Effect of contact thermal resistance on temperature distributions of concrete-filled steel tubes in fire

被引:11
|
作者
吕学涛
杨华
张素梅
机构
[1] SchoolofCivilEngineering,HarbinInstituteofTechnology
关键词
D O I
暂无
中图分类号
TU398.9 [];
学科分类号
摘要
To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact thermal resistance was therefore proposed with the supporting of massive numbers of collected test data.Parametric analysis was conducted subsequently towards the cross-sectional temperature distribution of CFST columns in four-side fire,in which the exposure time,width of the cross section,steel ratio were taken into account with considering contact thermal resistance.It was found that contact thermal resistance has little effect on the overall temperature regulation with the exposure time,the width of cross-section or the change of steel ratio.However,great temperature dropping at the concrete adjacent to the contact interface,and gentle temperature increase at steel tube,exist if considering contact thermal resistance.The results of the study are expected to provide theoretical basis for the fire resistance behavior and design of the CFST columns being exposure to fire.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [11] Stability of rectangular concrete-filled steel tubes
    Kanishchev, Ruslan
    INTERNATIONAL SCIENCE CONFERENCE SPBWOSCE-2016 - SMART CITY, 2017, 106
  • [12] Axially loaded concrete-filled steel tubes
    Srinivasan, CN
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1999, 125 (10): : 1202 - 1206
  • [13] Bond behavior in concrete-filled steel tubes
    Tao, Zhong
    Song, Tian-Yi
    Uy, Brian
    Han, Lin-Hai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 120 : 81 - 93
  • [14] PERFORMANCE STUDY OF CONCRETE-FILLED STEEL TUBES
    Chair, A.
    Djebbar, A.
    Djebbar, N.
    INTERNATIONAL CONGRESS ON MATERIALS & STRUCTURAL STABILITY, 2014, 11
  • [15] Creep modeling for concrete-filled steel tubes
    Naguib, W
    Mirmiran, A
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (11) : 1327 - 1344
  • [16] Axially loaded concrete-filled steel tubes
    Schneider, SP
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (10): : 1125 - 1138
  • [17] Fire Resistance Design of Concrete-Filled Steel Tube Stub Columns
    Mohamed Ghannam
    Tian Yi Song
    Fire Technology, 2021, 57 : 911 - 942
  • [18] FIRE RESPONSES AND RESISTANCE OF CONCRETE-FILLED STEEL TUBULAR FRAME STRUCTURES
    Yu, Min
    Zha, Xiaoxiong
    Ye, Jianqiao
    Li, Yi
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2010, 10 (02) : 253 - 271
  • [19] Fire Resistance Design of Concrete-Filled Steel Tube Stub Columns
    Ghannam, Mohamed
    Song, Tian Yi
    FIRE TECHNOLOGY, 2021, 57 (02) : 911 - 942
  • [20] Fire resistance of concrete-filled steel plate composite (CFSPC) walls
    Wei, Feng
    Fang, Cheng
    Wu, Bo
    FIRE SAFETY JOURNAL, 2017, 88 : 26 - 39