Outcomes and Predictors of Stroke After Transcatheter Aortic Valve Replacement in the Cerebral Protection Device Era

被引:1
|
作者
Shekhar, Shashank [1 ]
Isogai, Toshiaki [1 ]
Agrawal, Ankit [1 ]
Kaw, Roop [1 ]
Mahalwar, Gauranga [1 ]
Krishnaswamy, Amar [1 ]
Puri, Rishi [1 ]
Reed, Grant [1 ]
Mentias, Amgad [1 ]
Kapadia, Samir [1 ]
机构
[1] Cleveland Clin, Heart Vasc & Thorac Inst, Dept Cardiovasc Med, 9500 Euclid Ave,J2-3, Cleveland, OH 44195 USA
来源
关键词
cerebral embolic protection; sentinel device; stroke; TAVR; EMBOLIC PROTECTION; CEREBROVASCULAR EVENTS; TAVR; ASSOCIATION; STENOSIS;
D O I
10.1161/JAHA.124.034298
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Studies have shown inconclusive results on the effectiveness of cerebral protection devices (CPDs) with transcatheter aortic valve replacement. We aimed to analyze the national statistics on stroke and other outcomes with CPD use.Methods and Results The Nationwide Readmissions Database (2017-2020) was queried to obtain data on patients undergoing transcatheter aortic valve replacement. Outcomes were compared between patients with a CPD and patients without a CPD. Of 271 804 patients undergoing transcatheter aortic valve replacement, CPD was used in 7.3% of patients. In a multivariable logistic regression analysis, CPD use was not associated with lower overall stroke rates (1.6% versus 1.9% without CPD; odds ratio, 0.95 [95% CI, 0.84-1.07]; P=0.364), but it was significantly associated with lower major stroke rates (1.2% versus 1.5% without CPD; odds ratio, 0.85 [95% CI, 0.74-0.98]; P=0.02). Patients with a CPD also had a shorter length of stay, higher routine discharges to home/self-care (74.9% versus 70.6%), and lower mortality rates (0.7% versus 1.3%). The 30-day (9.6% versus 11.7%) and 180-day (24.6% versus 28.2%) readmission rates were significantly lower in the CPD cohort. Among patients who developed stroke, patients with a CPD had more frequent routine discharges. Prior valve surgery was associated with the highest risk of overall and major stroke.Conclusions CPD use during transcatheter aortic valve replacement was not independently associated with a lower risk of overall stroke but was associated with a lower risk of major stroke in a multivariable model. Data from future randomized trials that may offset any potential confounders in our study are required to help identify patients who would benefit from the use of these devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Predictors and outcomes of stroke after transcatheter aortic valve replacement
    Hatfield, Sarah A.
    Nores, Marcos A.
    James, Taylor M.
    Rothenberg, Mark
    Kapila, Arvind
    Cubeddu, Roberto J.
    Stamou, Sotiris C.
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (01) : 21 - 27
  • [2] When Sentinel is not enough: stroke after transcatheter aortic valve replacement with cerebral protection
    Yasuhiro Aoki
    Ramin S. Hastings
    Lance I. Kovar
    Adam Arnofsky
    Joseph De Gregorio
    Cardiovascular Intervention and Therapeutics, 2021, 36 : 400 - 401
  • [3] When Sentinel is not enough: stroke after transcatheter aortic valve replacement with cerebral protection
    Aoki, Yasuhiro
    Hastings, Ramin S.
    Kovar, Lance I.
    Arnofsky, Adam
    De Gregorio, Joseph
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2021, 36 (03) : 400 - 401
  • [4] Geometric Predictors of Stroke After Transcatheter Aortic Valve Replacement
    Vogl, Brennan
    Vitale, Emily
    Wang, Zhenyu
    Sularz, Agata
    Ponce, Alejandra Chavez
    Lo Russo, Gerardo V.
    Alarouri, Hasan S.
    Alkhouli, Mohamad
    Hatoum, Hoda
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B165 - B166
  • [5] Ischemic Stroke With Cerebral Protection System During Transcatheter Aortic Valve Replacement
    Megaly, Michael
    Sorajja, Paul
    Cavalcante, Joao
    Pershad, Ashish
    Goessl, Mario
    Abraham, Bishoy
    Elbadawi, Ayman
    Garcia, Santiago
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B3 - B4
  • [6] Ischemic Stroke With Cerebral Protection System During Transcatheter Aortic Valve Replacement
    Megaly, Michael
    Sorajja, Paul
    Cavalcante, Joao L.
    Pershad, Ashish
    Goessl, Mario
    Abraham, Bishoy
    Omer, Mohamed
    Elbadawi, Ayman
    Garcia, Santiago
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (18) : 2149 - 2155
  • [7] Cerebral embolic protection and severity of stroke following transcatheter aortic valve replacement
    Isogai, Toshiaki
    Vanguru, Husitha Reddy
    Krishnaswamy, Amar
    Agrawal, Ankit
    Spilias, Nikolaos
    Shekhar, Shashank
    Saad, Anas M.
    Verma, Beni Rai
    Puri, Rishi
    Reed, Grant W.
    Popovic, Zoran B.
    Unai, Shinya
    Yun, James J.
    Uchino, Ken
    Kapadia, Samir R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 100 (05) : 810 - 820
  • [8] Cerebral embolic protection for stroke prevention during transcatheter aortic valve replacement
    Basit, Jawad
    Ahmed, Mushood
    Kidess, George
    Zaheer, Zaofashan
    Fatima, Laveeza
    Naveed, Hamza
    Hamza, Mohammad
    Fatima, Maurish
    Goyal, Aman
    Loyalka, Pranav
    Alam, Mahboob
    Alraies, M. Chadi
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2024, 22 (08) : 409 - 420
  • [9] Outcomes of Cerebral Embolic Protection for Bicuspid Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Replacement
    Zhang, Jiajun
    Li, Xiaoxing
    Tian, Rui
    Zong, Mengzhi
    Gu, Xinghua
    Xu, Feng
    Chen, Yuguo
    Li, Chuanbao
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (12):
  • [10] Cerebral protection devices for transcatheter aortic valve replacement
    Cubero-Gallego, Hector
    Pascual, Isaac
    Rozado, Jose
    Ayesta, Ana
    Hernandez-Vaquero, Daniel
    Diaz, Rocio
    Alperi, Alberto
    Avanzas, Pablo
    Moris, Cesar
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (20)