Cyclic shear loading test and strength evaluation on roof bearings

被引:0
|
作者
Ito K. [1 ,2 ]
Yamashita T. [3 ]
Watanabe S. [2 ,4 ]
机构
[1] Architecture Program in Graduate School, Kogakuin University
[2] School of Architecture, Kogakuin University
来源
Journal of Structural and Construction Engineering | 2019年 / 84卷 / 759期
关键词
Anchor bolt; Beam on elastic foundation theory; Cyclic shear test; Generalized plastic hinge theory; Roofbearing;
D O I
10.3130/aijs.84.649
中图分类号
学科分类号
摘要
In 2011, some roof bearings of gymnasiums suffered severe damage by the pacific coast of Tohoku earthquake. Typical damage was the elongation and break of the anchor bolts or crush of base mortar. Since gymnasiums are used as shelters for the neighboring residents in earthquake disasters, damage prevention of roof bearings are required. Roof bearings are the connections between the lower RC frame and the steel roof. They are similar to conventional steel exposed column bases. However, the dominant stress and the mechanism to resist the horizontal forces of the roof bearings are different from those of steel exposed column bases. The dominant stress of steel exposed column bases is axial and bending stress while shear stress of the anchor bolts is dominant for roof bearings since the vertical load is extremely lower than that in steel exposed column bases in ordinary buildings. In present paper, the full-scale cyclic shear loading tests of roof bearings were carried out to investigate the fracture behavior of roof bearings and the restoring force characteristics were also evaluated. Three different height (20mm, 50mm or 100mm) of the base mortar were used to compare the fracture behavior and the restoring force characteristics. Moreover, the friction tests were conducted to investigate the friction coefficient between the base mortar and base plate. It was found from the results of friction tests that the friction coefficient between the base mortar and the base plate was about 0.5. This result agrees very well with the friction coefficient given in the AIJ recommendation for Design of Connections in Steel Structures. The fracture behavior and the restoring force characteristics of roof bearings are summarized as follows. The anchor bolts were leaned after the base plate contacted the anchor bolts. After that, the base mortar cracked since the deformed anchor bolts pushed it out. After the tests, the base mortar was crushed especially outside of anchor bolts. When the base mortar height is 100mm, the test body couldn't support the vertical load since the base mortar located in inside of anchor bolts was crushed. However, the friction coefficient of base mortar was approximately 0.5, and we assumed that the restoring force characteristics of roof bearings is the summation of strength of anchor bolts and the friction force between the base mortar and base plate. The anchor bolts and the base mortar were already severely damaged before the horizontal load reached the yield shear strength. Meanwhile, we observed that the anchor bolts were bended at two parts, the bottom of the base plate and the slightly below of the surface of the concrete. For the small deformation, we proposed that the restoring force characteristics of roof bearings is evaluated by the yield bending strength considering this bending mechanism. For the large deformation, we proposed that the restoring force characteristics of roof bearings is evaluated by considering the bending and axial stress of anchor bolts. These stress of anchor bolts were calculated by the generalized plastic hinge theory applying kinematic hardening. © 2019 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:649 / 657
页数:8
相关论文
共 50 条
  • [41] Shear Bond Strength of Four Types of Orthodontic Retainers after Thermocycling and Cyclic Loading
    Golshah, A.
    Simkooei, Z. Amiri
    INTERNATIONAL JOURNAL OF DENTISTRY, 2021, 2021
  • [42] Strength and drift capacity of squat recycled concrete shear walls under cyclic loading
    Peng, Youkai
    Wu, Hui
    Yan Zhuge
    ENGINEERING STRUCTURES, 2015, 100 : 356 - 368
  • [43] Experimental Study on Shear Strength of Sand under High-frequency Cyclic Loading
    Shan Y.
    Chen P.
    Zhou S.
    Ye W.
    Dai N.
    Tiedao Xuebao/Journal of the China Railway Society, 2023, 45 (08): : 147 - 155
  • [44] Use of Pore Pressure Response to Determine Shear Strength Degradation from Cyclic Loading
    Ajmera, Beena
    Tiwari, Binod
    Pandey, Pavitra
    GEOTECHNICAL FRONTIERS 2017: SEISMIC PERFORMANCE AND LIQUEFACTION, 2017, (281): : 19 - 26
  • [45] Study on the variation regularity of shear strength of saturated soft clay under cyclic loading
    Wang, Xiaoping
    Wu, Jianqi
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 2388 - 2391
  • [46] Strength and Behavior of Reinforced Concrete Squat Shear Walls with Openings under Cyclic Loading
    Sivaguru, V
    Rao, G. Appa
    ACI STRUCTURAL JOURNAL, 2021, 118 (05) : 235 - 250
  • [47] Shear strength of reinforced soil interface under normal cyclic loading and its prediction
    Wang, Jun
    Zhu, Chen
    Liu, Fei-Yu
    Kong, Jian-Jie
    Yao, Jia-Min
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 5 (954-960): : 954 - 960
  • [48] Effect of cyclic thermal loading on the inplane shear strength of fiber reinforced MMC's
    Jansson, S
    Leckie, F
    EUROPEAN JOURNAL OF MECHANICS A-SOLIDS, 1997, 16 (04) : 561 - 572
  • [49] Cyclic loading tests and shear strength of steel reinforced recycled concrete short columns
    Ma, Hui
    Xue, Jianyang
    Liu, Yunhe
    Zhang, Xicheng
    ENGINEERING STRUCTURES, 2015, 92 : 55 - 68
  • [50] Shear strength model of reinforced-concrete exterior joint under cyclic loading
    Faculty of Civil Engineering, Ton Duc Thang University, Ho Chi Minh, Viet Nam
    不详
    NSW, Australia
    Proc. Inst. Civ. Eng. Struct. Build., 1600, 8 (603-617):