CORRECTION OF INTENSITY INHOMOGENEITY IN MAGNETIC RESONANCE IMAGES USING RAMP FILTER

被引:0
|
作者
Kazantsev, I. G. [1 ]
Tankibayeva, A. K. [2 ]
Kumargazhanova, S. K. [2 ]
Azamatov, B. N. [2 ]
机构
[1] Inst Computat Math & Math Geophys, Prosp Akad Lavrentiev 6, Novosibirsk 630090, Russia
[2] D Serikbayev East Kazakhstan Tech Univ, D Serikbayevstr 19, Ust Kamenogorsk 070004, Kazakhstan
关键词
magnetic resonance imaging; intensity inhomogeneity; correction; bias field; ramp filter;
D O I
10.33048/semi.2024.21.023
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
The paper deals with the problem of correcting the intensity nonuniformity in magnetic resonance images. This problem is due to the peculiarities of the imaging equipment, may be caused by magnetic coils, and other technical reasons. In the paper, the method of removing such noise using ramp filter known also as the rho filter is considered. The numerical experiments on test images and real-world images of small animals are presented.
引用
收藏
页码:307 / 314
页数:8
相关论文
共 50 条
  • [21] Intensity non-uniformity correction of magnetic resonance images using a fuzzy segmentation algorithm
    Shen, S.
    Sandham, W. A.
    Granat, M. H.
    Sterr, A.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3035 - 3038
  • [22] Correcting surface coil intensity inhomogeneity improves quantitative analysis of cardiac magnetic resonance images
    Hsu, Li-Yueh
    Aletras, Anthony H.
    Arai, Andrew E.
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1425 - 1428
  • [23] Enhancement and Intensity Inhomogeneity Correction of Diffusion-Weighted MR Images of Neonatal and Infantile Brain Using Dynamic Stochastic Resonance
    Munendra Singh
    Shiru Sharma
    Ashish Verma
    Neeraj Sharma
    Journal of Medical and Biological Engineering, 2017, 37 : 508 - 518
  • [24] Enhancement and Intensity Inhomogeneity Correction of Diffusion-Weighted MR Images of Neonatal and Infantile Brain Using Dynamic Stochastic Resonance
    Singh, Munendra
    Sharma, Shiru
    Verma, Ashish
    Sharma, Neeraj
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2017, 37 (04) : 508 - 518
  • [25] Correction of Intensity Inhomogeneity in SAR Images via Variational Approach
    Xiao, Bin
    Peng, Yaxin
    2013 21ST INTERNATIONAL CONFERENCE ON GEOINFORMATICS (GEOINFORMATICS), 2013,
  • [26] Multi-feature intensity inhomogeneity correction in MR images
    Vovk, U
    Pernus, F
    Likar, B
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 1, PROCEEDINGS, 2004, 3216 : 283 - 290
  • [27] Field inhomogeneity correction using partial differential phases in magnetic resonance imaging
    Yang, Young-Joong
    Park, Jinho
    Yoon, Jong-Hyun
    Ahn, Chang-Beom
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10): : 4075 - 4088
  • [28] RF inhomogeneity correction algorithm in magnetic resonance imaging
    Hernández, JA
    Mora, ML
    Schiavi, E
    Toharia, P
    BIOLOGICAL AND MEDICAL DATA ANALYSIS, PROCEEDINGS, 2004, 3337 : 1 - 8
  • [29] Longitudinal Intensity Normalization of Magnetic Resonance Images using Patches
    Roy, Snehashis
    Carass, Aaron
    Prince, Jerry L.
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [30] Segmentation of ultrasound B-mode images with intensity inhomogeneity correction
    Xiao, GF
    Brady, M
    Noble, JA
    Zhang, YY
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (01) : 48 - 57