An assessment of the ageing of the absolute spectral responsivity of trap detectors at krypton ion laser emission wavelengths

被引:0
|
作者
Dury, Martin [1 ]
Harris, Subrena [1 ]
Goodman, Teresa [1 ]
Servantes, William [1 ]
White, Malcolm [2 ,3 ]
机构
[1] Natl Phys Lab, Opt Radiometr Metrol Grp, Teddington, England
[2] Univ Colorado, Dept Phys, Boulder, CO 80309 USA
[3] Natl Inst Stand & Technol, Boulder, CO 80305 USA
关键词
radiometry; responsivity; cryogenic radiometer; trap detector;
D O I
10.1088/1681-7575/ad615d
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have assessed the absolute spectral responsivities of three-element trap detectors calibrated against the National Physical Laboratory primary standard cryogenic radiometer at eight krypton ion laser emission wavelengths over an approximate period of 20 years. As expected, we observed that the absolute spectral responsivities decrease with time. Additionally, we found that as the wavelength decreases, the ageing rate increases. At 356.4 nm, an average responsivity decrease of around -1800 ppm yr-1 is reported. While at longer wavelengths, the slowest rate of ageing, approximately -40 ppm yr-1, occurs at 799.3 nm. Interestingly, the year-on-year changes exhibit a relatively linear trend, allowing us to predict the future performance of the trap detectors. It is important to note, however, that predicted performance cannot be guaranteed and regular recalibration against a primary standard is essential, especially if low calibration uncertainties are required.
引用
收藏
页数:9
相关论文
共 42 条
  • [31] Spectral and ion emission features of laser-produced Sn and SnO2 plasmas
    Lan, Hui
    Wang, Xin-Bing
    Zuo, Du-Luo
    CHINESE PHYSICS B, 2016, 25 (03)
  • [32] Application of single-crystal CVD diamond and SiC detectors for diagnostics of ion emission from laser plasmas
    Ryc, L.
    Calcagno, L.
    Dubecky, F.
    Margarone, D.
    Nowak, T.
    Parys, P.
    Pfeifer, M.
    Riesz, F.
    Torrisi, L.
    NINTH INTERNATIONAL CONFERENCE ON ADVANCED SEMICONDUCTOR DEVICES AND MICROSYSTEMS, 2012, : 255 - 258
  • [33] Studies of ion emission from plasmas generated by the high-energy pals laser at 1.315 μm and 0.438 μm wavelengths
    Wolowski, J
    Badziak, J
    Parys, P
    Woryna, E
    Boody, FP
    Gammino, S
    Hora, H
    Jungwirth, K
    Krása, J
    Láska, L
    Pfeifer, M
    Rohlena, K
    Szydlowski, A
    Torrisi, L
    Ullschmied, J
    PLASMA: PRODUCTION BY LASER ABLATION, 2004, : 82 - 89
  • [34] Comparison of EUV spectral and ion emission features from laser-produced Sn and Li plasmas
    Coons, R. W.
    Campos, D.
    Crank, M.
    Harilal, S. S.
    Hassanein, A.
    EXTREME ULTRAVIOLET (EUV) LITHOGRAPHY, 2010, 7636
  • [35] Monochromatic Radiation Source Based on a Supercontinuum Laser for Measurement of Spectral Sensitivity of Radiation Detectors in the Range 0.9–1.6 μm with the Use of an Absolute Cryogenic Radiometer
    A. Yu. Dunaev
    A. S. Baturin
    V. N. Krutikov
    S. P. Morozova
    Measurement Techniques, 2021, 63 : 877 - 882
  • [36] Evaluation of wavelengths and spectral reflectance indices for high-throughput assessment of growth, water relations and ion contents of wheat irrigated with saline water
    El-Hendawy, Salah E.
    Al-Suhaibani, Nasser A.
    Hassan, Wael M.
    Dewir, Yaser H.
    Elsayed, Salah
    Al-Ashkar, Ibrahim
    Abdella, Kamel A.
    Schmidhalter, Urs
    AGRICULTURAL WATER MANAGEMENT, 2019, 212 : 358 - 377
  • [37] CHANGE OF VALUES OF ABSOLUTE CROSS-SECTIONS OF EMISSION OF SPECTRAL-LINES DURING SLOW K+ ION COLLISIONS WITH HE ATOMS
    GOCHITASHVILI, MR
    KVIZHINADZE, RV
    DZHALIASHVILI, NR
    KIKIANI, BI
    ZHURNAL TEKHNICHESKOI FIZIKI, 1992, 62 (10): : 27 - 34
  • [38] Spectral dips in ion emission emerging from ultrashort laser-driven plasmas -: art. no. 155006
    Ter-Avetisyan, S
    Schnürer, M
    Busch, S
    Risse, E
    Nickles, PV
    Sandner, W
    PHYSICAL REVIEW LETTERS, 2004, 93 (15) : 155006 - 1
  • [39] Monochromatic Radiation Source Based on a Supercontinuum Laser for Measurement of Spectral Sensitivity of Radiation Detectors in the Range 0.9-1.6 μm with the Use of an Absolute Cryogenic Radiometer
    Dunaev, A. Yu
    Baturin, A. S.
    Krutikov, V. N.
    Morozova, S. P.
    MEASUREMENT TECHNIQUES, 2021, 63 (11) : 877 - 882
  • [40] Study of the effect of emission reabsorption in spectral lines on the value of amplification coefficient on Li-like ion transitions in recombination laser plasma
    Godunov, AL
    Makhrov, VA
    Sechin, AY
    Starostin, AN
    Stepanov, AE
    ZHURNAL EKSPERIMENTALNOI I TEORETICHESKOI FIZIKI, 1996, 109 (06): : 2064 - 2077