Effects of prospective motion correction on perivascular spaces at 7T MRI evaluated using motion artifact simulation

被引:1
|
作者
Zhao, Bingbing [1 ]
Zhou, Yichen [1 ]
Zong, Xiaopeng [1 ]
机构
[1] ShanghaiTech Univ, Sch Biomed Engn, 393 Middle Huaxia Rd, Shanghai, Peoples R China
基金
美国国家卫生研究院;
关键词
high-field MRI; motion artifact simulation; perivascular spaces; prospective motion correction; WHITE-MATTER; MARKER; SYSTEM;
D O I
10.1002/mrm.30126
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe effectiveness of prospective motion correction (PMC) is often evaluated by comparing artifacts in images acquired with and without PMC (NoPMC). However, such an approach is not applicable in clinical setting due to unavailability of NoPMC images. We aim to develop a simulation approach for demonstrating the ability of fat-navigator-based PMC in improving perivascular space (PVS) visibility in T2-weighted MRI.MethodsMRI datasets from two earlier studies were used for motion artifact simulation and evaluating PMC, including T2-weighted NoPMC and PMC images. To simulate motion artifacts, k-space data at motion-perturbed positions were calculated from artifact-free images using nonuniform Fourier transform and misplaced onto the Cartesian grid before inverse Fourier transform. The simulation's ability to reproduce motion-induced blurring, ringing, and ghosting artifacts was evaluated using sharpness at lateral ventricle/white matter boundary, ringing artifact magnitude in the Fourier spectrum, and background noise, respectively. PVS volume fraction in white matter was employed to reflect its visibility.ResultsIn simulation, sharpness, PVS volume fraction, and background noise exhibited significant negative correlations with motion score. Significant correlations were found in sharpness, ringing artifact magnitude, and PVS volume fraction between simulated and real NoPMC images (p <= 0.006). In contrast, such correlations were reduced and nonsignificant between simulated and real PMC images (p >= 0.48), suggesting reduction of motion effects with PMC.ConclusionsThe proposed simulation approach is an effective tool to study the effects of motion and PMC on PVS visibility. PMC may reduce the systematic bias of PVS volume fraction caused by motion artifacts.
引用
收藏
页码:1079 / 1094
页数:16
相关论文
共 50 条
  • [21] Motion Artifact Reduction in Pediatric Diffusion Tensor Imaging Using Fast Prospective Correction
    Alhamud, A.
    Taylor, Paul A.
    Laughton, Barbara
    van der Kouwe, Andre J. W.
    Meintjes, Ernesta M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (05) : 1353 - 1364
  • [22] Study protocol: value of 7-T MRI with prospective motion correction and postprocessing for patients with nonlesional epilepsy
    Kukhlenko, O.
    Kukhlenko, R.
    Tempelmann, C.
    Speck, O.
    Hinrichs, H.
    Heinze, H. -j.
    Heers, M.
    House, P. M.
    Woermann, F. G.
    Knake, S.
    Urbach, H.
    Huppertz, H. -j.
    Haghikia, A.
    Schmitt, F. C.
    CLINICAL EPILEPTOLOGY, 2023, 36 (04) : 320 - 326
  • [23] Impaired damping of cerebral blood flow velocity pulsatility is associated with the number of perivascular spaces as measured with 7T MRI
    van den Kerkhof, Marieke
    van der Thiel, Merel M.
    van Oostenbrugge, Robert J.
    Postma, Alida A.
    Kroon, Abraham A.
    Backes, Walter H.
    Jansen, Jacobus F. A.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2023, 43 (06): : 937 - 946
  • [24] Real-time motion and retrospective coil sensitivity correction for CEST using volumetric navigators (vNavs) at 7T
    Poblador Rodriguez, Esau
    Moser, Philipp
    Auno, Sami
    Eckstein, Korbinian
    Dymerska, Barbara
    van der Kouwe, Andre
    Gruber, Stephan
    Trattnig, Siegfried
    Bogner, Wolfgang
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) : 1909 - 1923
  • [25] Highest Resolution In Vivo Human Brain MRI Using Prospective Motion Correction
    Stucht, Daniel
    Danishad, K. Appu
    Schulze, Peter
    Godenschweger, Frank
    Zaitsev, Maxim
    Speck, Oliver
    PLOS ONE, 2015, 10 (07):
  • [26] Knee Cartilage MRI with In Situ Mechanical Loading Using Prospective Motion Correction
    Lange, Thomas
    Maclaren, Julian
    Herbst, Michael
    Lovell-Smith, Cris
    Izadpanah, Kaywan
    Zaitsev, Maxim
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 516 - 523
  • [27] Segmentation of Perivascular Spaces Using Vascular Features and Structured Random Forest from 7T MR Image
    Zhang, Jun
    Gao, Yaozong
    Park, Sang Hyun
    Zong, Xiaopeng
    Lin, Weili
    Shen, Dinggang
    MACHINE LEARNING IN MEDICAL IMAGING, MLMI 2016, 2016, 10019 : 61 - 68
  • [28] Unsupervised motion artifact correction of turbo spin-echo MRI using deep image prior
    Lee, Jongyeon
    Seo, Hyunseok
    Lee, Wonil
    Park, Hyunwook
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (01) : 28 - 42
  • [29] Robust high spatio-temporal line-scanning fMRI in humans at 7T using multi-echo readouts, denoising and prospective motion correction
    Raimondo, Luisa
    Priovoulos, Nikos
    Passarinho, Catarina
    Heij, Jurjen
    Knapen, Tomas
    Dumoulin, Serge O.
    Siero, Jeroen C. W.
    van der Zwaag, Wietske
    JOURNAL OF NEUROSCIENCE METHODS, 2023, 384
  • [30] Control of a wireless sensor using the pulse sequence for prospective motion correction in brain MRI
    van Niekerk, Adam
    Berglund, Johan
    Sprenger, Tim
    Norbeck, Ola
    Avventi, Enrico
    Ryden, Henric
    Skare, Stefan
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (02) : 1046 - 1061