Energy consumption and thermal comfort of rock-cut and modern buildings

被引:1
|
作者
Mangeli, Mohammad [1 ]
Aram, Farshid [1 ]
Abouei, Reza [2 ]
机构
[1] Urmia Univ, Fac Architecture Urbanism & Art, Orumiyeh 5756151818, Iran
[2] Yazd Univ, Fac Art & Architecture, Yazd 8915818411, Iran
关键词
Indoor thermal comfort; Energy consumption; Rock-cut architecture; Meymand; Vernacular architecture; ENVIRONMENTS; DWELLINGS;
D O I
10.1016/j.heliyon.2024.e34217
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Energy consumption in the building sector justifies the necessity of knowing the thermal comfort perception of vernacular and modern architectural types, based on which a correct recognition was reached for the design of buildings suitable for the climatic conditions of each region. It should be determined that the different types of modern and traditional architecture are in the comfort level in harsh hot climate conditions and how much energy they consume to reach the comfort level. Despite consideration of energy consumption and thermal comfort in different buildings in Iran, there is no clear framework for evaluating these two parameters in different buildings and comparing them. This research aims to compare the indoor thermal comfort levels of vernacular architectural buildings and modern buildings in Iran's semi-hot and dry climate at the peak of summer heat and determine their energy consumption to reach the comfort level. This study has been accomplished by collecting field data, examining the indoor predicted mean vote (PMV) index of the buildings, and comparing them. It was found that rock-cut architecture buildings are in better thermal comfort conditions without energy consumption due to the use of groundmass temperature and low heat exchanges between the indoors and outdoors because of the thermal phase of the materials and the thickness of its layers. The indoor PMV average of rock-cut buildings in summer is -0.61; in modern buildings, it is 0.77, while these two building complexes are in the same climate and close. Also, the energy consumption to reach the comfort level in rock-cut buildings is zero, while modern buildings consume an average of 7.7 kW of electricity daily. The research results will lead to recognizing and modeling the climate design of vernacular architecture, which can be used in today's architecture to reduce energy consumption.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Effect of Architectural Building Design Parameters on Thermal Comfort and Energy Consumption in Higher Education Buildings
    Alghamdi, Salah
    Tang, Waiching
    Kanjanabootra, Sittimont
    Alterman, Dariusz
    BUILDINGS, 2022, 12 (03)
  • [32] Effects of future climate change on the preservation of artworks, thermal comfort and energy consumption in historic buildings
    Munoz Gonzalez, C. Ma
    Leon Rodriguez, A. L.
    Suarez Medina, R.
    Ruiz Jaramillo, J.
    APPLIED ENERGY, 2020, 276 (276)
  • [33] Balancing Thermal Comfort and Energy Consumption in Residential Buildings of Desert Areas: Impact of Passive Strategies
    Khechiba, Abir
    Djaghrouri, Djamila
    Benabbas, Moussadek
    Leccese, Francesco
    Rocca, Michele
    Salvadori, Giacomo
    SUSTAINABILITY, 2023, 15 (10)
  • [34] Rock-cut Tombs at the Asarbasi Settlement, Eurymedon Valley
    Doku, F. Eray
    OLBA, 2011, 19 : 127 - 158
  • [35] The Origin of Stepped Rock-Cut Tunnels in Eastern Anatolia
    Koroglu, Kemalettin
    Danismaz, Harun
    ANCIENT NEAR EASTERN STUDIES, 2018, 55 : 107 - 124
  • [36] Notes on the Rock-Cut 'Space' near the Gihon Spring
    Reich, Ronny
    TEL AVIV-JOURNAL OF THE INSTITUTE OF ARCHAEOLOGY OF TEL AVIV UNIVERSITY, 2021, 48 (02): : 199 - 207
  • [37] Research on indoor thermal comfort and energy consumption of zero energy wooden structure buildings in severe cold zone
    Ni, Shenyang
    Zhu, Neng
    Hou, Yingzhen
    Zhang, Zhiyuan
    JOURNAL OF BUILDING ENGINEERING, 2023, 67
  • [38] COMFORT AND ENERGY-CONSUMPTION ANALYSIS IN BUILDINGS WITH RADIANT PANELS
    CHEN, QY
    ENERGY AND BUILDINGS, 1990, 14 (04) : 287 - 297
  • [39] How Petra was built: an analysis of the construction techniques of the Nabataean freestanding buildings and rock-cut monuments in Petra, Jordan
    不详
    URBAN MORPHOLOGY, 2007, 11 (01): : 73 - 73
  • [40] Energy efficiency and thermal comfort in historic buildings: A review
    Martinez-Molina, Antonio
    Tort-Ausina, Isabel
    Cho, Soolyeon
    Vivancos, Jose-Luis
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 61 : 70 - 85