The behavior of concrete filled steel tubular columns infilled with high-strength geopolymer recycled aggregate concrete

被引:4
|
作者
Al-Rousan, Rajai Z. [1 ]
Sawalha, Haneen M. [1 ]
机构
[1] Jordan Univ Sci & Technol, Fac Engn, Dept Civil Engn, POB 3030, Irbid 22110, Jordan
来源
STEEL AND COMPOSITE STRUCTURES | 2024年 / 51卷 / 06期
关键词
CFST column; geopolymer concrete; high-strength; NLFEA; recycled aggregate; STUB COLUMNS; COMPRESSIVE BEHAVIOR; CIRCULAR CFST; PERFORMANCE; SQUARE; TUBES; SECTIONS;
D O I
10.12989/scs.2024.51.6.661
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The utilization of geopolymer recycled aggregate concrete (GRAC) as the infilled core of the concrete-filled steel tubular (CFST) columns provides superior economic and environmental benefits. However, limited research exists within the field of geopolymer recycled aggregate concrete considered a green and sustainable material, in addition to the limitation of the design guidelines to predict the behavior of such an innovative new material combination. Moreover, the behavior of high-strength concrete is different from the normal-strength one, especially when there is another material of high-strength properties, such as the steel tube. This paper aims to investigate the behavior of the axially loaded square high-strength GRACFST columns through the nonlinear finite element analysis (NLFEA). A total of thirty-two specimens were simulated using ABAQUS/Standard software with three main variables: recycled aggregate replacement ratio (0, 30, and 50) %, width-to-thickness ratios (52.0, 32.0, 23.4, and 18.7), and length-to-width ratio (3, 5, 9, and 12). During the analysis, the response in terms of the axial load versus the longitudinal strain was recorded and plotted. In addition, various mechanical properties were calculated and analyzed. In view of the results, it has been demonstrated that the mechanical properties of high-strength GRACFST columns such as ultimate load-bearing capacity, compressive stiffness, energy absorption capacity, and ductility increase with the increase of the steel tube thickness owing to the improvement of the confinement effect of the steel tube. In contrast, the incorporation of the recycled aggregate adversely affected the mentioned properties except the ductility, while the increase of the recycled aggregate replacement ratio improved the column's ductility. Moreover, it has been found that the increase in the length-to-width ratio significantly reduced both the failure strain and the energy absorption capacity. Finally, the obtained NLFEA results of the ultimate load-bearing capacity were compared with the corresponding predicted capacities by numerous codes. It has been concluded that AISC, ACI, and EC give conservative predictions for the ultimate load-bearing capacity since the confinement effect was not considered by these codes.
引用
收藏
页码:661 / 678
页数:18
相关论文
共 50 条
  • [41] Fire behaviour of axially loaded high-strength concrete-filled circular high-strength steel tubular columns
    Du, Tao
    Liu, Faqi
    Yang, Hua
    Peng, Kang
    ENGINEERING STRUCTURES, 2025, 328
  • [42] Behaviours of circular high-strength concrete-filled high-strength steel tubular columns after constant heating
    Du, Tao
    Liu, Faqi
    Wei, Huiyu
    Li, Ying
    Yang, Hua
    Peng, Kang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 221
  • [43] Cyclic behavior of full-scale reinforced high-strength recycled aggregate concrete columns
    Li, Yanna
    Dong, Hongying
    Cao, Wanlin
    Zhang, Jianwei
    Guo, Yanli
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2023, 32 (03):
  • [44] Prediction model on compressive strength of recycled aggregate concrete filled steel tube columns
    Nour, Abdikarim Idiris
    Guneyisi, Esra Mete
    COMPOSITES PART B-ENGINEERING, 2019, 173
  • [45] Behaviour of eccentrically loaded high-strength rectangular concrete-filled steel tubular columns
    Liu, Dalin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (08) : 839 - 846
  • [46] Axial compressive behaviour of corroded concrete-filled high-strength steel tubular columns
    Xiong, Qingqing
    Wang, Xinhua
    Du, Yansheng
    Zhang, Wang
    Li, Ranran
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 228
  • [47] High strength concrete-filled tubular steel columns in fire
    Bahr, O.
    TUBULAR STRUCTURES XII, 2009, : 461 - 467
  • [48] Mechanical Properties of High Strength Concrete Filled Steel Tubular Columns
    Tan Kefeng
    Liu Laibao
    ADVANCED MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 472-475 : 1119 - 1125
  • [49] Bond strength of deformed steel bars in high-strength recycled aggregate concrete
    Prince, M. John Robert
    Singh, Bhupinder
    MATERIALS AND STRUCTURES, 2015, 48 (12) : 3913 - 3928
  • [50] Bond strength of deformed steel bars in high-strength recycled aggregate concrete
    M. John Robert Prince
    Bhupinder Singh
    Materials and Structures, 2015, 48 : 3913 - 3928