Structural Investigation of Shear Performance of Square CFST Column Joints with Extended Hollo-Bolts

被引:1
|
作者
Debnath, Partha Pratim [1 ]
Chan, Tak-Ming [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hung Hom, Kowloon, Hong Kong, Peoples R China
关键词
Concrete-filled steel tubular (CFST) column; Composite behavior; Blind-bolts; Joints; Shear loading; ANCHORED BLIND BOLTS; END-PLATE CONNECTION; CYCLIC BEHAVIOR; T-STUB; TENSILE BEHAVIOR; SECTION COLUMN; STEEL-TUBE; BEAM; STRENGTH;
D O I
10.1061/JSENDH.STENG-12813
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The performance of concrete-filled steel tubular (CFST) column joints with a group of extended hollo-bolts has been experimentally investigated under the influence of shear loading. The primary focus was to understand the performance of extended hollo-bolts in enhancing the transfer of shear load to the concrete core of the column by bolt bearing. The joint assembly was fabricated with a rigid end-plate, thereby overcoming the influence of endplates in the joint global behavior. A series of full-scale group hollo-bolted CFST column joint tests was carried out, where eight specimens were fabricated with a group of two hollo-bolts, arranged in one row and two rows in the assembly; another five specimens were fabricated with a group of four hollo-bolts, arranged in two rows. Apart from bolt arrangement, the other parameters studied included the use of standard and extended hollo-bolts, the embedment length of the hollo-bolt, and the bolt pitch distance. From the investigation, it is observed that all the joints failed in pure shear signifying utilization of the full capacity of the hollo-bolt, and no prominent bearing failure of concrete was observed. Enhanced composite behavior was achieved using the extended hollo-bolts as the shear load was transferred to the concrete core effectively. A group of two extended hollo-bolts in a single row transmits equal forces to the concrete core, whereas, when two or four extended hollo-bolts are in two rows, the upper row transmits more forces as compared to the bolts in the lower row. Lastly, with pitch distance of 2.5 times bolt hole diameter and beyond, the total strength of the joint is equal to the sum of strength of individual bolts, which confirms that the group action did not deteriorate the joint capacity. Subsequently, an analytical model for the global force-displacement behavior and joint shear strength is proposed by calibrating the test data obtained through this study.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Fire resistance of steel beam to square CFST column composite joints using RC slabs: Experiments and numerical studies
    Yang, You-Fu
    Fu, Feng
    FIRE SAFETY JOURNAL, 2019, 104 : 90 - 108
  • [32] Cyclic performance of fully assembled joints between H-Beam and CFST shear wall
    Liu, Yifeng
    Cai, Honghao
    Liu, Xiaoguang
    Zhao, Junxian
    Zhang, Chuntao
    STRUCTURES, 2023, 51 : 1655 - 1669
  • [33] BOLTED JOINTS IN STRUCTURAL STEELWORK: COMBINED IN-PLANE SHEAR AND MOMENT FOR HSFG BOLTS.
    Gurtuna, A.G.
    Burdekin, F.M.
    Metal construction, 1988, 20 (03): : 140 - 145
  • [34] Shear performance and failure mechanism of socket CFST column-beam connection with UHPC grouting
    Su, Sibo
    Zhang, Guangda
    Yu, Jiexin
    Han, Qiang
    Zhou, Daxing
    Du, Xiuli
    ENGINEERING STRUCTURES, 2024, 313
  • [35] Performance of bolted steel-beam to CFST-column joints using stiffened angles in column-removal scenario
    Gao, Shan
    Xu, Man
    Fu, Feng
    Guo, Lanhui
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 159 : 459 - 475
  • [36] EXPERIMENTAL STUDY ON THE EFFECT OF STRUCTURAL SIZE ON THE SEISMIC PERFORMANCE OF SQUARE CFST SHORT COLUMNS
    Jin L.
    Liang J.
    Li D.
    Du X.-L.
    Gongcheng Lixue/Engineering Mechanics, 2023, 40 (04): : 35 - 45
  • [37] Evolution of concrete encased - CFST column: A comprehensive review on structural behavior and performance characteristics
    Raveendran, Namitha
    Vasugi, K.
    STEEL AND COMPOSITE STRUCTURES, 2024, 51 (06): : 619 - 645
  • [38] Experimental investigation on shear behavior of steel beam-to-CFST column connections with irregular panel zone
    Mou, Ben
    Bai, Yongtao
    ENGINEERING STRUCTURES, 2018, 168 : 487 - 504
  • [39] Experimental study of flush end plate beam-to-CFST column composite joints with deconstructable bolted shear connectors
    Ataei, Abdolreza
    Bradford, Mark A.
    Valipour, Hamid R.
    ENGINEERING STRUCTURES, 2015, 99 : 616 - 630
  • [40] Seismic performance of concrete-encased CFST column to steel beam joints with different connection details
    Li, Wei
    Xu, Li-Feng
    Qian, Wei-Wu
    ENGINEERING STRUCTURES, 2020, 204