Outcomes and Predictors of Stroke After Transcatheter Aortic Valve Replacement in the Cerebral Protection Device Era

被引:1
|
作者
Shekhar, Shashank [1 ]
Isogai, Toshiaki [1 ]
Agrawal, Ankit [1 ]
Kaw, Roop [1 ]
Mahalwar, Gauranga [1 ]
Krishnaswamy, Amar [1 ]
Puri, Rishi [1 ]
Reed, Grant [1 ]
Mentias, Amgad [1 ]
Kapadia, Samir [1 ]
机构
[1] Cleveland Clin, Heart Vasc & Thorac Inst, Dept Cardiovasc Med, 9500 Euclid Ave,J2-3, Cleveland, OH 44195 USA
来源
关键词
cerebral embolic protection; sentinel device; stroke; TAVR; EMBOLIC PROTECTION; CEREBROVASCULAR EVENTS; TAVR; ASSOCIATION; STENOSIS;
D O I
10.1161/JAHA.124.034298
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Studies have shown inconclusive results on the effectiveness of cerebral protection devices (CPDs) with transcatheter aortic valve replacement. We aimed to analyze the national statistics on stroke and other outcomes with CPD use.Methods and Results The Nationwide Readmissions Database (2017-2020) was queried to obtain data on patients undergoing transcatheter aortic valve replacement. Outcomes were compared between patients with a CPD and patients without a CPD. Of 271 804 patients undergoing transcatheter aortic valve replacement, CPD was used in 7.3% of patients. In a multivariable logistic regression analysis, CPD use was not associated with lower overall stroke rates (1.6% versus 1.9% without CPD; odds ratio, 0.95 [95% CI, 0.84-1.07]; P=0.364), but it was significantly associated with lower major stroke rates (1.2% versus 1.5% without CPD; odds ratio, 0.85 [95% CI, 0.74-0.98]; P=0.02). Patients with a CPD also had a shorter length of stay, higher routine discharges to home/self-care (74.9% versus 70.6%), and lower mortality rates (0.7% versus 1.3%). The 30-day (9.6% versus 11.7%) and 180-day (24.6% versus 28.2%) readmission rates were significantly lower in the CPD cohort. Among patients who developed stroke, patients with a CPD had more frequent routine discharges. Prior valve surgery was associated with the highest risk of overall and major stroke.Conclusions CPD use during transcatheter aortic valve replacement was not independently associated with a lower risk of overall stroke but was associated with a lower risk of major stroke in a multivariable model. Data from future randomized trials that may offset any potential confounders in our study are required to help identify patients who would benefit from the use of these devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Trends in Inpatient Complications After Transcatheter and Surgical Aortic Valve Replacement in the Transcatheter Aortic Valve Replacement Era
    Arora, Sameer
    Strassle, Paula D.
    Qamar, Arman
    Kolte, Dhaval
    Pandey, Ambarish
    Paladugu, Madhu B.
    Borhade, Mahesh B.
    Ramm, Cassandra J.
    Bhatt, Deepak L.
    Vavalle, John P.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (11)
  • [22] Impact of Perioperative Stroke on Midterm Outcomes After Transcatheter Aortic Valve Replacement
    Habertheuer, Andreas
    Gleason, Thomas G.
    Kilic, Arman
    Schindler, John
    Kliner, Dustin
    Bianco, Valentino
    Toma, Catalin
    Aranda-Michel, Edgar
    Kacin, Alexa
    Sultan, Ibrahim
    ANNALS OF THORACIC SURGERY, 2020, 110 (04): : 1294 - 1301
  • [23] Transcatheter Mitral Valve Replacement in the Transcatheter Aortic Valve Replacement Era
    Testa, Luca
    Rubbio, Antonio Popolo
    Casenghi, Matteo
    Pero, Gaetano
    Latib, Azeem
    Bedogni, Francesco
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (22):
  • [24] Cerebral Embolic Protection During Transcatheter Aortic Valve Replacement
    Yashima, Fumiaki
    Briasoulis, Alexandros
    Kuno, Toshiki
    Noguchi, Masahiko
    Ahmad, Hasan
    Zaid, Syed
    Goldberg, Joshua B.
    Malik, Aaqib H.
    Tang, Gilbert H. L.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 36 : 9 - 13
  • [25] Cerebral embolic protection systems for transcatheter aortic valve replacement
    Gasior, Tomasz
    Mangner, Norman
    Bijoch, Julia
    Wojakowski, Wojciech
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2018, 31 (06) : 891 - 898
  • [26] Transcarotid transcatheter aortic valve replacement with cerebral embolic protection
    McGrath, Daniel
    Salehi, Payam
    Weintraub, Andrew
    Zhan, Yong
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (06) : 1779 - 1782
  • [27] Cerebral Events and Protection During Transcatheter Aortic Valve Replacement
    Freeman, Melanie
    Barbanti, Marco
    Wood, David A.
    Ye, Jian
    Webb, John G.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (06) : 885 - 896
  • [28] Association of Cerebral Embolic Protection Device Use With Disabling Stroke After Transcatheter Aortic Valve Replacement: Insights From the National Inpatient Sample
    Lipinski, Jerry
    Waldo, Stephen
    Kolte, Dhaval
    Yeh, Robert
    Cohen, David
    Butala, Neel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B347 - B348
  • [29] Hemodynamic Valve Deterioration After Transcatheter Aortic Valve Replacement Incidence, Predictors, and Clinical Outcomes
    Alaour, Bashir
    Tomii, Daijiro
    Nakase, Masaaki
    Heg, Dik
    Stortecky, Stefan
    Lanz, Jonas
    Samim, Daryoush
    Reineke, David
    Praz, Fabien
    Windecker, Stephan
    Pilgrim, Thomas
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 18 (01) : 72 - 85
  • [30] Predictors of Poor Outcomes After Transcatheter Aortic Valve Replacement Results From the PARTNER (Placement of Aortic Transcatheter Valve) Trial
    Arnold, Suzanne V.
    Reynolds, Matthew R.
    Lei, Yang
    Magnuson, Elizabeth A.
    Kirtane, Ajay J.
    Kodali, Susheel K.
    Zajarias, Alan
    Thourani, Vinod H.
    Green, Philip
    Rodes-Cabau, Josep
    Beohar, Nirat
    Mack, Michael J.
    Leon, Martin B.
    Cohen, David J.
    CIRCULATION, 2014, 129 (25) : 2682 - 2690