CORRECTION OF INTENSITY INHOMOGENEITY IN MAGNETIC RESONANCE IMAGES USING RAMP FILTER

被引:0
|
作者
Kazantsev, I. G. [1 ]
Tankibayeva, A. K. [2 ]
Kumargazhanova, S. K. [2 ]
Azamatov, B. N. [2 ]
机构
[1] Inst Computat Math & Math Geophys, Prosp Akad Lavrentiev 6, Novosibirsk 630090, Russia
[2] D Serikbayev East Kazakhstan Tech Univ, D Serikbayevstr 19, Ust Kamenogorsk 070004, Kazakhstan
关键词
magnetic resonance imaging; intensity inhomogeneity; correction; bias field; ramp filter;
D O I
10.33048/semi.2024.21.023
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
The paper deals with the problem of correcting the intensity nonuniformity in magnetic resonance images. This problem is due to the peculiarities of the imaging equipment, may be caused by magnetic coils, and other technical reasons. In the paper, the method of removing such noise using ramp filter known also as the rho filter is considered. The numerical experiments on test images and real-world images of small animals are presented.
引用
收藏
页码:307 / 314
页数:8
相关论文
共 50 条
  • [1] Intensity Inhomogeneity Correction of Magnetic Resonance Images using Patches
    Roy, Snehashis
    Carass, Aaron
    Bazin, Pierre-Louis
    Prince, Jerry L.
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [2] Inhomogeneity correction of magnetic resonance images by minimization of intensity overlapping
    Gispert, JD
    Reig, S
    Pascau, J
    Martínez Lázaro, R
    Vaquero, JJ
    Desco, M
    2003 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL 2, PROCEEDINGS, 2003, : 847 - 850
  • [3] Evaluating intensity standardization and inhomogeneity correction in magnetic resonance images
    Madabhushi, A
    Udupa, JK
    PROCEEDINGS OF THE IEEE 28TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2002, : 137 - 138
  • [4] Inhomogeneity Correction in Magnetic Resonance Images Using Deep Image Priors
    Han, Shuo
    Prince, Jerry L.
    Carass, Aaron
    MACHINE LEARNING IN MEDICAL IMAGING, MLMI 2020, 2020, 12436 : 404 - 413
  • [5] INTENSITY INHOMOGENEITY CORRECTION AND SEGMENTATION OF MAGNETIC RESONANCE IMAGES USING A MULTI-STAGE FUZZY CLUSTERING APPROACH
    Szilagyi, Sandor M.
    Szilagyi, Laszlo
    Iclanzan, David
    David, Laszlo
    Frigy, Attila
    Benyo, Zoltan
    NEURAL NETWORK WORLD, 2009, 19 (05) : 513 - 528
  • [6] Simultaneous Segmentation and Inhomogeneity Correction in Magnetic Resonance Images
    Li, Yue
    Hoover-Fong, Julie
    Carrino, John A.
    Mori, Susumu
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 8045 - 8048
  • [7] Intensity inhomogeneity correction of MRI images using InhomoNet
    Venkatesh, Vishal
    Sharma, Neeraj
    Singh, Munendra
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2020, 84
  • [8] Inhomogeneity correction for brain magnetic resonance images by rank leveling
    Chen, J
    Reutens, DC
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (05) : 668 - 676
  • [9] Adaptive segmentation of magnetic resonance images with intensity inhomogeneity using level set method
    Liu, Lixiong
    Zhang, Qi
    Wu, Min
    Li, Wu
    Shang, Fei
    MAGNETIC RESONANCE IMAGING, 2013, 31 (04) : 567 - 574
  • [10] Context Dependent Fuzzy Associated Statistical Model for Intensity Inhomogeneity Correction From Magnetic Resonance Images
    Subudhi, Badri Narayan
    Veerakumar, T.
    Esakkirajan, S.
    Ghosh, Ashish
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2019, 7