A low-voltage-driven MEMS ultrasonic phased-array transducer for fast 3D volumetric imaging

被引:3
|
作者
Zhang, Yun [1 ,2 ]
Jin, Tong [1 ,2 ]
Deng, Yining [1 ,2 ]
Zhao, Zijie [1 ]
Wang, Rui [3 ]
He, Qiong [3 ]
Luo, Jianwen [3 ]
Li, Jiawei [4 ]
Du, Kang [4 ]
Wu, Tao [4 ]
Yan, Chenfang [1 ,2 ]
Zhang, Hao [1 ]
Lu, Xinchao [1 ]
Huang, Chengjun [1 ,2 ]
Gao, Hang [1 ]
机构
[1] Chinese Acad Sci, Inst Microelect, Beijing 100029, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Tsinghua Univ, Sch Biomed Engn, Beijing 100084, Peoples R China
[4] ShanghaiTech Univ, Sch Informat Sci & Technol, Shanghai 201210, Peoples R China
来源
MICROSYSTEMS & NANOENGINEERING | 2024年 / 10卷 / 01期
基金
中国国家自然科学基金;
关键词
EQUIVALENT-CIRCUIT MODELS; IMPEDANCE; CELL;
D O I
10.1038/s41378-024-00755-9
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Wearable ultrasound imaging technology has become an emerging modality for the continuous monitoring of deep-tissue physiology, providing crucial health and disease information. Fast volumetric imaging that can provide a full spatiotemporal view of intrinsic 3D targets is desirable for interpreting internal organ dynamics. However, existing 1D ultrasound transducer arrays provide 2D images, making it challenging to overcome the trade-off between the temporal resolution and volumetric coverage. In addition, the high driving voltage limits their implementation in wearable settings. With the use of microelectromechanical system (MEMS) technology, we report an ultrasonic phased-array transducer, i.e., a 2D piezoelectric micromachined ultrasound transducer (pMUT) array, which is driven by a low voltage and is chip-compatible for fast 3D volumetric imaging. By grouping multiple pMUT cells into one single drive channel/element, we propose an innovative cell-element-array design and operation of a pMUT array that can be used to quantitatively characterize the key coupling effects between each pMUT cell, allowing 3D imaging with 5-V actuation. The pMUT array demonstrates fast volumetric imaging covering a range of 40 mm x 40 mm x 70 mm in wire phantom and vascular phantom experiments, achieving a high temporal frame rate of 11 kHz. The proposed solution offers a full volumetric view of deep-tissue disorders in a fast manner, paving the way for long-term wearable imaging technology for various organs in deep tissues.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Simulations and Measurements of 3-D Ultrasonic Fields Radiated by Phased-Array Transducers Using the Westervelt Equation
    Doinikov, Alexander A.
    Novell, Anthony
    Calmon, Pierre
    Bouakaz, Ayache
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (09) : 1470 - 1477
  • [22] Boundary Array Transducer and Beamforming for Low-Cost Real-time 3D Imaging
    Yen, Jesse T.
    Powis, Emily
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [23] A NEW SOFTWARE IMPLEMENTATION OF ULTRASONIC PHASED ARRAY INSPECTION AND 3D IMAGING APPLICATION BASED ON GPU PARALLEL COMPUTING
    Gao, Da-liang
    Shi, Fang-fang
    Zhang, Bi-xing
    PROCEEDINGS OF 2016 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES, AND DEVICE APPLICATIONS (SPAWDA), 2016, : 131 - 134
  • [24] 3D fluoroscopy with real-time 3D non-Cartesian phased-array contrast-enhanced MRA
    Brodsky, Ethan
    Isaacs, David
    Grist, Thomas M.
    Block, Walter F.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) : 247 - 254
  • [25] 3D ultrasound imaging in frequency domain with 1D array transducer
    Han, Zhihui
    Peng, Hu
    Lu, Putian
    ULTRASONICS, 2017, 76 : 28 - 34
  • [26] Method of improving 3D imaging resolution of APD array based on optical phased array
    Wang, Shuai
    Sun, Huayan
    Zhao, Yanzhong
    Zeng, Hairui
    Liu, Tianjian
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2019, 48 (04):
  • [27] Fully sampled matrix transducer for real time 3D ultrasonic imaging
    Savord, B
    Solomon, R
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 945 - 953
  • [28] Phased array 3D MR spectroscopic imaging of the brain at 7 T
    Xu, Duan
    Cunningham, Charles H.
    Chen, Albert P.
    Li, Yan
    Kelley, Douglas A. C.
    Mukherjee, Pratik
    Pauly, John M.
    Nelson, Sarah J.
    Vigneron, Daniel B.
    MAGNETIC RESONANCE IMAGING, 2008, 26 (09) : 1201 - 1206
  • [29] Crossed-Array Transducer for Real-Time 3D Imaging
    Joyce, Andrew W.
    Lockwood, Geoffrey R.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2116 - 2120
  • [30] 3-D flaw imaging by inverse scattering analysis using ultrasonic array transducer
    Nakahata, K.
    Saitoh, T.
    Hirose, S.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 26A AND 26B, 2007, 894 : 717 - 724