Structural Investigation of Shear Performance of Square CFST Column Joints with Extended Hollo-Bolts

被引:1
|
作者
Debnath, Partha Pratim [1 ]
Chan, Tak-Ming [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hung Hom, Kowloon, Hong Kong, Peoples R China
关键词
Concrete-filled steel tubular (CFST) column; Composite behavior; Blind-bolts; Joints; Shear loading; ANCHORED BLIND BOLTS; END-PLATE CONNECTION; CYCLIC BEHAVIOR; T-STUB; TENSILE BEHAVIOR; SECTION COLUMN; STEEL-TUBE; BEAM; STRENGTH;
D O I
10.1061/JSENDH.STENG-12813
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The performance of concrete-filled steel tubular (CFST) column joints with a group of extended hollo-bolts has been experimentally investigated under the influence of shear loading. The primary focus was to understand the performance of extended hollo-bolts in enhancing the transfer of shear load to the concrete core of the column by bolt bearing. The joint assembly was fabricated with a rigid end-plate, thereby overcoming the influence of endplates in the joint global behavior. A series of full-scale group hollo-bolted CFST column joint tests was carried out, where eight specimens were fabricated with a group of two hollo-bolts, arranged in one row and two rows in the assembly; another five specimens were fabricated with a group of four hollo-bolts, arranged in two rows. Apart from bolt arrangement, the other parameters studied included the use of standard and extended hollo-bolts, the embedment length of the hollo-bolt, and the bolt pitch distance. From the investigation, it is observed that all the joints failed in pure shear signifying utilization of the full capacity of the hollo-bolt, and no prominent bearing failure of concrete was observed. Enhanced composite behavior was achieved using the extended hollo-bolts as the shear load was transferred to the concrete core effectively. A group of two extended hollo-bolts in a single row transmits equal forces to the concrete core, whereas, when two or four extended hollo-bolts are in two rows, the upper row transmits more forces as compared to the bolts in the lower row. Lastly, with pitch distance of 2.5 times bolt hole diameter and beyond, the total strength of the joint is equal to the sum of strength of individual bolts, which confirms that the group action did not deteriorate the joint capacity. Subsequently, an analytical model for the global force-displacement behavior and joint shear strength is proposed by calibrating the test data obtained through this study.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Progressive collapse behaviour of extended endplate connection to square hollow column via blind Hollo-Bolts
    Wang, Wei
    Li, Ling
    Chen, Dabiao
    Xu, Ting
    THIN-WALLED STRUCTURES, 2018, 131 : 681 - 694
  • [2] Behaviour of I beam-SHS column steel joints with hollo-bolts: An experimental study
    Mesquita, A. C. B.
    Simoes da Silva, L. A. P.
    Jordao, S.
    TUBULAR STRUCTURES XIII, 2010, : 17 - +
  • [3] Performance of circular CFST column to steel beam joints with blind bolts
    Wang, Jingfeng
    Zhang, Na
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 130 : 36 - 52
  • [4] Studies on CFST column to steel beam joints using endplates and long bolts under central column removal
    Gao, Shan
    Yang, Bo
    Guo, Lanhui
    Xu, Man
    Fu, Feng
    STEEL AND COMPOSITE STRUCTURES, 2022, 42 (02): : 161 - 172
  • [5] Numerical investigation of demountable CFST K-joints using blind bolts
    Jin, Dengyiding
    Hou, Chao
    Shen, Luming
    Han, Lin-Hai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 160 : 428 - 443
  • [6] Research on performance of CFST column to steel beam joint with through bolts-extended endplate against progressive collapse
    Zheng L.
    Wang W.
    Li H.
    Li T.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (11): : 140 - 149
  • [7] Temperature analysis of extended end plate joints to square CFST columns in fire
    Wang, Jing-feng
    Wang, Hai-Tao
    Shi, Wei-Wei
    Sheng, Hong-Yu
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2016, 7 (04) : 306 - 315
  • [8] Seismic performance of reinforcement-lapped square CFST column base
    Yu, Yingying
    Yang, Yuanlong
    Guo, Lanhui
    Jiang, Shiyong
    Wang, Guojun
    Chen, Yohchia Frank
    THIN-WALLED STRUCTURES, 2025, 209
  • [9] Seismic performance of mixed column composed of square CFST column and circular RC column in Chinese archaized buildings
    Xue, Jianyang
    Zhou, Chaofeng
    Lin, Jianpeng
    STEEL AND COMPOSITE STRUCTURES, 2018, 29 (04): : 451 - 464
  • [10] Performance of new CFST square column-to-foundation connections for cyclic loads
    Abbas, Husain
    Siddiqui, Nadeem A.
    Khateeb, Baha M.
    Almusallam, Tarek H.
    Al-Salloum, Yousef A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 185