Investigation on Pollution-Induced Flashovers of In-Service Insulators in Ethiopian Power Transmission Lines

被引:1
|
作者
Desta, Berhanu Zelalem [1 ,2 ]
Wogari, Mengesha M. [2 ]
Gubanski, Stanislaw M. [3 ]
机构
[1] Bahir Dar Univ, Fac Elect & Comp Engn, Bahir Dar Inst Technol, POB 26, Bahir Dar, Ethiopia
[2] Addis Ababa Univ, Addis Ababa Inst Technol, Sch Elect & Comp Engn, POB 385, Addis Ababa, Ethiopia
[3] Chalmers Univ Technol, Dept Elect Engn, S-41296 Gothenburg, Sweden
关键词
Ethiopian power transmission system; unexplained outages; pollution flashover; outdoor insulators; silicone rubber polymeric insulators; site pollution severity; FAULTS;
D O I
10.3390/en17092007
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Power transmission lines in Ethiopia are experiencing an alarmingly high frequency of unexplained outages triggered by environmental factors, which significantly undermine the reliability of the country's power system. This paper presents investigations aiming to identify those among the unexplained fault records that have been caused by pollution induced flashovers. An identification method is developed, which associates the contextual fault features, such as information about the characteristics of the fault, fault location, and time of day, as well as month of its occurrence with local meteorological/climatic and environmental conditions. A total number of 4231 unexplained faults, recorded between 2015 and 2022, were analyzed. Among them, 1045 faults (24.7%) were identified as being most likely caused by pollution induced flashovers. The entire network suffered from more than 130 pollution-induced flashovers annually with a frequency of about 0.8 faults/100 km/year. The fault frequency strongly differed among the grid regions, being highest in the Northeast and lowest in the Southwest region. Moreover, the performed analyses also concentrated on the evaluation of the pollution performance of various insulator types employed in the network. The results indicate that porcelain insulators have the highest pollution-induced flashover intensity of 1.47 faults/year/1000 units, followed by silicone rubber polymeric composite insulators and glass insulators with the respective intensities of 1.21 and 0.83 faults/year/1000 units. These results indicate that despite the high expectations towards the pollution performance of silicone rubber polymeric insulators, their use in the Ethiopian climatic and environmental conditions appears to be unsatisfactory.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Assessing insulators vulnerability to pollution-induced flashover for power system resilience studies
    Ciapessoni, E.
    Cirio, D.
    Pitto, A.
    Pirovano, G.
    2021 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2021,
  • [2] Fire induced flashovers of transmission lines: Theoretical models
    Sukhnandan, A
    Hoch, DA
    2002 IEEE AFRICON, VOLS 1 AND 2: ELECTROTECHNOLOGICAL SERVICES FOR AFRICA, 2002, : 617 - 622
  • [3] FIRE INDUCED FLASHOVERS OF EHV TRANSMISSION-LINES
    WEST, HJ
    MCMULLAN, DW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (04): : 1142 - 1142
  • [4] Natural Pollution Accumulation Characteristics of Composite Insulators for Overhead Transmission Lines in Hunan Power Grid
    Chao Y.
    Gao J.
    Yue Y.
    Wang F.
    Wang C.
    Huang F.
    Chao, Yafeng (yfchao5335@163.com), 2018, Science Press (44): : 2799 - 2806
  • [5] Environmental Pollution Effects on Insulators of Northern Egypt HV Transmission Lines
    Abouelsaad, M. A.
    Abouelatta, M. A.
    Arafa, B.
    Ibrahim, M. E.
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 35 - 38
  • [6] Inspection of Insulators on High-Voltage Power Transmission Lines
    Han, Sunsin
    Hao, Ru
    Lee, Jangmyung
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (04) : 2319 - 2327
  • [7] Vision Diagnostics of Power Transmission Lines: Approach to Recognition of Insulators
    Wronkowicz, Angelika
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON COMPUTER RECOGNITION SYSTEMS, CORES 2015, 2016, 403 : 431 - 440
  • [8] In-service aging and degradation of 345 kV EPDM transmission line insulators in a coastal environment
    Sundararajan, R
    Mohammed, A
    Chaipanit, N
    Karcher, T
    Liu, ZQ
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2004, 11 (02) : 348 - 361
  • [9] In-Service Aged Composite Insulators at Transmission Line Investigated by the Micro-Computerized Tomography
    Silva, Pietro P. J. C.
    Shinohara, Armando H.
    Pacheco, Admilson P.
    Castro Filho, Zurdival P.
    Monteiro, Sergio L. P.
    MATERIALS TRANSACTIONS, 2012, 53 (04) : 617 - 620
  • [10] In-service aged composite insulators at transmission line investigated by the micro-computerized tomography
    UFPE - Federal University of Pernambuco, Department of Mechanical Engineering, Recife-PE, 50740-530, Brazil
    不详
    Mater. Trans., 4 (617-620):