Determination of masseter and temporal muscle thickness by ultrasound and muscle hardness by shear wave elastography in healthy adults as reference values

被引:6
|
作者
Koruyucu, Ayse Nur [1 ,2 ]
Asantogrol, Firdevs [1 ]
机构
[1] Gaziantep Univ, Fac Dent, Dept Oral & Maxillofacial Radiol, TR-27310 Gaziantep, Turkiye
[2] Gaziantep Univ, Fac Dent, Dept Oral & Maxillofacial Radiol, Osmangazi St,Univ Blvd, TR-27310 Sehitkamil Gaziantep, Turkiye
关键词
ultrasonography; shear wave elastography; masseter muscle; temporal muscle; reference values; SONOGRAPHIC ELASTOGRAPHY; ULTRASONOGRAPHY; PERFORMANCE; ELASTICITY; SARCOPENIA; MEN;
D O I
10.1093/dmfr/twad013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this study is to prospectively investigate the reference values of masseter and temporal muscle thicknesses by ultrasonography and muscle hardness values by shear wave elastography in healthy adults. Methods: The sample of the study consisted of a total of 160 healthy individuals aged between 18 and 59, including 80 women and 80 men. By examining the right and left sides of each participant, thickness and hardness values were obtained for 320 masseter muscles and 320 temporal muscles in total. Results: The mean masseter muscle thickness was found to be 1.09 cm at rest and 1.40 cm in contraction. The mean temporal muscle thickness was found to be 0.88 cm at rest and 0.98 cm in contraction. The thickness values of the masseter and temporal muscles were significantly greater in the male participants than in the female participants (P < .001). While there were significant differences between the right and left masseter muscle thickness values at rest and in contraction, the values of the temporal muscles did not show a significant difference between the sides. While the resting hardness (rSWE) of the masseter muscle was transversally 6.91 kPa and longitudinally 8.49 kPa, these values in contraction (cSWE) were found, respectively, 31.40 and 35.65 kPa. The median temporal muscle hardness values were 8.84 kPa at rest and 20.43 kPa in contraction. Masseter and temporal muscle hardness values at rest and in contraction were significantly higher among the male participants compared to the female participants (P < .001). Conclusion: In this study, reference values for the thickness and hardness of the masseter and temporal muscles are reported. Knowing these values will make it easier to assess pain in the masseter and temporal muscles and determine the diagnosis and prognosis of masticatory muscle pathologies by allowing the morphological and functional assessments of these muscles, and it will identify ranges for reference parameters.
引用
收藏
页码:137 / 152
页数:16
相关论文
共 50 条
  • [21] Comparison of rectus femoris muscle shear wave elastography and thickness on evaluation of frailty
    Fadiloglu, Ayse
    Cataltepe, Esra
    Ceker, Eda
    Allahverdiyeva, Seriyye
    Samadli, Seymur
    Sendur, Halit Nahit
    Gungor, Fatih
    Varan, Hacer Dogan
    EUROPEAN GERIATRIC MEDICINE, 2025, 16 (01) : 183 - 190
  • [22] Shear-wave elastography of the testis in the healthy man - determination of standard values
    Trottmann, M.
    Marcon, J.
    D'Anastasi, M.
    Bruce, M. F.
    Stief, C. G.
    Reiser, M. F.
    Buchner, A.
    Clevert, D. A.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2016, 62 (03) : 273 - 281
  • [23] Adductor pollicis muscle: Reference values of its thickness in a healthy population
    Gonzalez, M. Cristina
    Duarte, Rodrigo R. P.
    Budziareck, Michele B.
    CLINICAL NUTRITION, 2010, 29 (02) : 268 - 271
  • [24] Delayed-Onset Muscle Soreness: Temporal Assessment With Quantitative MRI and Shear-Wave Ultrasound Elastography
    Agten, Christoph A.
    Buck, Florian M.
    Dyer, Linda
    Fluck, Martin
    Pfirrmann, Christian W. A.
    Rosskopf, Andrea B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (02) : 402 - 412
  • [25] Use of shear wave ultrasound elastography to quantify muscle properties in cerebral palsy
    Lee, Sabrina S. M.
    Gaebler-Spira, Deborah
    Zhang, Li-Qun
    Rymer, William Z.
    Steele, Katherine M.
    CLINICAL BIOMECHANICS, 2016, 31 : 20 - 28
  • [26] Muscle Ultrasound Shear Wave Elastography as a Non-Invasive Biomarker in Myotonia
    Kronlage, Cornelius
    Grimm, Alexander
    Romano, Alyssa
    Stahl, Jan-Hendrik
    Martin, Pascal
    Winter, Natalie
    Marquetand, Justus
    DIAGNOSTICS, 2021, 11 (02)
  • [27] Ultrasound shear wave elastography in assessment of skeletal muscle stiffness in senior volunteers
    Phan, Andrew
    Lee, Juhyun
    Gao, Jing
    CLINICAL IMAGING, 2019, 58 : 22 - 26
  • [28] Establishing Normal Values for Shear-Wave Elastography of the Renal Cortex in Healthy Adults
    Sandhu, Ranjit S.
    Shin, James
    Wehrli, Natasha E.
    Gao, Jing
    JOURNAL OF MEDICAL ULTRASOUND, 2018, 26 (02) : 81 - 84
  • [29] Assessment of the masseter stiffness in patients during conservative therapy for masticatory muscle disorders with shear wave elastography
    Anna Olchowy
    Piotr Seweryn
    Cyprian Olchowy
    Mieszko Wieckiewicz
    BMC Musculoskeletal Disorders, 23
  • [30] Assessment of the masseter stiffness in patients during conservative therapy for masticatory muscle disorders with shear wave elastography
    Olchowy, Anna
    Seweryn, Piotr
    Olchowy, Cyprian
    Wieckiewicz, Mieszko
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)