Effect of horizontal radiant temperature asymmetry on thermal comfort and environmental parameters in a warm sitting area

被引:0
|
作者
苏智群
夏绍毅
机构
[1] DeptofMechanicalEngineering,Yung-TaInstituteofTechnologyandCommerce
关键词
D O I
暂无
中图分类号
TU111 [建筑热工学];
学科分类号
摘要
Taiwan is a hot and humid place;in addition,the sunlight is strong and sufficient,the naturally ventilated classrooms have large-area windows for better lighting and ventilation in Taiwan.However,subjects sitting close to the large-area windows will encounter the problem of radiant temperature asymmetry,which may cause local thermal discomfort during summer.Hence,this paper is to investigate the influence of horizontal radiant temperature asymmetry on the thermal sensation of subjects and the correlative variation of environmental parameters in a warm sitting area.The evaluation results show that the predicted mean vote(PMV)index can be used to predict the overall thermal sensation of a group of sedentary subjects in a warm environment with horizontal radiant temperature asymmetry;even subjects feel local discomfort on exposed parts of their body.The measured results of environmental parameters indicate that the averaged radiant temperature difference is about 4.6 ℃ from right shoulder to left shoulder;the temperature difference does not only cause correlative variations of other environmental parameters,but also result in thermal discomfort on the right cheeks and forearms of subjects in the warm sitting area.
引用
收藏
页码:847 / 852
页数:6
相关论文
共 50 条
  • [21] Analysis on the impact of mean radiant temperature for the thermal comfort of underfloor air distribution systems
    Chung, Jae Dong
    Hong, Hiki
    Yoo, Hoseon
    ENERGY AND BUILDINGS, 2010, 42 (12) : 2353 - 2359
  • [22] Comparison of different methods of estimating the mean radiant temperature in outdoor thermal comfort studies
    Krueger, E. L.
    Minella, F. O.
    Matzarakis, A.
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2014, 58 (08) : 1727 - 1737
  • [23] Comparison of different methods of estimating the mean radiant temperature in outdoor thermal comfort studies
    E. L. Krüger
    F. O. Minella
    A. Matzarakis
    International Journal of Biometeorology, 2014, 58 : 1727 - 1737
  • [24] Thermal comfort temperature range for factory workers in warm humid tropical climates
    Wijewardane, S.
    Jayasinghe, M. T. R.
    RENEWABLE ENERGY, 2008, 33 (09) : 2057 - 2063
  • [25] The effect of indoor wall temperature on thermal comfort
    Fu, JP
    Ning, ZY
    Zou, XY
    Tao, Y
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 249 - 251
  • [26] Local thermal environment and thermal comfort of a novel low-temperature radiant structure using CFD simulation
    Liang, Yuying
    Wu, Huijun
    Yang, Jianming
    Huang, Gongsheng
    Energy and Buildings, 2024, 308
  • [27] Parametric study on the effect of radiant heating system on indoor thermal comfort with/without external thermal disturbance
    Xie, Xing
    Xia, Fei
    Zhao, Yu-qian
    Xu, Bin
    Wang, Yang-liang
    Pei, Gang
    ENERGY, 2022, 249
  • [28] On the effects of the mean radiant temperature evaluation in the assessment of thermal comfort by dynamic energy simulation tools
    Alfano, Francesca Romana d'Ambrosio
    Pepe, Daniela
    Riccio, Giuseppe
    Vio, Michele
    Palella, Boris Igor
    BUILDING AND ENVIRONMENT, 2023, 236
  • [29] Effect of a radiant thermal comfort system on growth and state of the respiratory function of piglet blood
    S. V. Kabatov
    N. E. Usova
    Russian Agricultural Sciences, 2007, 33 (6) : 397 - 399
  • [30] An experimental investigation on the effect of lighting colour of localized radiant panel thermal comfort system
    Picco, Marco
    Bernagozzi, Marco
    BUILDING AND ENVIRONMENT, 2024, 258