Determination of the dose rate from the pulse-height spectra of an airborne gamma-ray spectrometer based on an unmanned aerial vehicle

被引:0
|
作者
Gavrilov, S. L. [1 ]
Pimenov, A. E. [1 ]
Shvedov, A. M. [1 ]
Aron, D. V. [1 ]
Dyakov, S. V. [1 ]
机构
[1] RAS, IBRAE, Moscow, Russia
关键词
621.039+51-73;
D O I
10.1007/s10512-024-01084-w
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In the present study, data for converting the pulse-height spectra of an airborne gamma-ray spectrometer with a NaI (31 x 31 mm) detector to the dose rate values were obtained using the mathematical simulation. The results were tested using model tasks for determining pulse-height spectra at heights from 15 to 75 m. A point isotropic source of 60Co and the infinite contamination of the soil surface with 137Cs were considered as sources of gamma-radiation. The simulation was carried out using the Monte Carlo method. As a result, uncertainties of obtained conversion coefficients for dose rate estimations were evaluated.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [31] MODIFICATION OF THE SIMPLE-MODEL FOR THE PREDICTION OF PULSE-HEIGHT SPECTRA FOR GAMMA-RAY ENERGIES GREATER THAN 1.5 MEV
    PORELLI, A
    GARDNER, RP
    NUCLEAR INSTRUMENTS & METHODS, 1979, 159 (01): : 177 - 179
  • [32] Performance of an air sampler and a gamma-ray detector in a small unmanned aerial vehicle
    Roy Pöllänen
    Harri Toivonen
    Kari Peräjärvi
    Tero Karhunen
    Petri Smolander
    Tarja Ilander
    Kimmo Rintala
    Tuure Katajainen
    Jarkko Niemelä
    Marko Juusela
    Timo Palos
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 282 : 433 - 437
  • [33] GAMMA-RAY SPECTROMETRY WITH SOLID-STATE DETECTORS BY CURRENT PULSE-HEIGHT ANALYSIS
    SZYMCZYK, WM
    DABROWSKI, AJ
    IWANCZYK, JS
    KUSMISS, JH
    HUTH, GC
    HULL, K
    BEYERLE, A
    MARKAKIS, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 213 (01): : 115 - 122
  • [34] Performance of an air sampler and a gamma-ray detector in a small unmanned aerial vehicle
    Pollanen, Roy
    Toivonen, Harri
    Perajarvi, Kari
    Karhunen, Tero
    Smolander, Petri
    Ilander, Tarja
    Rintala, Kimmo
    Katajainen, Tuure
    Niemela, Jarkko
    Juusela, Marko
    Palos, Timo
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (02) : 433 - 437
  • [35] Development of an airborne gamma-ray spectrometer based on a CZT detector
    Joung, S.
    Ji, Y-Y
    Choi, Y.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (10):
  • [36] Automatic Building and Height Determination from Unmanned Aerial Vehicle Data
    Kaya, Efdal
    Erener, Arzu
    ADVANCES IN REMOTE SENSING AND GEO INFORMATICS APPLICATIONS, 2019, : 163 - 166
  • [37] Degenerate Pile-up Correction in Pulse Height Spectra from Gamma-ray Spectrometers
    Marcer, Giulia
    Dal Molin, Andrea
    Rebai, Marica
    Rigamonti, Davide
    Tardocchi, Marco
    JOURNAL OF FUSION ENERGY, 2024, 43 (01)
  • [38] PEAK SEARCHING GAMMA-RAY PULSE HEIGHT SPECTRA - AN EXAMPLE OF NONLINEAR ANALYSIS
    NICHOLSO.WL
    HOOPER, RL
    BIOMETRICS, 1966, 22 (04) : 955 - &
  • [39] SIMPLE-MODEL FOR PREDICTION OF GAMMA-RAY PULSE-HEIGHT SPECTRA FOR RIGHT-CIRCULAR CYLINDRICAL SODIUM IODIDE CRYSTAL DETECTORS
    GARDNER, RP
    NUCLEAR INSTRUMENTS & METHODS, 1976, 138 (02): : 287 - 291
  • [40] Application of Support Vector Regression in Removing Poisson Fluctuation from Pulse Height Gamma-Ray Spectra
    Alamaniotis, Miltiadis
    Hernandez, Hermilo
    Jevremovic, Tatjana
    2013 FOURTH INTERNATIONAL CONFERENCE ON INFORMATION, INTELLIGENCE, SYSTEMS AND APPLICATIONS (IISA 2013), 2013, : 18 - 21