Ultra-High-Resolution T2-Weighted PROPELLER MRI of the Rectum With Deep Learning Reconstruction Assessment of Image Quality and Diagnostic Performance

被引:4
|
作者
Matsumoto, Shohei [1 ]
Tsuboyama, Takahiro [1 ,5 ]
Onishi, Hiromitsu [1 ]
Fukui, Hideyuki [1 ]
Honda, Toru [1 ]
Wakayama, Tetsuya [2 ]
Wang, Xinzeng [3 ]
Matsui, Takahiro [4 ]
Nakamoto, Atsushi [1 ]
Ota, Takashi [1 ]
Kiso, Kengo [1 ]
Osawa, Kana [1 ]
Tomiyama, Noriyuki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Radiol, Osaka, Japan
[2] GE Healthcare, MR Collaborat & Dev, Tokyo, Japan
[3] GE Healthcare, MR Collaborat & Dev, Austin, TX USA
[4] Osaka Univ, Grad Sch Med, Dept Pathol, Osaka, Japan
[5] Osaka Univ, Grad Sch Med, Dept Radiol, 2-2 Yamadaoka, Suita, Osaka 5650871, Japan
关键词
magnetic resonance imaging; T2-weighted imaging; periodically rotated overlapping parallel lines with enhanced reconstruction; deep learning reconstruction; ultra-high-resolution acquisition; rectal cancer; EXTRAMURAL VENOUS INVASION; VASCULAR INVASION; CANCER;
D O I
10.1097/RLI.0000000000001047
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to evaluate the impact of ultra-high-resolution acquisition and deep learning reconstruction (DLR) on the image quality and diagnostic performance of T2-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) imaging of the rectum. Materials and Methods: This prospective study included 34 patients who underwent magnetic resonance imaging (MRI) for initial staging or restaging of rectal tumors. The following 4 types of oblique axial PROPELLER images perpendicular to the tumor were obtained: a standard 3-mm slice thickness with conventional reconstruction (3-CR) and DLR (3-DLR), and 1.2-mm slice thickness with CR (1.2-CR) and DLR (1.2-DLR). Three radiologists independently evaluated the image quality and tumor extent by using a 5-point scoring system. Diagnostic accuracy was evaluated in 22 patients with rectal cancer who underwent surgery after MRI without additional neoadjuvant therapy (median interval between MRI and surgery, 22 days). The signal-to-noise ratio and tissue contrast were measured on the 4 types of PROPELLER imaging. Results: 1.2-DLR imaging showed the best sharpness, overall image quality, and rectal and lesion conspicuity for all readers (P < 0.01). Of the assigned scores for tumor extent, extramural venous invasion (EMVI) scores showed moderate agreement across the 4 types of PROPELLER sequences in all readers (intraclass correlation coefficient, 0.60-0.71). Compared with 3-CR imaging, the number of cases with MRI-detected extramural tumor spread was significantly higher with 1.2-DLR imaging (19.0 +/- 2.9 vs 23.3 +/- 0.9, P = 0.03), and the number of cases with MRI-detected EMVI was significantly increased with 1.2-CR, 3-DLR, and 1.2-DLR imaging (8.0 +/- 0.0 vs 9.7 +/- 0.5, 11.0 +/- 2.2, and 12.3 +/- 1.7, respectively; P = 0.02). For the diagnosis of histopathologic extramural tumor spread, 3-CR and 1.2-CR had significantly higher specificity than 3-DLR and 1.2-DLR imaging (0.75 and 0.78 vs 0.64 and 0.58, respectively; P = 0.02), and only 1.2-CR had significantly higher accuracy than 3-CR imaging (0.83 vs 0.79, P = 0.01). The accuracy of MRI-detected EMVI with reference to pathological EMVI was significantly lower for 3-CR and 3-DLR compared with 1.2-CR (0.77 and 0.74 vs 0.85, respectively; P < 0.01), and was not significantly different between 1.2-CR and 1.2-DLR (0.85 vs 0.80). Using any pathological venous invasion as the reference standard, the accuracy of MRI-detected EMVI was significantly the highest with 1.2-DLR, followed by 1.2-CR, 3-CR, and 3-DLR (0.71 vs 0.67 vs 0.59 vs 0.56, respectively; P < 0.01). The signal-to-noise ratio was significantly highest with 3-DLR imaging (P < 0.05). There were no significant differences in tumor-to-muscle contrast between the 4 types of PROPELLER imaging. Conclusions: Ultra-high-resolution PROPELLER T2-weighted imaging of the rectum combined with DLR improved image quality, increased the number of cases with MRI-detected extramural tumor spread and EMVI, but did not improve diagnostic accuracy with respect to pathology in rectal cancer, possibly because of false-positive MRI findings or false-negative pathologic findings.
引用
收藏
页码:479 / 488
页数:10
相关论文
共 50 条
  • [31] Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T
    Yang, Fan
    Pan, Xuelin
    Zhu, Ke
    Xiao, Yitian
    Yue, Xun
    Peng, Pengfei
    Zhang, Xiaoyong
    Huang, Juan
    Chen, Jie
    Yuan, Yuan
    Sun, Jiayu
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 156
  • [32] Performance of PROPELLER relative to standard FSE T2-weighted imaging in pediatric brain MRI
    Vertinsky, A. Talia
    Rubesova, Erika
    Krasnokutsky, Michael V.
    Bammer, Sabine
    Rosenberg, Jarrett
    White, Allan
    Barnes, Patrick D.
    Bammer, Roland
    PEDIATRIC RADIOLOGY, 2009, 39 (10) : 1038 - 1047
  • [33] Image Quality and Diagnostic Performance of Accelerated Shoulder MRI With Deep Learning-Based Reconstruction
    Hahn, Seok
    Yi, Jisook
    Lee, Ho-Joon
    Lee, Yedaun
    Lim, Yun-Jung
    Bang, Jin-Young
    Kim, Hyunwoong
    Lee, Joonsung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (03) : 506 - 516
  • [34] Performance of PROPELLER relative to standard FSE T2-weighted imaging in pediatric brain MRI
    A. Talia Vertinsky
    Erika Rubesova
    Michael V. Krasnokutsky
    Sabine Bammer
    Jarrett Rosenberg
    Allan White
    Patrick D. Barnes
    Roland Bammer
    Pediatric Radiology, 2009, 39 : 1038 - 1047
  • [35] Accelerated T2-weighted MRI of the liver at 3 T using a single-shot technique with deep learning-based image reconstruction: impact on the image quality and lesion detection
    Luke A. Ginocchio
    Paul N. Smereka
    Angela Tong
    Vinay Prabhu
    Dominik Nickel
    Simon Arberet
    Hersh Chandarana
    Krishna P. Shanbhogue
    Abdominal Radiology, 2023, 48 : 282 - 290
  • [36] Accelerated T2-weighted MRI of the liver at 3 T using a single-shot technique with deep learning-based image reconstruction: impact on the image quality and lesion detection
    Ginocchio, Luke A.
    Smereka, Paul N.
    Tong, Angela
    Prabhu, Vinay
    Nickel, Dominik
    Arberet, Simon
    Chandarana, Hersh
    Shanbhogue, Krishna P.
    ABDOMINAL RADIOLOGY, 2023, 48 (01) : 282 - 290
  • [37] Ultra-high-resolution CT urography: Importance of matrix size and reconstruction technique on image quality
    Nakamoto, Atsushi
    Hori, Masatoshi
    Onishi, Hiromitsu
    Ota, Takashi
    Fukui, Hideyuki
    Ogawa, Kazuya
    Yano, Keigo
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 130
  • [38] Deep learning-accelerated T2-weighted imaging of the prostate: Impact of further acceleration with lower spatial resolution on image quality
    Kim, Eu Hyun
    Choi, Moon Hyung
    Lee, Young Joon
    Han, Dongyeob
    Mostapha, Mahmoud
    Nickel, Dominik
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 145
  • [39] Accelerated T2-weighted MRI of the Bowel at 3T Using a Single-shot Technique with Deep Learning-based Image Reconstruction: Impact on Image Quality and Disease Detection
    Dane, Bari
    Bagga, Barun
    Bansal, Bhavik
    Beier, Sarah
    Kim, Sooah
    Reddy, Arthi
    Fenty, Felicia
    Keerthivasan, Mahesh
    Chandarana, Hersh
    ACADEMIC RADIOLOGY, 2025, 32 (01) : 210 - 217
  • [40] Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT (10.1007/s00330-019-06170-3, 2019)
    Akagi, Motonori
    Nakamura, Yuko
    Higaki, Toru
    Narita, Keigo
    Honda, Yukiko
    Zhou, Jian
    Yu, Zhou
    Akino, Naruomi
    Awai, Kazuo
    EUROPEAN RADIOLOGY, 2019, 29 (08) : 4526 - 4527