Measurement of Surface Potential of Non-uniformly Charged Insulating Materials Using a Non-contact Electrostatic Voltmeter

被引:2
|
作者
Fatihou, Ali [1 ]
Dascalescu, Lucian [1 ]
Zouzou, Noureddine [1 ]
Neagoe, Marius-Bogdan [1 ]
Reguig, Abdeljalil [1 ]
Dumitran, Laurentiu Marius [2 ]
机构
[1] Univ Poitiers, PPRIME Inst, CNRS, UPR 3346,ENSMA,IUT Angouleme, F-16021 Angouleme, France
[2] Univ Politehn Bucarest, Lab Electrotech Mat, Splaiul Independentei 313, Bucharest 060042, Romania
关键词
Electric charge; electrical potential; electrostatic measurements; electrostatic potential probe; electrostatic voltmeter; superficial charge simulation method; NONWOVEN FABRICS; DECAY; NEUTRALIZATION; INJECTION; STATE;
D O I
10.1109/TDEI.2016.005762
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Non-contact measurements performed with the auto-compensated electrostatic induction probe of an electrostatic voltmeter are often employed to characterize the charging state of insulating materials, such as films or non-woven media. The aim of the paper is double: (i) describe a simple method for assessing the resolution of such a probe; (ii) discuss the significance that can be attributed to the value displayed by the electrostatic voltmeter when the charge is non-uniformly distributed at the surface of the bodies examined by the probe and no constant surface potential can be defined. The measurements were performed for some simple experimental models that simulate surface potential non-uniformity of constant-charge insulating bodies. By examining the different surface potential distribution curves that were obtained for each of the situations under study, it is possible to estimate the resolution of the probe. A commercial computer program based on the superficial charge simulation method was employed for the numerical analysis of the electric field in a simplified 2-D representation of the geometric system formed by the probe, the experimental model, and the grounded plate. The potential that anneals the electric field at the surface of the probe (to simulate its principle of operation) was calculated by an iterative method. A good agreement was found between the results of the numerical simulations and the experimental data. The errors that can be made in the interpretation of the results of surface potential measurements are illustrated by the case of a non-uniformly-charged non-woven polypropylene fabric.
引用
收藏
页码:2377 / 2384
页数:8
相关论文
共 50 条
  • [31] Tribological measurement of the state of surface fabrics by a contact and a non-contact methods
    Bueno, MA
    Renner, M
    Durand, B
    MECHATRONICS '98, 1998, : 703 - 708
  • [32] NON-CONTACT STRIP SPEED MEASUREMENT USING AN ELECTROSTATIC SENSOR ARRAY AND DATA FUSION TECHNIQUE
    Wang Xiaoyu
    Hu Yonghui
    Qian Xiangchen
    Wang Lijuan
    Yan Yong
    2014 12TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP), 2014, : 363 - 367
  • [33] CAVE ROCK SURFACE TEMPERATURE EVALUATION USING NON-CONTACT MEASUREMENT METHODS
    Stredova, Hana
    Streda, Tomas
    Vysoudil, Miroslav
    ACTA CARSOLOGICA, 2014, 43 (2-3) : 257 - 268
  • [34] Comparison of Active Electrode Materials for Non-Contact ECG Measurement
    Peng, Shun
    Xu, Ke
    Chen, Wei
    SENSORS, 2019, 19 (16)
  • [35] Non-contact measurement of acoustic emission in materials by laser interferometry
    Enoki, M.
    Watanabe, M.
    Chivavibul, P.
    Kishi, T.
    SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2000, 1 (03) : 157 - 165
  • [36] Proposal of non-contact colorimetric measurement of materials in a closed space
    Isomi
    Sakai H.
    Iyota H.
    AIJ Journal of Technology and Design, 2021, 27 (67) : 1166 - 1170
  • [37] Electrophoretic trajectories of non-uniformly charged particles in viscoelastic fluids: the weak surface charge limit
    Borthakur, Rajnandan
    Ghosh, Uddipta
    JOURNAL OF FLUID MECHANICS, 2023, 954
  • [38] SKIN COLOUR MEASUREMENT BY USING NON-CONTACT METHODS
    Wang, M.
    Xiao, K.
    Wuerger, S.
    Liu, H. X.
    Huang, M.
    Luo, M. R.
    PROCEEDINGS OF CIE 2016 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2016, : 487 - 492
  • [39] Non-contact current measurement system using SQUID
    Odawara, A
    Nakayama, S
    Ikeda, M
    Morooka, T
    Nagata, A
    Tsuda, I
    Kasai, N
    Chinone, K
    PHYSICA B-CONDENSED MATTER, 2003, 329 : 1517 - 1518
  • [40] Non-contact measurement of eyeblink by using Doppler sensor
    Maleki, Amir
    Uchida, Masafumi
    ARTIFICIAL LIFE AND ROBOTICS, 2018, 23 (02) : 279 - 285