Numerical and experimental investigations on a single stage GM-type double inlet pulse tube refrigerator for nitrogen liquefaction

被引:0
|
作者
Panda, Debashis [1 ]
Kumar, Manoj [1 ]
Satapathy, Ashok K. [1 ]
Sarangi, Sunil K. [2 ]
Sahoo, Ranjit K. [1 ]
机构
[1] NIT Rourkela, Dept Mech Engn, Rourkela, Odisha, India
[2] IIT Bhubaneswar, Sch Mech Engn, Bhubaneswar, Odisha, India
关键词
DIPTR; Waiting time; COP; Experimental; Mesh-heat exchanger; Shell and tube heat exchanger;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, a set of non-linear partial differential equations representing the inside fluid flow, and thermal characteristics of a GM-type double inlet pulse tube refrigerator are transformed into algebraic equations by adopting "finite volume method". Those sets of equations are solved by using Gauss-Siedel iterative methods. By using the numerical model, influences of waiting time of rotary valve, orifice and bypass opening coefficients on cooling capacity, COP and mass flow ratios are studied. The mass flow rate at the pulse tube is obtained from numerical analysis, and then used to design shell-and-tube and mesh-filled hot heat exchangers. A test-rig is constructed to validate the numerical results. The performance of both the hot heat exchangers are studied experimentally. Numerical results show that the proposed numerical model is capable of producing 32.5 W of refrigeration power at 75 K. However, preliminary experimental results show a no-load temperature of 133 K.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Experimental and Numerical Characterization of an Orifice type Cryogenic Pulse Tube Refrigerator
    Antao, Dion Savio
    Farouk, Bakhtier
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 8, 2012, : 909 - 918
  • [32] Analysis of DC gas flow in GM type double inlet pulse tube refrigerators
    Zhu, Shaowei
    Nogawa, Masafumi
    Inoue, Tatsuo
    CRYOGENICS, 2009, 49 (02) : 66 - 71
  • [33] An experimental investigation of a single-stage two-pulse-tube refrigerator
    Yuan, J
    Pfotenhauer, JM
    CRYOCOOLERS 9, 1997, : 295 - 300
  • [34] Numerical and experimental study of a Gifford-McMahon-type pulse tube refrigerator
    Lu, GQ
    Cheng, P
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2003, 17 (04) : 457 - 463
  • [35] Experimental study on a double-orifice two-stage pulse tube refrigerator
    Chen, G
    Qiu, L
    Zheng, J
    Yan, P
    Gan, Z
    Bai, X
    Huang, Z
    CRYOGENICS, 1997, 37 (05) : 271 - 273
  • [36] Numerical simulation of a GM-type pulse tube cryocooler system: Part II. Rotary valve and cold head
    Liu, Dongli
    Dietrich, Marc
    Thummes, Guenter
    Gan, Zhihua
    CRYOGENICS, 2017, 81 : 100 - 106
  • [37] Experimental Investigation of a Single-Stage Four-Valve Pulse Tube Refrigerator
    王坤
    鲁雪生
    顾安忠
    Journal of Shanghai Jiaotong University, 2007, (01) : 96 - 99
  • [38] Analysis of DC Control in Double-inlet GM type Pulse Tube Refrigerators for Detectors
    Due, B. Y.
    INFRARED TECHNOLOGY AND APPLICATIONS, AND ROBOT SENSING AND ADVANCED CONTROL, 2016, 10157
  • [39] Experimental investigation of the connecting tube effect on a step displacer type two stage pulse tube refrigerator
    Lin, Yuzhe
    Guo, Zhaorui
    Guo, Zhimin
    Zhu, Shaowei
    APPLIED THERMAL ENGINEERING, 2020, 173 (173)
  • [40] Performance of a single-stage 4 K pulse tube cooler with neodymium regenerator precooled with a single-stage GM refrigerator
    von Schneidemesser, A
    Thummes, G
    Heiden, C
    CRYOGENICS, 1999, 39 (09) : 783 - 789