Investigation on Pollution-Induced Flashovers of In-Service Insulators in Ethiopian Power Transmission Lines

被引:1
|
作者
Desta, Berhanu Zelalem [1 ,2 ]
Wogari, Mengesha M. [2 ]
Gubanski, Stanislaw M. [3 ]
机构
[1] Bahir Dar Univ, Fac Elect & Comp Engn, Bahir Dar Inst Technol, POB 26, Bahir Dar, Ethiopia
[2] Addis Ababa Univ, Addis Ababa Inst Technol, Sch Elect & Comp Engn, POB 385, Addis Ababa, Ethiopia
[3] Chalmers Univ Technol, Dept Elect Engn, S-41296 Gothenburg, Sweden
关键词
Ethiopian power transmission system; unexplained outages; pollution flashover; outdoor insulators; silicone rubber polymeric insulators; site pollution severity; FAULTS;
D O I
10.3390/en17092007
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Power transmission lines in Ethiopia are experiencing an alarmingly high frequency of unexplained outages triggered by environmental factors, which significantly undermine the reliability of the country's power system. This paper presents investigations aiming to identify those among the unexplained fault records that have been caused by pollution induced flashovers. An identification method is developed, which associates the contextual fault features, such as information about the characteristics of the fault, fault location, and time of day, as well as month of its occurrence with local meteorological/climatic and environmental conditions. A total number of 4231 unexplained faults, recorded between 2015 and 2022, were analyzed. Among them, 1045 faults (24.7%) were identified as being most likely caused by pollution induced flashovers. The entire network suffered from more than 130 pollution-induced flashovers annually with a frequency of about 0.8 faults/100 km/year. The fault frequency strongly differed among the grid regions, being highest in the Northeast and lowest in the Southwest region. Moreover, the performed analyses also concentrated on the evaluation of the pollution performance of various insulator types employed in the network. The results indicate that porcelain insulators have the highest pollution-induced flashover intensity of 1.47 faults/year/1000 units, followed by silicone rubber polymeric composite insulators and glass insulators with the respective intensities of 1.21 and 0.83 faults/year/1000 units. These results indicate that despite the high expectations towards the pollution performance of silicone rubber polymeric insulators, their use in the Ethiopian climatic and environmental conditions appears to be unsatisfactory.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Automatic Surveillance and Analysis of Snow and Ice Coverage on Electrical Insulators of Power Transmission Lines
    Gu, Irene Y. H.
    Sistiaga, Unai
    Berlijn, Sonja M.
    Fahlstrom, Anders
    COMPUTER VISION AND GRAPHICS, 2009, 5337 : 368 - +
  • [22] Using Satellite Imagery to Improve Local Pollution Models for High-Voltage Transmission Lines and Insulators
    Krammer, Peter
    Kvassay, Marcel
    Mojzis, Jan
    Kenyeres, Martin
    Ockay, Milos
    Hluchy, Ladislav
    Pavlov, Lubos
    Skurcak, Lubos
    FUTURE INTERNET, 2022, 14 (04):
  • [23] Investigation and analysis on electromagnetic impact of UHVDC power transmission lines on telecommunication lines
    Chi, X. (chixinghe@sdepci.com), 1600, Power System Technology Press (38):
  • [24] An investigation into series power tapping options of HVDC transmission lines
    Hartshorne, Andre
    Mouton, Hendrik du Toit
    Madawala, Udaya K.
    2013 1ST INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE (IFEEC 2013), 2013, : 568 - 573
  • [25] Silicone insulators of power transmission lines with a variable inorganic load concentration: Electrical and physiochemical analyses
    Cardoso, Rodolfo
    Balestro, Ana Claudia
    Dellallibera, Adriano
    Costa, Eduardo Coelho M.
    Angelini, Joceli Maria G.
    Innocentini Mei, Lucia Helena
    MEASUREMENT, 2014, 50 : 63 - 73
  • [26] Dynamic Simulation of Power Systems Considering Transmission Lines Icing and Insulators Flashover in Extreme Weather
    Chen, Lizheng
    Shi, Xiaohan
    Peng, Bo
    Sun, Jingwen
    IEEE ACCESS, 2022, 10 : 39656 - 39664
  • [27] Intelligent Video Surveillance for Detecting Snow and Ice Coverage on Electrical Insulators of Power Transmission Lines
    Gu, Irene Y. H.
    Sistiaga, Unai
    Berlijn, Sonja M.
    Fahlstrom, Anders
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, PROCEEDINGS, 2009, 5702 : 1179 - +
  • [28] Research on Electric Field Strength Distortion near the Insulators When there is Any Guano-caused Flashover of Insulators of Power Transmission Lines
    Zheng Jingwen
    Li Yuchao
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [29] Investigation on Natural Contamination Deposition of Insulators on ±500kV DC Transmission Lines in Different Environments
    Liu, Qin
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 347 - 349
  • [30] A SPICE simulation of lightning induced overvoltages on power transmission lines
    Andreotti, A
    De Martinis, U
    Verolino, L
    ADVANCES IN ENGINEERING SOFTWARE, 2000, 31 (10) : 757 - 762