High fidelity modeling of pumped storage units for optimal operation of a multi-energy co-generation system

被引:0
|
作者
Liang, Ganggang [1 ]
Zhang, Hao [1 ,2 ]
Li, Chenxi [1 ]
Wu, Xin [1 ]
Guo, Pengcheng [1 ,2 ]
Nan, Haipeng [1 ]
机构
[1] School of Water Resources and Hydroelectric Engineering, Xi'an University of Technology, Xi'an,710048, China
[2] State Key Laboratory of Eco-Hydraulics in Northwest Arid Region, Xi'an University of Technology, Xi'an,710048, China
基金
中国国家自然科学基金;
关键词
Application level - Cogeneration systems - Engineering application level optimal operation model - Engineering applications - High-fidelity modeling - Multi energy - Multi-energy co-generation system - Multi-objectives optimization - Operations Modeling - Optimal operation - Pumping storage hydropower;
D O I
暂无
中图分类号
学科分类号
摘要
Pumped storage, as the storage technology with the largest installed capacity and mature technology, plays a key regulation role in the multi-energy co-generation system. The core of regulation accuracy is the high-fidelity modeling of pumped storage. This paper improves the insufficiency of the conventional pumped storage model (CPSM) in exaggerating the flexibility of pumped storage units by setting up non-operable operating condition regions, and incorporates the condition switching loss into the model consideration, on the basis of which a high fidelity pumped storage model (HFPSM) is established. Secondly, a multi-objective function of the operation model is set from the consideration of economy, environmental protection and stability, and a engineering application level optimal operation model of wind power-photovoltaic-thermal power-pumped storage multi-energy co-generation system based on HFPSM is proposed. Thirdly, two research indicators, the thermal power volatility indicator and the pumped storage unit utilization rate, are proposed. Fourthly, combined with examples, the effects of CPSM and HFPSM on the optimized operation of the system are investigated. It is found that adding four 50MW pumped storage units to the system can reduce the total operating cost by 10.34% and the environmental cost by 83.61%. The optimization of the high fidelity model is better under the premise of ensuring safe, stable and efficient operation of the system. Optimizing the number of unit startups and shutdowns for the high fidelity model to 25.8% of the conventional model. Finally, by exploring the optimal operation of a multi-energy co-generation system with different pumped storage installed capacities, it is found that the proposed high fidelity model makes the optimization results more in line with the actual operation. The flexibility of the pumped storage units no longer increases with the increase of installed capacity, which provides a reference for the planning of the storage capacity in the multi-energy co-generation system. © 2024 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [21] Optimal Scheduling of Island Microgrids with Seawater Pumped Storage Plants for Multi-Energy Complementarity
    Su, Shiwei
    Chai, Huarui
    Lin, Jianbo
    Yi, Chengming
    Li, Xin
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2025, 20 (02) : 185 - 196
  • [22] Optimal Operation of a Smart Multi-Energy System Considering Demand Response
    Noorzad, Najmuddin
    Tascikaraoglu, Akin
    Gurleyuk, Sirri Sunay
    Erdinc, Ozan
    Catalao, Joao P. S.
    2022 INTERNATIONAL CONFERENCE ON SMART ENERGY SYSTEMS AND TECHNOLOGIES, SEST, 2022,
  • [23] Optimal Design and Operation of an Integrated Multi-Energy System for Smart Cities
    van Beuzekom, I.
    Mazairac, L. A. J.
    Gibescu, M.
    Slootweg, J. G.
    2016 IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON), 2016,
  • [24] Interval Model Based Optimal Operation of Multi-energy Complementary System
    Bao W.
    Wei G.
    Liu J.
    Li Y.
    Gong B.
    He C.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (11): : 8 - 16
  • [25] Agent-Based Optimal Cooperative Operation of Multi-energy System
    Xu, Bohan
    Xiang, Yue
    Pan, Li
    Fang, Mengqiu
    Liu, Junyong
    Liu, Youbo
    Wang, Tianhao
    2021 IEEE IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA (IEEE I&CPS ASIA 2021), 2021, : 520 - 525
  • [26] Optimal Operation of Combined Wind Power Generation and Pumped-Storage Units in the Electricity Markets
    Aghajani, S.
    Kalantar, M.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (05): : 2385 - 2391
  • [27] Multi-Scheme Optimal Operation of Pumped Storage Wind-Solar-Thermal Generation System Based on Tolerable Energy Abandonment
    Zhang, Hao
    Wu, Shuai
    Li, Huanhuan
    Zhang, Jie
    Zhu, Chao
    Zhou, Hekuan
    Jia, Yaofei
    WATER, 2024, 16 (04)
  • [28] Multi-Energy Storage System and Islanded Optimal Dispatch Method of CCHP
    Chen P.
    Feng W.
    Sun K.
    Zhang C.
    Sun B.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (15): : 3231 - 3243
  • [29] Multi-fuel cell energy system for telecommunications co-generation system
    Kuwata, Y
    Take, T
    Aoki, T
    Ogata, T
    INTELEC - EIGHTEENTH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, 1996, : 676 - 683
  • [30] Optimal Operation Strategy of Multi-energy System Considering Energy Supply for Waste Treatment
    Li Guangdi
    Xu Guoyi
    Zhou Bowen
    Hu Jinpeng
    Zhao Ying
    2022 4TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2022), 2022, : 395 - 402