Flexible Dual-Channel Molecularly Imprinted Electrochemical Sensor for Simultaneously Monitoring Sweat Cortisol and Lactate Levels

被引:2
|
作者
Pei, Siying [1 ]
Ji, Wenhui [2 ]
Yang, Ya [1 ]
Liu, Tianwei [1 ]
Yang, Shuo [1 ]
Wu, Jiayi [1 ]
Dai, Jiangxuan [2 ]
Hou, Xiyan [3 ]
Wu, Qiong [1 ]
Li, Lin [2 ]
机构
[1] Nanjing Tech Univ NanjingTech, Inst Adv Mat IAM, Key Lab Flexible Elect KLOFE, Nanjing 211800, Jiangsu, Peoples R China
[2] Xiamen Univ, Inst Flexible Elect IFE, Future Technol, Xiamen 361005, Fujian, Peoples R China
[3] Dalian Minzu Univ DLMU, Coll Life Sci, Key Lab Biotechnol & Bioresources Utilizat, Minist Educ, Dalian 116600, Liaoning, Peoples R China
来源
ANALYSIS & SENSING | 2024年 / 4卷 / 05期
基金
中国国家自然科学基金;
关键词
Cortisol; flexible sensor; lactate; molecularly imprinted polymer; sweat monitoring; LACTIC-ACID; POLYMER; RECOGNITION; BIOSENSOR; RESPONSES; ELECTRODE; EXERCISE; HYPOXIA; OXIDASE; PROTEIN;
D O I
10.1002/anse.202400003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
While exercise offers significant potential to enhance overall well-being, unscientific exercise practices often cause exercise fatigue, posing a threat to human health. Flexible sweat sensors have garnered considerable attention owing to their ability to continuously, non-invasively, and dynamically monitor human health during exercise at the molecular level. Therefore, in this study, we constructed a flexible molecularly imprinted polymer (MIP) sensor for the real-time monitoring of cortisol and lactate levels in sweat using cortisol or lactate as template molecules and pyrrole (Py) as functional monomer. Prussian blue (PB) was embedded into the MIP as a built-in redox probe, eliminating the need for an additional probe and facilitating the simultaneous quantification of cortisol and lactate concentrations. Moreover, the MIP-doped platinum nanoparticles (PtNPs) ehanced the electron transfer capability, further improving the sensitivity of the sensors. The fabricated flexibile cortisol and lactate MIP sensors demonstrated low limits of detection (LOD; 1.07 nM and 1.09 mM, respectively), high sensitivity (0.09 mu A lg[nM]-1 and 1.28 mu A lg[nM]-1), and exceptional stability and selectivity. The flexible MIP sensors could continuously and dynamically monitor changes in sweat cortisol and lactate concentrations, thus contributing to the advancement of next-generation flexible sweat electrochemical sensors and providing a crucial tool for monitoring exercise fatigue. Flexible cortisol and lactate MIP sensors were prepared by in situ electrodeposition K2PtCl6 and co-electropolymerizing K2PtCl6, PB, Py, and functional monomer cortisol/lactate. It was connected to a circuit board and secured to a cap, enabling the direct measurement of human sweat cortisol and lactate levels during exercise to monitor exercise fatigue. image
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A molecularly imprinted electrochemical sensor with dual functional monomers for selective determination of gatifloxacin
    Yan Huang
    Xuyuan Sun
    Jing Yang
    Zhiyuan Cao
    Rujie Wang
    Li Li
    Yaping Ding
    Microchimica Acta, 2023, 190
  • [22] A Flexible and Integrated Electrochemical Sensor for Monitoring pH and Uric Acid in Sweat
    Zhou, Liang
    Cui, Yuan
    He, Chun-Xiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (04) : 516 - 522
  • [23] Self-powered molecular imprinted polymers-based triboelectric sensor for noninvasive monitoring lactate levels in human sweat
    Kanokpaka, Pawisa
    Chang, Ling-Yu
    Wang, Bung-Chen
    Huang, Tsung-Han
    Shih, Mu-Jie
    Hung, Wei-Song
    Lai, Juin-Yih
    Ho, Kuo-Chuan
    Yeh, Min-Hsin
    NANO ENERGY, 2022, 100
  • [24] Nano gold-doped molecularly imprinted electrochemical sensor for rapid and ultrasensitive cortisol detection
    Yeasmin, Sanjida
    Wu, Bo
    Liu, Ye
    Ullah, Ahasan
    Cheng, Li-Jing
    BIOSENSORS & BIOELECTRONICS, 2022, 206
  • [25] NFC-Enabled Dual-Channel Flexible Printed Sensor Tag
    Choi, Jonghyun
    Visagie, Ian
    Chen, Yi
    Abbel, Robert
    Parker, Kate
    SENSORS, 2023, 23 (15)
  • [26] A dual-functional polyaniline film-based flexible electrochemical sensor for the detection of pH and lactate in sweat of the human body
    Zhu, Chonghui
    Xue, Hua
    Zhao, Hongran
    Fei, Teng
    Liu, Sen
    Chen, Qidai
    Gao, Bingrong
    Zhang, Tong
    TALANTA, 2022, 242
  • [27] A Wearable Electrochemical Sensor Based on a Molecularly Imprinted Polymer Integrated with a Copper Benzene-1,3,5-Tricarboxylate Metal-Organic Framework for the On-Body Monitoring of Cortisol in Sweat
    Tang, Pingping
    He, Feiyu
    POLYMERS, 2024, 16 (16)
  • [28] Dual-Channel Linear Optical Sampling for Simultaneously Monitoring Ultrafast Intensity and Phase Modulation
    Okamoto, Keiji
    Ito, Fumihiko
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2009, 27 (12) : 2169 - 2175
  • [29] Fabrication of electrochemical sensor based on molecularly imprinted polymers for monitoring chlorpyrifos in real samples
    Singh, Damnita
    Verma, Neelam
    Bhari, Ranjeeta
    Kumar, Kuldeep
    BULLETIN OF MATERIALS SCIENCE, 2024, 47 (02)
  • [30] Flexible Electrochemical Sensor Based on NiCu(OOH) for Monitoring Urea in Human Sweat
    Yoon, Jaesik
    Sim, Myeongseok
    Oh, Tae-Sik
    Yoon, Young Soo
    Kim, Dong-Joo
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (11)