Thermal performance and applied evaluation of the pre-bored grouting planted nodular pile in warm frozen soil

被引:1
|
作者
Zhang, Qi [1 ,2 ,4 ]
Zhang, Tianqi [3 ]
Dong, Yuanhong [1 ,2 ,4 ]
Zhang, Tianyuan [5 ]
Wei, Yao [1 ,2 ,4 ]
Hao, Ruoyu [1 ,2 ,4 ]
Zhao, Nanlu [1 ,2 ,4 ]
Du, Haowei [1 ,2 ,4 ]
机构
[1] CCCC First Highway Consultants Co Ltd, Xian 710065, Peoples R China
[2] Natl Key Lab Green & Long Life Rd Engn Extreme Env, Xian 710065, Peoples R China
[3] Xijing Univ, Shaanxi Key Lab Safety & Durabil Concrete Struct, Xian 710123, Peoples R China
[4] Qinghai Huashixia Permafrost Highway Engn Safety N, Xian 710065, Peoples R China
[5] Qinghai Univ, Coll Civil Engn & Water Resources, Xining 810016, Peoples R China
基金
中国国家自然科学基金;
关键词
Warm frozen soil; The PGPN pile; Temperature field; Model experiment; Numerical analysis; PERMAFROST REGIONS; STABILITY ANALYSIS; PLACE; TEMPERATURE; FOUNDATIONS; EMBANKMENT;
D O I
10.1016/j.applthermaleng.2024.123178
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermal effect of pile foundation in frozen ground is crucial for the formation of its bearing capacity. To break through the problems of strong thermal disturbance and slow formation of bearing capacity in the existing pile foundations. In this paper, a new type of pile named Pre-bored Grouting Planted Nodular (PGPN) was first introduced to the permafrost area, which was a prefabricated composite pile. Its unique structure can reduce the amount of cementitious materials and improve the bearing capacity. To reveal the thermal performance of the PGPN pile to warm permafrost, and compare with that of bored concrete pile, the model experiment and numerical simulation of the pile were conducted in this paper. It was found that: 1) The refreezing time and thermal disturbance radius of the PGPN pile were 270 days and 1.8 m, respectively, which were one-third and half of those of cast-in-place pile. The cemented-soil around the PGPN pile could significantly reduce its hydration heat and reduce the thermal disturbance to frozen ground. 2) Because of the high cement concentration in cementedsoil, the early hydration reaction of the pile was strong, and the temporary high temperature provided a favorable environment for the strength maintenance of cemented-soil in frozen soil. On the contrary, the hydration reaction of bored concrete pile lasted a long time, which intensified the degree of thermal disturbance to permafrost; and 3) Affected by the cooling effect of the atmospheric environment and the self-recovery effect of the lower permafrost, the temperature field of the pile foundation refrozen from the upper and lower ends to the middle. The structure of the frozen soil was changed by hydration heat, making it difficult to return to its initial state. The research results can provide data support for the promotion and application of prefabricated pile foundation in permafrost regions.
引用
收藏
页数:16
相关论文
共 34 条
  • [31] Performance evaluation of post-grouting for bored piles installed in inhomogeneous gravel pebble stratum overlaid by deep and soft soil layers
    Wang, J.
    Jin, T.
    Qin, W.
    Zhang, F.
    GEOMECHANICS AND GEOENGINEERING-AN INTERNATIONAL JOURNAL, 2024, 19 (01): : 77 - 95
  • [32] Experimental investigation on the impact of the asymmetrical heat exchange and operation modes on the thermal performance of a bored energy pile in unsaturated soil: A case study in Brazil
    Formigari, Ricardo Caires
    Tsuha, Cristina de Hollanda Cavalcanti
    GEOTHERMICS, 2025, 125
  • [33] Optimal filling ratios and thermal performance of a two-phase closed thermosyphon pile in frozen soil under warming conditions
    Abweny, Mohammad A.
    Abdel-Jawad, Ammar
    Xiao, Suguang
    APPLIED THERMAL ENGINEERING, 2025, 264
  • [34] Evaluation of the Performance of a Heat Pipe for Pre-Frozen Soil around a Solar Support by a Numerical Method
    Li, Dong
    Yang, Xinpeng
    Zhao, Xuefeng
    Yang, Ruitong
    Meng, Lan
    Fu, Shaojie
    PROCESSES, 2023, 11 (01)