Dissolved gas analysis based fuzzy logic feamework for power transformer asset management

被引:0
|
作者
Aliyev, Tural [1 ]
Ibrahimov, Jalal [1 ]
Qracova, Shahla [1 ]
Isgandarova, Zarifa [1 ]
机构
[1] Azerbaijan State Oil & Ind Univ, Baku, Azerbaijan
来源
PRZEGLAD ELEKTROTECHNICZNY | 2024年 / 100卷 / 08期
关键词
Dissolved Gas Analysis; transformer oil; Fuzzy Logic Approach; Asset Management Decision;
D O I
10.15199/48.2024.08.38
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
. Dissolved Gas Analysis (DGA) is a vital tool for monitoring power transformer conditions. Despite its effectiveness, current interpretation techniques lack consistency and often rely on personnel experience, leading to varied conclusions for the same oil sample. This paper proposes a fuzzy logic approach to standardize DGA interpretation, aiming to establish a uniform method for critical transformer ranking and informed asset management decisions. The approach integrates existing DGA interpretation techniques into an expert model, enhancing reliability. The model, developed from 338 oil samples, offers a consistent and accurate basis for transformer condition assessment and asset management.
引用
收藏
页码:185 / 188
页数:4
相关论文
共 50 条
  • [21] Fuzzy Logic Approach for Transformer Remnant Life Prediction and Asset Management Decision
    Abu Bakar, Norazhar
    Abu-Siada, A.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (05) : 3199 - 3208
  • [22] Power transformer asset management
    Arshad, M
    Islam, SM
    Khaliq, A
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 1395 - 1398
  • [23] Dissolved Gas Analysis of Transformers Based on Rough Set and Fuzzy Logic Methods
    Kadim, E. J.
    Hee, C. F.
    Azis, N.
    Jasni, J.
    Ahmad, S. A.
    Ab Kadir, M. Z. A.
    2015 IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2015, : 268 - 271
  • [24] Fuzzy logic based relay for power transformer protection
    Saha, Murari M.
    Hillstrom, Birger
    Kasztenny, Bogdan
    Rosolowski, Eugeniusz
    ABB Review, 1998, (01): : 41 - 48
  • [25] Diagnosis and prognosis of incipient faults and insulation status for asset management of power transformer using fuzzy logic controller & fuzzy clustering means
    Soni, Rahul
    Mehta, Bhinal
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 220
  • [26] Dissolved gas analysis based on GA and FCM for power transformer fault diagnosis
    Nanjing University of Aeronautics and Astronautics, Nanjing 210006, China
    不详
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2008, 28 (02): : 15 - 18
  • [27] Feature Selection in Power Transformer Fault Diagnosis based on Dissolved Gas Analysis
    Samirmi, Farhad Davoodi
    Tang, Wenhu
    Wu, Henry
    2013 4TH IEEE/PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT EUROPE), 2013,
  • [28] Dissolved gas analysis of transformers using fuzzy logic approach
    Aghaei, J.
    Gholami, A.
    Shayanfar, H. A.
    Dezhamkhooy, A.
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2010, 20 (05): : 630 - 638
  • [29] Aspects of Power Transformer Asset Management
    Elkinson, K.
    Topjian, G.
    Lawrence, M.
    McGrail, A. J.
    2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,
  • [30] Impact of Load Ramping on Power Transformer Dissolved Gas Analysis
    Cui, Huize
    Yang, Liuqing
    Li, Shengtao
    Qu, Guanghao
    Wang, Hao
    Abu-Siada, Ahmed
    Islam, Syed
    IEEE ACCESS, 2019, 7 : 170343 - 170351