Clinical application of single-shot fast spin-echo sequence for cerebrospinal fluid flow MR imaging

被引:1
|
作者
Bessho, Takahito [1 ,4 ]
Hayashi, Tatsuya [2 ]
Shibukawa, Shuhei [3 ]
Kourin, Kazuyuki [1 ]
Shouda, Takashi [1 ]
机构
[1] Houju Mem Hosp, Diagnost Imaging Room,11-71 Midorigaoka, Nomi, Ishikawa 9231226, Japan
[2] Teikyo Univ, Grad Sch Med Technol, 2-11-1 Kaga,Itabashi Ku, Tokyo, Tokyo 1738605, Japan
[3] Juntendo Univ, Fac Hlth Sci, Dept Radiol Technol, 2-1-1 Hongo,Bunkyo-Ku, Tokyo 1138421, Japan
[4] Kanazawa Med Univ Hosp, Cent Radiat Dept, 1-1 Uchinada, Kahoku, Ishikawa 9200293, Japan
关键词
Cerebrospinal fluid; Normal-pressure hydrocephalus; Single-shot fast spin echo; Phase contrast; Saturation pulse; VISUALIZATION; MOTION;
D O I
10.1007/s12194-024-00825-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In normal-pressure hydrocephalus, disturbances in cerebrospinal fluid (CSF) circulation occur; therefore, understanding CSF dynamics is crucial. The two-dimensional phase-contrast (2D-PC) method, a common approach for visualizing CSF flow on MRI, often presents challenges owing to prominent vein signals and excessively high contrast, hindering the interpretation of morphological information. Therefore, we devised a new imaging method that utilizes T2-weighted high-signal intensification of the CSF and saturation pulses, without requiring specialized imaging sequences. This sequence utilized a T2-weighted single-shot fast spin-echo combined with multi-phase imaging synchronized with a pulse wave. Optimal imaging conditions (repetition time, presence/absence of fast recovery, and echo time) were determined using self-made contrast and single-plate phantoms to evaluate signal-to-noise ratio, contrast ratio, and spatial resolution. In certain clinical cases of hydrocephalus, confirming CSF flow using 2D-PC was challenging. However, our method enabled the visualization of CSF flow, proving to be useful in understanding the pathophysiology of hydrocephalus.
引用
收藏
页码:782 / 792
页数:11
相关论文
共 50 条
  • [31] Fat-suppressed T2-weighted MR imaging of the liver: Comparison of respiratory triggered fast spin-echo, breath-hold single-shot fast spin-echo and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Sakahara, H
    Nozaki, A
    RADIOLOGY, 2000, 217 : 587 - 587
  • [32] Single-shot turbo spin-echo MR myelography: comparison with 3D-turbo spin-echo MR myelography and T2-turbo spin-echo at 1 T
    Karantanas, AH
    Zibis, AH
    Papanikolaou, N
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2000, 24 (01) : 37 - 42
  • [33] Three-dimensional fast-recovery fast spin-echo MRCP: Comparison with two-dimensional single-shot fast spin-echo techniques
    Sodickson, A
    Mortele, KJ
    Barish, MA
    Zou, KH
    Thibodeau, S
    Tempany, CMC
    RADIOLOGY, 2006, 238 (02) : 549 - 559
  • [34] Cardiac MR elastography using reduced-FOV, single-shot, spin-echo EPI
    Sui, Yi
    Arunachalam, Shivaram P.
    Arani, Arvin
    Trzasko, Joshua D.
    Young, Phillip M.
    Glockner, James F.
    Glaser, Kevin J.
    Lake, David S.
    McGee, Kiaran P.
    Manduca, Armando
    Rossman, Phillip J.
    Ehman, Richard L.
    Araoz, Philip A.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 231 - 238
  • [35] The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma
    Bert De Foer
    Jean-Philippe Vercruysse
    Anja Bernaerts
    Joachim Maes
    Filip Deckers
    Johan Michiels
    Thomas Somers
    Marc Pouillon
    Erwin Offeciers
    Jan W. Casselman
    Neuroradiology, 2007, 49 : 841 - 848
  • [36] Diffusion-weighted imaging of the appendicular skeleton with a non-Carr-Purcell-Meiboom-Gill single-shot fast spin-echo sequence
    Oener, Ali Yusuf
    Aggunlu, Levent
    Akpek, Sergin
    Tali, Turgut
    Celik, Azim
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) : 1494 - 1501
  • [37] The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma
    De Foer, Bert
    Vercruysse, Jean-Philippe
    Bernaerts, Anja
    Maes, Joachim
    Deckers, Filip
    Michiels, Johan
    Somers, Thomas
    Pouillon, Marc
    Offeciers, Erwin
    Casselman, Jan W.
    NEURORADIOLOGY, 2007, 49 (10) : 841 - 848
  • [38] Crohn disease with endoscopic correlation: Single-shot fast spin-echo and gadolinium-enhanced fat-suppressed spoiled gradient-echo MR imaging
    Low, RN
    Sebrechts, CP
    Politoske, DA
    Bennett, MT
    Flores, S
    Snyder, RJ
    Pressman, JH
    RADIOLOGY, 2002, 222 (03) : 652 - 660
  • [39] Fast spin-echo MR imaging of the pediatric brain
    Engelbrecht, V
    Malms, J
    Kahn, T
    Grunewald, S
    Modder, U
    PEDIATRIC RADIOLOGY, 1996, 26 (04) : 259 - 264
  • [40] Liver T2-weighted MR imaging: Comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences
    Tang, Y
    Yamashita, Y
    Namimoto, T
    Abe, Y
    Takahashi, M
    RADIOLOGY, 1997, 203 (03) : 766 - 772