Parametric analysis and comprehensive multi-criteria evaluation of double-stage organic Rankine cycle

被引:2
|
作者
Zhang, Shurong [1 ,2 ]
Sun, Yeshan [3 ]
机构
[1] Ludong Univ, Sch Energy & Power Engn, Yantai 264025, Shandong, Peoples R China
[2] Ludong Univ, Low Carbon Energy Inst, Yantai 264025, Shandong, Peoples R China
[3] Yantai Longyuan Power Technol Co Ltd, Yantai 264006, Shandong, Peoples R China
关键词
AHP-Entropy method; Multi-criteria evaluation; Comprehensive system performance; WASTE HEAT; ORC; OPTIMIZATION; PRESSURE; ENERGY; SINGLE;
D O I
10.1016/j.csite.2024.104245
中图分类号
O414.1 [热力学];
学科分类号
摘要
Double -stage organic Rankine cycle (DORC) is a more effective mechanism of circulation for recovering heat released from industrial wastewater. It is crucial to determine the optimum operating circumstances for the DORC system, and its effectiveness cannot be effectively assessed by applying a single objective evaluation approach. The AHP-entropy analysis method is utilized to establish a three -level assessment system, taking into account several indicators, in order to execute a thorough study of the DORC system. Eight organic fluids, including R113, R124, R1233zd(E), etc, are chosen as the working mediums of the DORC system. The results demonstrate that the heat source temperature exists maximum value that match the working fluids under the impact of the pinch point temperature difference and the critical temperature of the working medium. When the evaporation pressure increases, the whole system performance improves, according to the AHP-entropy analysis of the operating state that corresponds to the single goal optimum value. When the critical temperature of the working medium is approximately 50 degrees C above the hot water temperature for a given heat source, the system performs more effectively. Additionally, when the heat source temperature is close to the critical temperature of the eight organic fluids, the DORC system operates more effectively.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Performance Analysis and Comprehensive Evaluation of Solar Organic Rankine Cycle Combined with Transcritical CO2 Refrigeration Cycle
    Zhang, Na
    Xu, Po
    Wang, Yiming
    Tong, Wencai
    Yang, Zhao
    ENERGIES, 2023, 16 (14)
  • [32] Parametric analysis of a solar Organic Rankine Cycle trigeneration system for residential applications
    Cioccolanti, Luca
    Tascioni, Roberto
    Bocci, Enrico
    Villarini, Mauro
    ENERGY CONVERSION AND MANAGEMENT, 2018, 163 : 407 - 419
  • [33] Parametric exergetic and energetic analysis of a novel modified organic rankine cycle with ejector
    Tashtoush, Bourhan
    Algharbawi, Almutaz Ballah R.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 19
  • [34] Parametric optimization and range analysis of Organic Rankine Cycle for binary-cycle geothermal plant
    Wang, Xing
    Liu, Xiaomin
    Zhang, Chuhua
    ENERGY CONVERSION AND MANAGEMENT, 2014, 80 : 256 - 265
  • [35] Parametric theoretical study of a two-stage solar organic Rankine cycle for RO desalination
    Kosmadakis, G.
    Manolakos, D.
    Papadakis, G.
    RENEWABLE ENERGY, 2010, 35 (05) : 989 - 996
  • [36] Parametric Study on the Exergy Analysis of a Dual Evaporator Cooling Cycle Powered by the Organic Rankine Cycle
    Touaibi, Rabah
    Koten, Hasan
    MECHANIKA, 2023, 29 (03): : 200 - 206
  • [37] Performance evaluation of two-stage turbine for the organic rankine cycle system
    Lim, Hyung-Soo
    Choi, Bum-Seog
    Park, Moo-Ryong
    Hwang, Soon-Chan
    Park, Jun-Young
    Seo, Jeongmin
    Bang, Je-Sung
    Kim, Byung Ok
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2017, 31 (12) : 5849 - 5855
  • [38] Performance evaluation of two-stage turbine for the organic rankine cycle system
    Hyung-Soo Lim
    Bum-Seog Choi
    Moo-Ryong Park
    Soon-Chan Hwang
    Jun-Young Park
    Jeongmin Seo
    Je-Sung Bang
    Byung Ok Kim
    Journal of Mechanical Science and Technology, 2017, 31 : 5849 - 5855
  • [39] Simultaneous Regulation of Multiple Flow Rates for Power Generation Control of OTEC Plant Using Double-stage Rankine Cycle
    Matsuda, Yoshitaka
    Oouchida, Riku
    Sugi, Takenao
    Goto, Satoru
    Morisaki, Takafumi
    Yasunaga, Takeshi
    Ikegami, Yasuyuki
    2018 57TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2018, : 983 - 988
  • [40] Multi-criteria fuzzy comprehensive evaluation in interval environment with dual preferences
    Fan, Liu
    Spirkova, Jana
    Mesiar, Radko
    Yager, Ronald R.
    Jin, LeSheng
    JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2020, 39 (01) : 1361 - 1369