Effect of trabecular architectures on the mechanical response in osteoporotic and healthy human bone

被引:5
|
作者
Bregoli, Chiara [1 ,2 ]
Biffi, Carlo Alberto [1 ]
Tuissi, Ausonio [1 ]
Buccino, Federica [2 ,3 ]
机构
[1] CNR, CNR ICMTE, Lecce, Italy
[2] Politecn Milan, Mech Engn Dept, Milan, Italy
[3] IRCCS Ist Ortoped Galeazzi, Milan, Italy
关键词
Human trabecular bone; Morphometric parameters; Mutual relationships; Bone mechanical behaviour; Computational mesoscale models; CANCELLOUS BONE; ELASTIC PROPERTIES; QUANTIFICATION; FEMUR;
D O I
10.1007/s11517-024-03134-8
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Research at the mesoscale bone trabeculae arrangement yields intriguing results that, due to their clinical resolution, can be applied in clinical field, contributing significantly to the diagnosis of bone-related diseases. While the literature offers quantitative morphometric parameters for a thorough characterization of the mesoscale bone network, there is a gap in understanding relationships among them, particularly in the context of various bone pathologies. This research aims to bridge these gaps by offering a quantitative evaluation of the interplay among morphometric parameters and mechanical response at mesoscale in osteoporotic and non-osteoporotic bones. Bone mechanical response, dependent on trabecular arrangement, is defined by apparent stiffness, computationally calculated using the Gibson-Ashby model. Key findings indicate that: (i) in addition to bone density, measured using X-ray absorptiometry, trabecular connectivity density, trabecular spacing and degree of anisotropy are crucial parameters for characterize osteoporosis state; (ii) apparent stiffness values exhibit strong correlations with bone density and connectivity density; (iii) connectivity density and degree of anisotropy result the best predictors of mechanical response. Despite the inherent heterogeneity in bone structure, suggesting the potential benefit of a larger sample size in the future, this approach presents a valuable method to enhance discrimination between osteoporotic and non-osteoporotic samples.
引用
收藏
页码:3263 / 3281
页数:19
相关论文
共 50 条
  • [41] The relation between mechanical stimulus and cell response in trabecular bone remodeling
    Dunlop, J. W. C.
    Hartmann, M. A.
    Brechet, Y.
    Fratzl, P.
    Weinkamer, R.
    CALCIFIED TISSUE INTERNATIONAL, 2007, 80 : S51 - S51
  • [42] Quantitative evaluation of trabecular bone structure by calcaneus MR images texture analysis of healthy volunteers and osteoporotic subjects
    Herlidou, S
    Idy-Peretti, I
    Grebe, R
    Grados, F
    Lecuyer, N
    Fardellone, P
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 2340 - 2342
  • [43] The structural response of trabecular bone to low-level mechanical stimuli
    Garman, R
    Rubin, C
    Judex, S
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 456 - 457
  • [44] Noninvasive assessment of trabecular bone structure of the distal radius in healthy postmenopausal and osteoporotic women using MR imaging
    Boutry, N
    Cortet, B
    Dubois, P
    Marchandise, X
    Cotten, A
    RADIOLOGY, 1998, 209P : 419 - 419
  • [45] Biomechanical effect of mineral heterogeneity in human trabecular bone
    Renders, G. A. P.
    Mulder, L.
    Langenbach, G. E. J.
    Van Ruijven, L. J.
    Koolstra, J. H.
    Van Eijden, T. M. G.
    BONE, 2009, 44 (02) : S258 - S258
  • [46] Evaluating the mechanical response of novel synthetic femurs for representing osteoporotic bone
    Gluek, Cooper
    Zdero, Radovan
    Quenneville, Cheryl E.
    JOURNAL OF BIOMECHANICS, 2020, 111
  • [47] Structural parameters of normal and osteoporotic human trabecular bone are affected differently by microCT image resolution
    Isaksson, H.
    Toyras, J.
    Hakulinen, M.
    Aula, A. S.
    Tamminen, I.
    Julkunen, P.
    Kroger, H.
    Jurvelin, J. S.
    OSTEOPOROSIS INTERNATIONAL, 2011, 22 (01) : 167 - 177
  • [48] Structural parameters of normal and osteoporotic human trabecular bone are affected differently by microCT image resolution
    H. Isaksson
    J. Töyräs
    M. Hakulinen
    A. S. Aula
    I. Tamminen
    P. Julkunen
    H. Kröger
    J. S. Jurvelin
    Osteoporosis International, 2011, 22 : 167 - 177
  • [49] Trabecular bone microarchitecture after alendronate treatment of osteoporotic women
    Recker, R
    Masarachia, P
    Santora, A
    Howard, T
    Chavassieux, P
    Arlot, M
    Rodan, G
    Wehren, L
    Kimmel, D
    CURRENT MEDICAL RESEARCH AND OPINION, 2005, 21 (02) : 185 - 194
  • [50] TRABECULAR BONE LOSS IN OSTEOPOROTIC WOMEN IS GENERALIZED AND NOT RESTRICTED TO THE SPINE
    GALLAGHER, JC
    GOLDGAR, D
    MAHONEY, P
    MCGILL, J
    CLINICAL RESEARCH, 1984, 32 (04): : A763 - A763