Seismic performance and damage analysis of steel-PVA hybrid fiber cementitious composites encased CFST columns

被引:2
|
作者
Li, Wei [1 ,2 ]
Wang, Zhexiong [1 ,3 ]
Li, Linfeng [1 ,4 ]
Sun, Linzhu [1 ,2 ]
机构
[1] Wenzhou Univ, Coll Civil Engn & Architecture, Wenzhou 325035, Peoples R China
[2] Key Lab Engn & Technol Soft Soil Fdn & Tideland Re, Wenzhou 325035, Peoples R China
[3] Wenzhou Engn Tech Res Ctr Bldg Energy Conservat &, Wenzhou 325035, Zhejiang, Peoples R China
[4] Zhejiang Collaborat Innovat Ctr Tideland Reclamat, Wenzhou 325035, Zhejiang, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2024年 / 86卷
基金
中国国家自然科学基金;
关键词
Hybrid fiber; CFST; Damage index; Seismic performance; Second -order effect; REINFORCED-CONCRETE; STUB COLUMNS; MECHANICAL-PROPERTIES; HYSTERETIC BEHAVIOR; FLEXURAL BEHAVIOR; SUSTAINED LOAD; STRENGTH; COMPRESSION; CAPACITY; FRACTURE;
D O I
10.1016/j.jobe.2024.108771
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Using axial compression ratio, core concrete strength, steel tube thickness, and SPC strength as research variables, cyclic loading tests were conducted on 12 steel-polyvinyl alcohol (PVA) hybrid fiber cementitious composites (SPC) encased concrete-filled steel tube(CFST)columns to study the seismic performance of specimens under earthquake action, including failure mode, strength, stiffness, ductility, energy dissipation, and second-order effects. According to the study's findings, fiber bridging enabled SPC-encased CFST columns to effectively prevent cracks and maintain high integrity even after failing. The axial compression ratio, core concrete strength, and lateral bearing capacity were positively correlated, with a maximum bearing capacity increase of 46.9%, but their deformation capacity had decreased to varying degrees. The thickness and SPC strength of the steel tube exhibited excellent performance in terms of deformation capacity and energy consumption, with a maximum ductility coefficient of 6.21. In the overall statistical analysis of research variables, it was found that composite columns with core concrete strength grades higher than outer SPC strength had better seismic performance compared to other specimens. This article proposed an improved Park-Ang damage model that effectively evaluates the damage status of SPC-encased CFST columns. The model complies with the boundary conditions of the composite column, and the damage development trend reflected is consistent with experimental phenomena.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Compressive behaviour of engineered cementitious composites and concrete encased steel composite columns
    Khan, M. K., I
    Rana, Mohammad M.
    Zhang, Y. X.
    Lee, C. K.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 167
  • [22] Numerical Modeling of Interface Bond Behavior Between Hybrid Steel-PVA Fiber-Reinforced Engineered Cementitious Composite and Concrete
    Qasim, M.
    Lee, C. K.
    Zhang, Y. X.
    INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS, 2024, 21 (08)
  • [23] Seismic performance of RC columns with encased prefabricated high-strength CFST core
    Sun, Dongde
    Yang, Yong
    Xue, Yicong
    Yu, Yunlong
    An, Kang
    Chen, Yang
    STEEL AND COMPOSITE STRUCTURES, 2021, 39 (06): : 723 - 736
  • [24] Bond performance of GFRP bars embedded in steel-PVA hybrid fiber concrete subjected to repeated loading
    Xiao, Liangli
    Dai, Siyuan
    Jin, Qingping
    Peng, Shuang
    STRUCTURAL CONCRETE, 2023, 24 (01) : 1597 - 1611
  • [25] Cyclic tests and finite element analysis on hybrid fiber-cement-based composite encased CFST columns
    Li, Wei
    Wang, Zhexiong
    Li, Linfeng
    Sun, Linzhu
    STRUCTURES, 2023, 58
  • [26] Experimental Investigation on Compressive Toughness of the PVA-Steel Hybrid Fiber Reinforced Cementitious Composites
    Liu, Wenlin
    Han, Jianping
    FRONTIERS IN MATERIALS, 2019, 6
  • [27] Seismic Performance of Steel Braces Jointed with High Performance Fiber Reinforced Cementitious Composites and Steel Bars
    Yang, Ilseung
    Kim, Soonchul
    Choi, Sungmo
    Nishiyama, Isao
    Yun, Hyundo
    ADVANCES IN STRUCTURAL ENGINEERING, 2010, 13 (06) : 1115 - 1127
  • [28] Seismic damage performance levels for concrete encased steel columns using acoustic emission tests and finite element analysis
    Yue, Jianguang
    Qian, Jiang
    Beskos, Dimitri E.
    ENGINEERING STRUCTURES, 2019, 189 : 471 - 483
  • [29] Numerical modelling of engineered cementitious composites-concrete encased steel composite columns
    Khan, M. K., I
    Lee, C. K.
    Zhang, Y. X.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 170
  • [30] Seismic performance of assembly joints between HSPC beams and concrete-encased CFST columns
    Feng, Shuaike
    Guan, Dongzhi
    Guo, Zhengxing
    Liu, Zhongxiang
    Li, Guojian
    Gong, Changyi
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 180