, the interim FPDs were digitized by using the same intraoral scanner and were superimposed over the design data by using a 3D analysis software program. Root mean square (RMS) was used to analyze the trueness of the restorations at 4 different surfaces (external, intaglio, marginal area, and intaglio occlusal) and as a complete unit (overall). Data were analyzed with the Kruskal-Wallis and Wilcoxon tests with Bonferroni correction (a=.05). Results. The 100-mu m-layer thickness interim FPDs showed the greatest overall (P<.015), external (P<.021), and intaglio occlusal (P<.021) deviations, whereas the milled interim FPDs showed the lowest (P=.001). No significant differences were found among the test groups for marginal RMS (P >=.108). The differences between the 50-<mu>m-layer thickness and 100-mu m-layer thickness interim FPDs for the intaglio surface deviations (P=.064) and between the 20-mu m-layer thickness and 50 mu m-layer thickness interim FPDs for each surface tested were not statistically significant (P>.108). Conclusions. The printing layer thickness had a significant effect on the trueness of the additively trueness than those additively manufactured, regardless of the printing layer thickness.
引用
收藏
页码:718 / 725
页数:8
相关论文
共 50 条
  • [1] Retrospective survival analysis of 3-unit fixed-fixed and 2-unit cantilevered fixed partial dentures
    Chai, J
    Chu, FCS
    Newsome, PRH
    Chow, TW
    JOURNAL OF ORAL REHABILITATION, 2005, 32 (10) : 759 - 765
  • [2] Fracture strength of different types of anterior 3-unit fixed partial dentures.
    Koutayas, SO
    Kheradmandan, S
    Bernhard, M
    Strub, JR
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 343 - 343
  • [3] Effect of Printing Layer Thickness on the Trueness and Margin Quality of 3D-Printed Interim Dental Crowns
    Cakmak, Guelce
    Cuellar, Alfonso Rodriguez
    Donmez, Mustafa Borga
    Schimmel, Martin
    Abou-Ayash, Samir
    Lu, Wei-En
    Yilmaz, Burak
    APPLIED SCIENCES-BASEL, 2021, 11 (19):
  • [4] Effect of Aging Procedures on Phase Transformation of Posterior 3-Unit Zirconia Frameworks Used in Fixed Partial Dentures
    Bulbul, M.
    Palta, N.
    Erdinc, G.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2025, 28 (02) : 188 - 194
  • [5] Effect of printing orientation on the fracture strength of additively manufactured 3-unit interim fixed dental prostheses after aging
    Turksayar, Almira Ada Diken
    Donmez, Mustafa Borga
    Olcay, Emin Orkun
    Demirel, Munir
    Demir, Esra
    JOURNAL OF DENTISTRY, 2022, 124
  • [6] Immediate loading of implants with 3-unit fixed partial dentures: A 12-month clinical study
    Cornelini, Roberto
    Cangini, Filippo
    Covani, Ugo
    Barone, Antonio
    Buser, Daniel
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (06) : 914 - 918
  • [7] Influence of speed sintering on the fit and fracture strength of 3-unit monolithic zirconia fixed partial dentures
    Kauling, Ana Elisa
    Gueth, Jan-Frederik
    Erdelt, Kurt
    Edelhoff, Daniel
    Keul, Christine
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (03): : 380 - 386
  • [8] Survival Rate of 3-unit Fixed Partial Dentures Replacing First Molars: A Retrospective Cohort Study
    Yoshino, Koichi
    Ito, Koji
    Kuroda, Masahiko
    Sugihara, Naoki
    BULLETIN OF TOKYO DENTAL COLLEGE, 2022, 63 (04): : 159 - 165
  • [9] Fatigue Resistance of 3-Unit CAD-CAM Ceramic Fixed Partial Dentures: An FEA Study
    Bataineh, Khaled
    Al Janaideh, Mohammad
    Abu-Naba'a, Layla A.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (09): : 806 - 814
  • [10] Effect of different sintering protocols on the fracture strength of 3-unit monolithic gradient zirconia fixed partial dentures: An in vitro study
    Attia, Mazen A.
    Radwan, Mohamed
    Blunt, Liam
    Bills, Paul
    Tawfik, Ahmed
    Arafa, Ahmed M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (06): : 908.e1 - 908.e8