Atmospheric carbon dioxide profile detection with a continuous-wave differential absorption lidar

被引:0
|
作者
Hua, Zhenzhen [1 ,2 ,3 ]
Huang, Jian [2 ,3 ]
Shi, Dongfeng [2 ,3 ]
Yuan, Kee [2 ,3 ]
Hu, Shunxing [2 ,3 ]
Wang, Yingjian [1 ,2 ,3 ]
机构
[1] Univ Sci & Technol China, Sch Environm Sci & Optoelect Technol, Hefei 230026, Peoples R China
[2] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei Inst Phys Sci, Key Lab Atmospher Opt, Hefei 230031, Peoples R China
[3] Adv Laser Technol Lab Anhui Prov, Hefei 230037, Peoples R China
关键词
Differential absorption lidar (DIAL); Carbon dioxide (CO 2 ); Scheimpflug imaging principle; OPTICAL PARAMETRIC OSCILLATOR; CO2; CONCENTRATION; DIAL MEASUREMENT; SYSTEM; SENSITIVITY; 1.57-MU-M; RETRIEVAL; NO2;
D O I
10.1016/j.optlaseng.2024.108340
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Differential absorption Lidar (DIAL) is a powerful technique for remote sensing of atmospheric carbon dioxide (CO2). After decades of continuous evolution, traditional pulsed-based CO2 DIAL has made great progress and gradually comes into applications, but unfortunately these setups still face some dilemmas, such as complex structure, high cost, and poor maintainability. These inherent defects hinder the large-scale promotion application of traditional pulsed-based CO2 DIAL. Here, we demonstrated a 1.57 mu m continuous-wave differential absorption lidar (CW-DIAL) for atmospheric CO2 profile detection based on the Scheimpflug principle with a high dynamic range near-infrared (SWIR) array detector. A tunable SWIR distributed-feedback (DFB) laser is used as the seed light source, feeds to a self-made erbium-ytterbium co-doped fiber amplifier and obtain final output power to about 3 W of 1.57 mu m. A reflective telescope is employed to collect the atmospheric backscattered signal which is finally shapely imaged in a high dynamic range InGaAs array detector. Multiple atmospheric CO2 profiles were obtained over 3000 m with a cumulative measurement time of 2010s and a range resolution of 100 m. The detection results were also compared with a CO2 Sensor (GMP343), yielding a correlation coefficient of 0.99962 and a relative error of 1 %. The preliminary results confirm our developed CW-DIAL has the ability to detect the spatiotemporal distribution of atmospheric CO2. Given its compact structure, low power consumption and cost, it has enormous potential application in many areas for the range-resolved CO2 concentration profiles detection.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Minimization of systematic errors at lidar profile restitution of a atmospheric gas concentrations by the differential absorption method
    Romanovskii, OA
    TWELFTH JOINT INTERNATIONAL SYMPOSIUM ON ATMOSPHERIC AND OCEAN OPTICS/ATMOSPHERIC PHYSICS, PTS 1 AND 2, 2005, 6160
  • [32] DEVELOPMENT OF DIFFERENTIAL ABSORPTION LIDAR SYSTEM AT 1.57 μm FOR SENSING CARBON DIOXIDE IN CHINA
    Liang, Ailin
    Han, Ge
    Ma, Xin
    Xiang, Chengzhi
    Zheng, Yuxin
    Zhang, Teng
    Xu, Hao
    Gong, Wei
    2017 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2017, : 5268 - 5271
  • [33] Continuous-wave light detection and ranging (LiDAR) using image-reject homodyne detection and PRBS modulation
    Ward, Katie A. P.
    Spollard, James T.
    Roberts, Lyle E.
    McClelland, David C.
    Shaddock, Daniel A.
    AOS AUSTRALIAN CONFERENCE ON OPTICAL FIBRE TECHNOLOGY (ACOFT) AND AUSTRALIAN CONFERENCE ON OPTICS, LASERS, AND SPECTROSCOPY (ACOLS) 2019, 2019, 11200
  • [34] Range-resolved atmospheric aerosol monitoring by a Scheimpflug lidar system based on a continuous-wave laser diode
    Guan, Peng
    Mei, Liang
    2016 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2016,
  • [35] ATMOSPHERIC MERCURY IN CHINA STUDIED WITH DIFFERENTIAL ABSORPTION LIDAR
    Zhao, Guangyu
    Duan, Zheng
    Lian, Ming
    Svanberg, Sune
    29TH INTERNATIONAL LASER RADAR CONFERENCE (ILRC 29), 2020, 237
  • [36] Double-pulse 2-μm integrated path differential absorption lidar airborne validation for atmospheric carbon dioxide measurement
    Refaat, Tamer F.
    Singh, Upendra N.
    Yu, Jirong
    Petros, Mulugeta
    Remus, Ruben
    Ismail, Syed
    APPLIED OPTICS, 2016, 55 (15) : 4232 - 4246
  • [37] Differential absorption lidar for the measurements of atmospheric minor constituents
    Jain, SL
    Arya, BC
    Kumar, A
    22ND INTERNATIONAL LASER RADAR CONFERENCE (ILRC 2004), VOLS 1 AND 2, 2004, 561 : 713 - 716
  • [38] ERRORS IN LIDAR MEASUREMENT OF ATMOSPHERIC GASES BY DIFFERENTIAL ABSORPTION
    SCHOTLAND, RM
    JOURNAL OF APPLIED METEOROLOGY, 1974, 13 (01): : 71 - 77
  • [39] Continuous-wave quantum cascade lasers absorption spectrometers for trace gas detection in the atmosphere
    Joly, L.
    Zeninari, V.
    Decarpenterie, T.
    Cousin, J.
    Grouiez, B.
    Mammez, D.
    Durry, G.
    Carras, M.
    Marcadet, X.
    Parvitte, B.
    LASER PHYSICS, 2011, 21 (04) : 805 - 812
  • [40] Research on Continuous-wave Terahertz Radiation Detection
    Zhang Min
    Ruan Shuang-Chen
    Yang Jun
    Liu Wen-Quan
    2008 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS, VOLS 1-4, 2008, : 206 - +