The rationale for FLEX (cochlear implant) electrode with varying array lengths

被引:14
|
作者
Dhanasingh, Anandhan [1 ]
机构
[1] MED El GmbH, Furstenweg 77a, A-6020 Innsbruck, Austria
来源
WORLD JOURNAL OF OTORHINOLARYNGOLOGY-HEAD & NECK SURGERY | 2021年 / 7卷 / 01期
关键词
Cochlear duct length; Cochlear anatomy; Cochlear volume; Scala tympani cross-sectional dimensions; SCALA TYMPANI; SIZE; PLACEMENT;
D O I
10.1016/j.wjorl.2019.12.003
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
With cochlear implantation (CI) being the standard of care for profoundly deaf cases, more and more patients with low frequency residual hearing are currently being treated with CI. In view of preserving the residual hearing, the ultimate aim of both the surgeons and the CI companies is to achieve zero-degree of electrode insertion trauma. Variations in the size and shape of cochlea, cross-sectional dimensions of ST, electrode insertion techniques with and without metal stylet rod and the experience level of the operating surgeons, all play a role in the electrode array related insertion trauma. An effective electrode design must include flexible array to accommodate the cochlear shape variation, electrode with variety of array lengths to support the concept of cochlear size specific electrode array and finally smaller cross-sectional dimensions of electrode array in matching the cross-sectional dimensions of ST. As per published reports, FLEX electrode array design offers minimal degree of electrode insertion trauma along with the possibility of patient specific electrode array length matching their cochlear size. Looking at the cross-sectional dimensions of FLEX electrode array along with its volume, it appear to be highly safe to the cochlea by not taking too much volume inside the ST. To offer additional support, otological pre-planning software tool like OTOPLAN is now clinically available in measuring the cochlear size in finding the best electrode array match along with the possibilities of anatomy based post-operative speech processor fitting. Copyright (c) 2020 Chinese Medical Association. Publishing services by Elsevier B.V. on behalf of KeAi Communications Co. Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:45 / 53
页数:9
相关论文
共 50 条
  • [21] Fixation of the cochlear implant electrode array with homologous fibrin glue
    Facer, GW
    COCHLEAR IMPLANTS, 1996, : 191 - 200
  • [22] An improved cochlear implant electrode array for use in experimental studies
    Shepherd, Robert
    Verhoeven, Kristien
    Xu, Jin
    Risi, Frank
    Fallon, James
    Wise, Andrew
    HEARING RESEARCH, 2011, 277 (1-2) : 20 - 27
  • [23] Development and Clinical Introduction of the Nurotron Cochlear Implant Electrode Array
    Rebscher, Stephen
    Zhou, David Daomin
    Zeng, Fan-Gang
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2018, 14 (03): : 392 - 400
  • [24] Insertion trauma of a cochlear implant electrode array with Nitinol inlay
    Thomas S. Rau
    Lenka Harbach
    Nick Pawsey
    Marcel Kluge
    Peter Erfurt
    Thomas Lenarz
    Omid Majdani
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 3573 - 3585
  • [25] Determination of the curling behavior of a preformed cochlear implant electrode array
    Rau, Thomas S.
    Majdani, Omid
    Hussong, Andreas
    Lenarz, Thomas
    Leinung, Martin
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2011, 6 (03) : 421 - 433
  • [26] COCHLEAR IMPLANT ELECTRODE
    CLARK, GM
    HALLWORTH, RJ
    ZDANIUS, K
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1975, 89 (08): : 787 - 792
  • [27] Cochlear implant electrode array tip-foldover detection by electrode voltage telemetry
    Leblans, Marc
    Zarowski, Andrzej
    Molisz, Andrzej
    van Dinther, Joost
    Dedeyne, Janne
    Lerut, Bob
    Kuhweide, Rudolf
    Offeciers, Erwin
    COCHLEAR IMPLANTS INTERNATIONAL, 2023, 24 (02) : 95 - 106
  • [28] Neural excitation patterns of four cochlear implant electrode array configurations
    Choi, CTM
    Chen, YP
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 269 - 270
  • [29] Psychophysics of a prototype peri-modiolar cochlear implant electrode array
    Cohen, LT
    Saunders, E
    Clark, GM
    HEARING RESEARCH, 2001, 155 (1-2) : 63 - 81
  • [30] Shape optimization of cochlear implant electrode array using genetic algorithms
    Choi, CTM
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 1445 - 1448