Novel high-efficiency 2D position-sensitive ZnS:Ag/6LiF scintillator detector for neutron diffraction

被引:2
|
作者
Mauri, Giacomo [1 ]
Sykora, G. Jeff [1 ]
Schooneveld, E. M. [1 ]
Capelli, S. C. [1 ]
Gutmann, M. J. [1 ]
Howarth, S. [1 ]
Mann, S. E. [1 ]
Zuddas, F. [1 ]
Rhodes, N. J. [1 ]
机构
[1] Sci & Technol Facil Council, Rutherford Appleton Lab, ISIS Neutron & Muon Source, Oxford OX11 0QX, England
来源
关键词
neutron detectors; neutron diffraction; scintillator detectors; SXD diffractometer; high efficiency; wavelength-shifting fibre detector; DIFFRACTOMETER;
D O I
10.1107/S1600576724002462
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Scintillator-based ZnS:Ag/(LiF)-Li-6 neutron detectors have been under development at ISIS for more than three decades. Continuous research and development aim to improve detector capabilities, achieve better performance and meet the increasingly demanding requirements set by neutron instruments. As part of this program, a high-efficiency 2D position-sensitive scintillator detector with wavelength-shifting fibres has been developed for neutron-diffraction applications. The detector consists of a double scintillator-fibre layer to improve detection efficiency. Each layer is made up of two orthogonal fibre planes placed between two ZnS:Ag/(LiF)-Li-6 scintillator screens. Thin reflective foils are attached to the front and back scintillators of each layer to minimize light cross-talk between layers. The detector has an active area of 192 x 192 mm with a square pixel size of 3 x 3 mm. As part of the development process of the double-layer detector, a single-layer detector was built, together with a prototype detector in which the two layers of the detector could be read out separately. Efficiency calculations and measurements of all three detectors are discussed. The novel double-layer detector has been installed and tested on the SXD diffractometer at ISIS. The detector performance is compared with the current scintillator detectors employed on SXD by studying reference crystal samples. More than a factor of 3 improvement in efficiency is achieved with the double-layer wavelength-shifting-fibre detector. Software routines for further optimizations in spatial resolution and uniformity of response have been implemented and tested for 2D detectors. The methods and results are discussed in this manuscript.
引用
收藏
页码:690 / 699
页数:10
相关论文
共 50 条
  • [21] Enhanced position resolution for ZnS:Ag/6LiF wavelength shifting fibre thermal neutron detectors
    Mauri, Giacomo
    Sykora, G. J.
    Schooneveld, E. M.
    Rhodes, N. J.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2021, 136 (03):
  • [22] High-position-resolution neutron imaging detector with crossed wavelength shifting fiber read-out using two ZnS/6LiF scintillator sheets
    Katagiri, M.
    Nakamura, T.
    Ebine, M.
    Birumachi, A.
    Sato, S.
    Shooneveld, E. M.
    Rhodes, N. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 149 - 152
  • [23] Detection of thermal neutrons using ZnS(Ag):6LiF neutron scintillator read out with WLS fibers and SiPMs
    Hildebrandt, M.
    Stoykov, A.
    Mosset, J. -B.
    Greuter, U.
    Schlumpf, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 204 - 207
  • [24] Simulation of the Neutron-Detection Efficiency and Resolution of a Scintillation Counter Based on ZnS(Ag) : 6LiF
    D. A. Buchnyy
    V. S. Litvin
    D. N. Trunov
    V. N. Marin
    S. N. Axenov
    R. A. Sadykov
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2022, 16 : 1121 - 1129
  • [25] Simulation of the Neutron-Detection Efficiency and Resolution of a Scintillation Counter Based on ZnS(Ag) : 6LiF
    Buchnyy, D. A.
    Litvin, V. S.
    Trunov, D. N.
    Marin, V. N.
    Axenov, S. N.
    Sadykov, R. A.
    JOURNAL OF SURFACE INVESTIGATION, 2022, 16 (06): : 1121 - 1129
  • [26] 2-D scintillation position-sensitive neutron detector
    De Lurgio, Patrick M.
    Farrar, Kelly A.
    Kreps, Andrew S.
    Madden, Timothy J.
    Naday, Istvan
    Weizeorick, John T.
    Hammonds, John P.
    Miller, Martha E.
    Schultz, Arthur J.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 648 - 653
  • [27] Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers
    Trunov, D. N.
    Marin, V. N.
    Sadykov, R. A.
    Altynbaev, E. V.
    Glushkova, T. I.
    JOURNAL OF SURFACE INVESTIGATION, 2024, 18 (04): : 881 - 886
  • [28] First investigation of a novel 2D position-sensitive semiconductor detector concept
    Bassignana, D.
    Fernandez, M.
    Jaramillo, R.
    Lozano, M.
    Munoz, F. J.
    Pellegrini, G.
    Quirion, D.
    Vila, I.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [29] Cold neutron radiation dose effects on a 6LiF:ZnS(Ag) neutron detector with wavelength shifting fibers and SiPM photodetector
    Pritchard, K.
    Hussey, D.
    Osovizky, A.
    Ziegler, J.
    Binkley, E.
    Tsai, P.
    Hadad, N.
    Jackson, M.
    Hurlbut, C.
    Baltic, G. M.
    Majkrzak, C. F.
    Maliszewskyj, N. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 986
  • [30] Coated Micro-Particle Simulations with 6LiF/ZnS(Ag) and 10B/ZnS(Ag) for Improved Neutron Detection Efficiency
    Logoglu, Faruk
    Wolfe, Douglas
    Flaska, Marek
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,