Comparison of femoral neck system versus cannulated cancellous screws for the fixation of femoral neck fracture: a single-center retrospective cohort study

被引:1
|
作者
Caldaria, A. [1 ,2 ]
Gambuti, E. [3 ,4 ]
Biagi, N. [5 ]
Spadoni, E. [3 ,4 ]
Saracco, A. [3 ,4 ]
Massari, L. [3 ,4 ]
Caruso, G. [3 ,4 ]
机构
[1] San Pietro Fatebenefratelli Hosp, Dept Orthoped & Trauma Surg, I-00189 Rome, Italy
[2] UniCamillus St Camillus Internation Univ Hlth & Me, Fac Med & Surg, I-00131 Rome, Italy
[3] Univ Ferrara, Dept Neurosci & Rehabil, Ferrara, Italy
[4] S Anna Univ Hosp Ferrara, Orthopaed & Traumatol Unit, Ferrara, Italy
[5] Univ Reading, Informat Res Ctr, Henley Business Sch, Business Informat Syst & Accounting, Reading, England
关键词
Femoral neck fracture; Cannulated cancellous screws; Femoral neck system; Internal fixation; YOUNG-ADULTS;
D O I
10.1007/s00590-024-04051-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe dynamic hip screw (DHS) and cannulated compression screws (CCS) have been the two implants most frequently employed for the fixation of femoral neck fractures. The objective of this study is to compare clinical and radiographic outcomes between patients treated with the FNS and those treated with CCS.Material and methodsWe conducted a retrospective analysis of a consecutive series of femoral neck fractures treated with FNS or CCS between May 2019 and June 2022. The study included 144 patients who met the inclusion criteria. Collected data encompassed age, sex, Garden fracture classification, Pauwels classification, duration of surgery, length of hospital stays, Harris Hip Score (HHS), complications, and injured side.ResultsThe FNS group comprised 70 patients, while the CCS group consisted of 74 patients. The operation time was 43.6 +/- 12.09 min for the FNS group and 56.47 +/- 22.42 min for the CCS group. At the end of the follow-up, the mean HHS was 87.07 +/- 11.77 for the FNS group and 76.20 +/- 13.64 for the CCS group. The mean reduction in hemoglobin levels from pre- to post-surgery was 1.05 mg/dl in the FNS group and 0.87 mg/dl in the CCS group. The reintervention rate was 8.1% for the CCS group and 2.85% for the FNS group.ConclusionThe FNS does not demonstrate superiority over CCS regarding femoral neck shortening, complication rate, and reduction in hemoglobin levels. However, FNS does appear superior to CCS in terms HHS, operation time, and reoperation rate.
引用
收藏
页码:3207 / 3213
页数:7
相关论文
共 50 条
  • [21] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Zheng Wang
    Yong Yang
    Gangning Feng
    Haohui Guo
    Zhirong Chen
    Yaogeng Chen
    Qunhua Jin
    BioMedical Engineering OnLine, 21
  • [22] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Wang, Zheng
    Yang, Yong
    Feng, Gangning
    Guo, Haohui
    Chen, Zhirong
    Chen, Yaogeng
    Jin, Qunhua
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [23] Comparison of femoral neck system to multiple cancellous screws and dynamic hip screws in the treatment of femoral neck fractures
    Xu, Xiangyu
    Fan, Jixing
    Zhou, Fang
    Lv, Yang
    Tian, Yun
    Ji, Hongquan
    Zhang, Zhishan
    Guo, Yan
    Yang, Zhongwei
    Hou, Guojin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S28 - S35
  • [24] Comparison of femoral neck system to multiple cancellous screws and dynamic hip screws in the treatment of femoral neck fractures
    Xu, Xiangyu
    Fan, Jixing
    Zhou, Fang
    Lv, Yang
    Tian, Yun
    Ji, Hongquan
    Zhang, Zhishan
    Guo, Yan
    Yang, Zhongwei
    Hou, Guojin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S28 - S35
  • [25] Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
    Huang, Shaolong
    Zhang, Yazhong
    Zhang, Xu
    Zhou, Chengqiang
    Li, Wenbo
    Wang, Yunqing
    Wang, Bin
    Zhu, Ziqiang
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [26] Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
    Shaolong Huang
    Yazhong Zhang
    Xu Zhang
    Chengqiang Zhou
    Wenbo Li
    Yunqing Wang
    Bin Wang
    Ziqiang Zhu
    BioMedical Engineering OnLine, 22
  • [27] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiang, Jiabao
    Chen, Jialei
    Xing, Fei
    Liu, Hao
    Xiang, Zhou
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [28] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiabao Jiang
    Jialei Chen
    Fei Xing
    Hao Liu
    Zhou Xiang
    BMC Musculoskeletal Disorders, 24
  • [29] Femoral Neck System vs. four cannulated screws in the treatment of Pauwels III femoral neck fracture
    Lin, Hongkuan
    Lai, Caosheng
    Zhou, Zhiping
    Wang, Chaoqiang
    Yu, Xinlin
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2023, 28 (06) : 1373 - 1378
  • [30] Fixation of femoral neck fractures using divergent versus parallel cannulated screws
    Papanastassiou I.D.
    Mavrogenis A.F.
    Kokkalis Z.T.
    Nikolopoulos K.
    Skourtas K.
    Papagelopoulos P.J.
    Journal of Long-Term Effects of Medical Implants, 2011, 21 (01) : 63 - 69