Activated sludge;
Automobile industry wastewater;
Compatibility study;
Matrix effect correction;
Municipal wastewater treatment plant;
WATER TREATMENT-PLANT;
DEGRADATION;
PERFORMANCE;
BACTERIA;
BULKING;
D O I:
10.1007/s13762-024-05608-6
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
The on-site-treated effluent from an automobile manufacturing company is discharged into the public sewage system for further treatment. However, the upgrade of the treatment plant to reduce the effluent pollutant load led to the discharge limit for phenols being occasionally exceeded. The concern of the water authority prompted a study to investigate whether the toxicity of phenols could affect the performance of the receiving municipal wastewater treatment plant. To this end, mixtures of the industrial effluent and synthetic municipal wastewater were tested in a laboratory-scale activated sludge system. The bioreactor was fed with increasing ratios of the industrial wastewater in the combined influent (from 10 to 50%) over 7 months. No significant differences were observed in the system performance fed only with the synthetic wastewater (during the acclimation stage) or with the industrial wastewater. The bioreactor achieved average removal efficiencies of 70% for phenols even when half of the combined influent was the industrial wastewater. Bearing in mind the question of phenols, an important drawback was the high uncertainty in their determination by the conventional phenol index method due to the matrix effect. To overcome this a spectrophotometric procedure based on the serial dilutions of each pair of influent and effluent samples has been developed. Although strong microbial selection was observed by the changing bioreactor environment, the industrial effluent was found to be fully compatible with further treatment by conventional activated sludge process.
机构:
Osaka Univ, Div Sustainable Energy & Environm Engn, Suita, Osaka 5650871, JapanOsaka Univ, Div Sustainable Energy & Environm Engn, Suita, Osaka 5650871, Japan
Hashimoto, Kurumi
Matsuda, Masami
论文数: 0引用数: 0
h-index: 0
机构:
Osaka Univ, Div Sustainable Energy & Environm Engn, Suita, Osaka 5650871, JapanOsaka Univ, Div Sustainable Energy & Environm Engn, Suita, Osaka 5650871, Japan
Matsuda, Masami
论文数: 引用数:
h-index:
机构:
Inoue, Daisuke
Ike, Michihiko
论文数: 0引用数: 0
h-index: 0
机构:
Osaka Univ, Div Sustainable Energy & Environm Engn, Suita, Osaka 5650871, JapanOsaka Univ, Div Sustainable Energy & Environm Engn, Suita, Osaka 5650871, Japan
Xiumei DuanJiti ZhouSen QiaoXin YinTian TianFangdi Xu Key Laboratory of Industrial Ecology and Environmental EngineeringMOESchool of Environmental Science and TechnologyDalian University of TechnologyDalian China
论文数: 0引用数: 0
h-index: 0
Xiumei DuanJiti ZhouSen QiaoXin YinTian TianFangdi Xu Key Laboratory of Industrial Ecology and Environmental EngineeringMOESchool of Environmental Science and TechnologyDalian University of TechnologyDalian China