Static progressive collapse test on precast concrete frames with dry connections

被引:0
|
作者
An Y. [1 ]
Li Y. [1 ]
Lu X. [2 ]
Ren P. [3 ]
机构
[1] Beijing Key Laboratory of Earthquake Engineering and Structural Retrofit, Beijing University of Technology, Beijing
[2] Key Laboratory of Civil Engineering Safety and Durability of Ministry of Education, Tsinghua University, Beijing
[3] China Institute of Building Standard Design & Research Co., Ltd, Beijing
来源
Jianzhu Jiegou Xuebao/Journal of Building Structures | 2020年 / 41卷 / 07期
关键词
Bolted connection; Collapse resistance; Precast concrete frame; Static progressive collapse test; Unbonded prestressed connection;
D O I
10.14006/j.jzjgxb.2018.0690
中图分类号
学科分类号
摘要
The mechanical behavior of beam-column joints under large deformation is the key factor affecting the progressive collapse resistance of precast concrete frame structures with dry-connections. In this paper, a static progressive collapse test was conducted on three beam-column substructure specimens, including one bolted connection specimen, one unbonded prestressed connection specimen and one cast-in-situ specimen. The failure modes of joints and the static collapse resistance of substructures under different deformations were analyzed via test results. The dynamic collapse resistance of substructures was also investigated based on the energy conservation principle. Compared with the cast-in-situ specimen, the static and dynamic collapse resistances of the bolted connection specimen under the compression arch mechanism are reduced by 41% and 45%, respectively, due to the buckling of connection steel plate which has been exposed to the tensile force at beam ends. These resistances under the catenary mechanism are also reduced by 27% and 37%, respectively, owing to the fracture of connection angle steel and bolts. For the unbonded prestressed connection specimen, the static and dynamic collapse resistances under the compression arch mechanism are reduced by 39% and 45%, respectively, comparing with the cast-in-situ specimen due to the early crush of concrete. Although the static collapse resistance under the catenary mechanism is increased by 52%, which is contributed by the prestressed steel bars, the corresponding dynamic collapse resistance of the unbonded prestressed connection specimen is 17% lower than that of the cast-in-situ specimen due to the smaller accumulated dissipating energy under the compression arch mechanism. © 2020, Editorial Office of Journal of Building Structures. All right reserved.
引用
收藏
页码:102 / 109
页数:7
相关论文
共 20 条
  • [11] Code for seismic design of building: GB 50011-2010, (2016)
  • [12] CAI Xiaoning, Study on seismic capacity and design method of prestressed precast concrete frame, (2012)
  • [13] LIN K Q, LU X Z, LI Y, Et al., Experimental study of a novel multi-hazard resistant prefabricated concrete frame structure, Soil Dynamics and Earthquake Engineering, (2018)
  • [14] Design of buildings to resist progressive collapse:unified facilities criteria (UFC) 4-023-03, (2016)
  • [15] CHU Mingjin, ZHOU Yulong, LU Xinzheng, Et al., An experimental study on one-way reinforced concrete beam-slab substructures for resisting progressive collapse, China Civil Engineering Journal, 49, 2, pp. 31-40, (2016)
  • [16] ZHOU Yulong, LI Yi, LU Xinzheng, Et al., An analytical model of compressive arch action of reinforced concrete frames to resist progressive collapse, Engineering Mechanics, 33, 4, pp. 34-42, (2016)
  • [17] LI Yi, YE Lieping, LU Xinzheng, Progressive collapse resistance demand of RC frame structures based on energy method I: beam mechanism, Journal of Building Structures, 32, 11, pp. 1-8, (2011)
  • [18] LI Yi, LU Xinzheng, YE Lieping, Progressive collapse resistance demand of RC frame structures based on energy method II: catenary mechanism, Journal of Building Structures, 32, 11, pp. 9-16, (2011)
  • [19] GUO Yiqing, YU Jun, Dynamic structural response of progressive collapse under a single-column-removal scenario, Engineering Mechanics, 34, 4, pp. 72-77, (2017)
  • [20] Code for anti-collapse design of building structures:CECS 392:2014, (2014)