Analysis and Control of Cascaded Energy Storage System for Energy Efficiency and Power Quality Improvement in Electrified Railways

被引:32
|
作者
Chen, Junyu [1 ]
Zhao, Yue [2 ]
Lin, Hongjian [3 ]
Wei, Yuqi [4 ]
Liu, Wenqiang [5 ,6 ]
Guo, Qi [2 ]
Li, Yunwei Ryan [7 ]
Mantooth, H. Alan [8 ]
机构
[1] Hong Kong Polytech Univ, Dept Elect & Elect Engn, Hong Kong, Peoples R China
[2] Inner Mongolia Elect Power Res Inst Co Ltd, Hohhot 010020, Peoples R China
[3] City Univ Hong Kong, Dept Elect Engn, Hong Kong, Peoples R China
[4] Xi An Jiao Tong Univ, Sch Elect Engn, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[5] Hong Kong Polytech Univ, Shenzhen Res Inst, Hong Kong, Peoples R China
[6] Hong Kong Polytech Univ, Chinese Natl Rail Transit Electrificat & Automat, Hong Kong, Peoples R China
[7] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2V4, Canada
[8] Univ Arkansas, Dept Elect Engn, Fayetteville, AR 72701 USA
基金
中国国家自然科学基金;
关键词
Reactive power; Rail transportation; Power quality; Energy storage; Load flow; Transformers; Energy efficiency; Electrified railway; energy efficiency; energy storage system (ESS); power flow control strategy; power quality; regenerative braking energy (RBE); MODULAR MULTILEVEL CONVERTER; CONTROL STRATEGY; CONDITIONER; STATE; MODEL;
D O I
10.1109/TTE.2023.3287891
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Energy-efficient and grid-friendly railway power system (RPS) is critical for the sustainable development of electrified railways. In this article, a cascaded energy storage system (CESS) is investigated for energy efficiency and power quality improvement of the RPS. First, the detailed operation principles of the CESS for multiple control objectives, including regenerative braking energy (RBE) utilization, reactive power compensation, and negative sequence current (NSC) suppression, are analyzed. On this basis, a hierarchical power flow control strategy is developed for achieving the power flow management and control of multiple objectives for CESS. Specifically, a multiobjective power flow management strategy is designed in the system layer to allocate the power references for the CESS under sufficient and insufficient capacity scenarios (ICS). In the sufficient capacity scenario (SCS), the power references are directly obtained by the operation principles. In the ICS, the power references are allocated through a three-stage optimization method considering the power shaving rate, grid power factor, and grid imbalance degree. Subsequently, the power references from the system layer are tracked in the converter layer to achieve power flow control. Finally, the effectiveness of the proposed hierarchical power flow control strategy is verified through experimental results. The results show that the proposed CESS can achieve superior performance on RBE utilization and power quality improvement under complex operating conditions in electrified railways.
引用
收藏
页码:1299 / 1313
页数:15
相关论文
共 50 条
  • [41] Energy Storage System Based on Cascaded Multilevel Inverter with Decoupled Energy Balancing Control
    Cao, Yuanzhi
    Lu, Junfen
    Zhuang, Jun
    Li, YueLong
    Jiang, Wei
    Zhao, Hui
    2015 7TH INTERNATIONAL CONFERENCE ON MECHANICAL AND ELECTRONICS ENGINEERING (ICMEE 2015), 2015, 31
  • [42] Combined Operation of an Unified Power Quality Conditioner and a Superconducting Magnetic Energy Storage System for Power Quality Improvement
    Amaro, Nuno
    Casimiro, Luis
    Pina, Joao Murta
    Martins, Joao
    Ceballos, Jose M.
    TECHNOLOGICAL INNOVATION FOR CLOUD-BASED ENGINEERING SYSTEMS, 2015, 450 : 374 - 382
  • [43] Power quality improvement in distribution network using DSTATCOM with battery energy storage system
    Mahela, Om Prakash
    Shaik, Abdul Gafoor
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 83 : 229 - 240
  • [44] Interconnection of electrical energy storage systems for power quality improvement
    Brenna, M.
    Lazaroiu, G. C.
    Rotaru, R.
    Tironi, E.
    2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 3160 - +
  • [45] Sensorless Control for Wind Energy Conversion System (WECS) With Power Quality Improvement
    Benadja, Mounir
    Chandra, Ambrish
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [46] Control of a wind energy conversion system equipped by a STACOM for power quality improvement
    Abdelouahed, Touhami
    Ahmed, Zidi Sid
    Hadjeri, Samir
    PROCEEDINGS OF 2016 8TH INTERNATIONAL CONFERENCE ON MODELLING, IDENTIFICATION & CONTROL (ICMIC 2016), 2016, : 115 - 121
  • [47] Dynamic Voltage Unbalance Constrained Economic Dispatch for Electrified Railways Integrated Energy Storage
    Chen, Yinyu
    Chen, Minwu
    Liang, Zongyou
    Liu, Li
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2022, 18 (11) : 8225 - 8235
  • [48] Power conditioning system control strategy for cascaded H-bridge converter battery energy storage system
    Hasabelrasul, Hashim
    Yan, Xiangwu
    Gadalla, Abuzaid Saeed
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 663 - 667
  • [49] Control Design of a STATCOM with Energy Storage System for Stability and Power Quality Improvements
    Kuiava, R.
    Ramos, R. A.
    Bretas, N. G.
    2009 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-3, 2009, : 172 - 177
  • [50] Design of Energy Storage Control Strategy to Improve the PV System Power Quality
    Lei, Mingyu
    Yang, Zilong
    Wang, Yibo
    Xu, Honghua
    Meng, Lexuan
    Vasquez, Juan C.
    Guerrero, Josep M.
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 2022 - 2027