Monoaxial Screws Versus Polyaxial Screws Osteosynthesis for Unstable Atlas Fractures: A Retrospective, Comparative Study With a Minimum Follow-Up of 3 years

被引:0
|
作者
Niu, He-Gang [1 ]
Zhao, Cheng-Kun [1 ]
Yang, Kun [1 ]
Tao, Hui [1 ]
Liu, Chang [1 ]
Zhang, Jing-Jing [1 ]
Shen, Cai-Liang [1 ]
Zhang, Yin-Shun [1 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Orthoped, 218 Jixi Rd, Hefei 230022, Anhui, Peoples R China
关键词
atlas fracture; open reduction and internal fixation (ORIF); polyaxial screws; monoaxial screws; cervical; LATERAL MASS SCREWS; FUNCTION-PRESERVING OPTION; C1; FIXATION; REDUCTION; CLASSIFICATION; MANAGEMENT;
D O I
10.1177/21925682241247489
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design Retrospective cohort study.Objective The study aimed to compare the radiological parameters, clinical outcomes, and long-term effects of the posterior osteosynthesis with polyaxial screw-rod system and the monoaxial screw-rod system in the treatment of unstable atlas fractures.Methods We retrospectively analyzed the clinical data of 33 patients with posterior ORIF for unstable atlas fractures in our hospital from August 2013 to June 2020, with a minimum of 3 years of follow-up. Polyaxial screws (group A) were used in 12 patients and monoaxial screws (group B) in 21 patients. Perioperative data, radiological parameters, and clinical outcomes were collected and compared between the 2 surgical approaches.Results The operative time, blood loss, time of screw-rod system placement, and hospital stay were significantly lower in group A than in group B. At the last follow-up, the visual analog scale (VAS) score and anterior arch reduction rate of the atlas in group A were lower than those in group B, while the lateral mass displacement (LMD) in group A was higher than that in group B. There was no significant difference between Group A and Group B in terms of the anterior atlantodental interval (AADI), posterior arch reduction rate of the atlas, range of motion (ROM), and neck disability index (NDI).Conclusions Monoaxial screws can achieve better reduction results for unstable atlas fractures, especially for the anterior arch of atlas. However, the surgical operation of monoaxial screws is more complicated than that of polyaxial screws and has more complications. Appropriate implants should be selected for the treatment of unstable atlas fractures based on the type of atlas fracture, the experience of surgeons, and the demands of patients.
引用
收藏
页码:31 / 40
页数:10
相关论文
共 50 条
  • [31] Four-corner fusion: Clinical and radiological outcome after fixation by headless compression screws or dorsal locking plate at minimum 5 years' follow-up
    d'almeida, Marc-Antoine
    Sturbois-Nachef, Nadine
    Amouyel, Thomas
    Chantelot, Christophe
    Saab, Marc
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (05)
  • [32] Segmental pedicle screws instrumentation and fusion to L5 for spinal deformity secondary to Duchenne muscular dystrophy: results with a minimum of 2 years follow-up
    Masashi Takaso
    Toshiyuki Nakazawa
    Takayuki Imura
    Takamitsu Okada
    Masaki Ueno
    Kensuke Fukushima
    Wataru Saito
    Atushi Sasaki
    Hiroyuki Sakagami
    Makihito Okamoto
    Takashi Masaki
    Hirotsugu Okamoto
    Toshiyuki Okutomi
    Masahiro Ishii
    Yasuhisa Ueda
    European Journal of Orthopaedic Surgery & Traumatology, 2010, 20 : 453 - 461
  • [33] Letter to the Editor: Cemented versus uncemented hemiarthroplasty for femoral neck fractures in patients with neuromuscular diseases: a minimum of 2 years’ follow-up study
    Wang Xing
    Huang Qiang
    Pei Fuxing
    Journal of Orthopaedic Surgery and Research, 16
  • [34] Letter to the Editor: Cemented versus uncemented hemiarthroplasty for femoral neck fractures in patients with neuromuscular diseases: a minimum of 2 years' follow-up study
    Xing, Wang
    Qiang, Huang
    Fuxing, Pei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [35] Ceramic-on-ceramic versus ceramic-on-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up
    Malerba Giuseppe
    Basilico Mattia
    Bonfiglio Nadia
    Vitiello Raffaele
    Ruberto Pasquale
    D’ Adamio Stefano
    Sirgiovanni Mattia
    De Santis Vincenzo
    Maccauro Giulio
    BMC Musculoskeletal Disorders, 22
  • [36] Ceramic-on-ceramic versus ceramic-on-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up
    Giuseppe, Malerba
    Mattia, Basilico
    Nadia, Bonfiglio
    Raffaele, Vitiello
    Pasquale, Ruberto
    Stefano, D' Adamio
    Mattia, Sirgiovanni
    Vincenzo, De Santis
    Giulio, Maccauro
    BMC MUSCULOSKELETAL DISORDERS, 2022, 22 (SUPPL 2)
  • [37] Ring versus non-ring plate for the treatment of displaced scapular body fractures: a retrospective study with a mean follow-up of 5 years
    Yuan, Zheng
    Zhang, Fan
    Liang, Guanzhao
    Zeng, Xianshang
    Liu, Dan
    Yang, Chen
    Yu, Weiguang
    Zhang, Qiang
    Zhang, Xinchao
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (07) : 2731 - 2742
  • [38] Long-Term Functional Results of Intra- and Extra-Articular Hand Fractures Treatment With Titanium Miniature Plates and Screws With Minimum Follow-Up of 24 Months
    Varitimidis, Sokratis
    Dailiana, Zoe
    Agorastakis, Dimitrios
    Fyllos, Apostolos
    Zibis, Aristeidis
    Hantes, Michael
    Malizos, Konstantinos
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (06)
  • [39] Vertebroplasty Using Calcium Phosphate Cement for Osteoporotic Vertebral Fractures: Study of Outcomes at a Minimum Follow-up of Two Years
    Nakano, Masato
    Hirano, Norikazu
    Zukawa, Mineyuki
    Suzuki, Kayo
    Hirose, Jinichiro
    Kimura, Tomoatsu
    Kawaguchi, Yoshiharu
    ASIAN SPINE JOURNAL, 2012, 6 (01) : 34 - 42
  • [40] Tendon interposition arthroplasty versus arthrodesis for the treatment of trapeziometacarpal arthritis: A retrospective comparative follow-up study
    Mureau, MAM
    Rademaker, RPC
    Verhaar, JAN
    Hovius, SER
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (05): : 869 - 876