Optimal design of hybrid renewable energy sources with battery storage using an efficient weighted mean of vectors algorithm

被引:3
|
作者
Abd El-Sattar, Hoda [1 ]
Houssein, Essam H. [2 ]
Hashim, Fatma A. [3 ]
Kamel, Salah [4 ]
机构
[1] Luxor Higher Inst Engn & Technol, Luxor 85834, Egypt
[2] Minia Univ, Fac Comp & Informat, Al Minya, Egypt
[3] Helwan Univ, Fac Engn, Cairo, Egypt
[4] Aswan Univ, Fac Engn, Dept Elect Engn, Aswan 81542, Egypt
关键词
Modified weighted mean of vectors algorithm (mINFO); CEC'20 test suite; Hybrid renewable energy; Biomass system; Energy cost; Battery storage; OPTIMIZATION ALGORITHM; SYSTEM; MANAGEMENT; SOLAR; COST;
D O I
10.1016/j.est.2024.111387
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An improved algorithm called mINFO is developed, based on the modification of the original weIghted meaN oF vectOrs Optimizer (INFO). In this article, to enhance the original INFO method, an improved version called mINFO is presented by incorporating the sine-cosine function and balancing exploration/exploitation strategy through the control randomization parameter. This suggested mINFO algorithm is applied to obtain the optimal size design of two hybrid renewable power sources (HRPS), the first configuration consists of the photovoltaic (PV)/biomass system (BS)/fuel cells (FC) and the second configuration consists of the PV/BS/battery storage units. This HRPS are designed to generate the power needed to meet the loads supply on the campus of Aswan University in the Sahary region of Aswan city, Egypt. The proposed mINFO approach is developed to avoid the weaknesses of the original INFO method by enhancing the balance between the exploration and exploitation phases and preventing the conventional INFO method from getting stuck in local minima. In order to prove the efficiency and robust search capabilities of the developed mINFO algorithm, the mINFO algorithm is tested by using 10 IEEE CEC ' 20 test suites and its results are compared with the original INFO method and other wellknown optimization algorithms. The proposed mINFO algorithm achieved the first rank in terms of the Friedman mean rank-sum test over F2, F3, F4, F6, F9, and F10, and the second rank after the original INFO algorithm over F1 and F7. Boxplot analysis is also used to show the features of data distribution. For the majority of functions, the boxplots generated by the mINFO algorithm have the narrowest ranges of values out of all comparison algorithms. As a result, for the majority of test functions, the mINFO algorithm shows more promise than its competitors. The main objectives of the suggested HRPS are to minimize energy cost (EC), excess energy (EXE), and maximize the power system's reliability (LPSP). By applying the mINFO algorithm to find the optimal sizing for the two configurations proposed in this study and by comparing the mINFO results with other algorithms such as the original INFO, Particle Swarm optimization (PSO), Runge Kutta optimization (RUN), Sooty Tern Optimization Algorithm (STOA), and Gray Wolf optimization (GWO). The proposed mINFO method shows the best results for the two suggested configurations compared to the other algorithms used by studying the systems for 100 iterations and 50 times run. For the PV/BS/battery units, the best optimal solution has achieved after 36 iterations with the lowest EC with 0.11676275 $/kWh, net present cost (NPC) with 3,420,036 $, EXE with 0.090282 and LPSP with 0.0419687649, while for the PV/BS/FC units, the optimal solution has achieved after 11 iterations with the minimal EC with 0.17996701 $/kWh, NPC with 5,271,318 $, EXE with 0.150022 and LPSP with 0.07598679.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Hybrid Renewable Energy Systems: Impact of thermal storage on systems optimal design and performance
    Bartolucci, Lorenzo
    Cordiner, Stefano
    Mulone, Vincenzo
    Pasquale, Stefano
    Santarelli, Marina
    74TH ATI NATIONAL CONGRESS: ENERGY CONVERSION: RESEARCH, INNOVATION AND DEVELOPMENT FOR INDUSTRY AND TERRITORIES, 2019, 2191
  • [42] Renewable Integration Algorithm to Compensate PV Power Using Battery Energy Storage System
    Lee, Hyung-Joo
    Choi, Jin-Young
    Park, Gun-Soo
    Oh, Kyo-Sun
    Won, Dong-Jun
    2017 6TH INTERNATIONAL YOUTH CONFERENCE ON ENERGY (IYCE), 2017,
  • [43] Efficient Energy Management in a Microgrid with Intermittent Renewable Energy and Storage Sources
    Ramli, Makbul A. M.
    Bouchekara, H. R. E. H.
    Alghamdi, Abdulsalam S.
    SUSTAINABILITY, 2019, 11 (14)
  • [44] Optimal Energy Management of a Hybrid Electric Bus with a Battery-Supercapacitor Storage System using Genetic Algorithm
    Herrera, Victor Isaac
    Saez-de-Ibarra, Andoni
    Milo, Aitor
    Gaztanaga, Haizea
    Camblong, Haritza
    2015 INTERNATIONAL CONFERENCE ON ELECTRICAL SYSTEMS FOR AIRCRAFT, RAILWAY, SHIP PROPULSION AND ROAD VEHICLES (ESARS), 2015,
  • [45] Design and optimal sizing of hybrid PV/wind/diesel system with battery storage by using DIRECT search algorithm
    Zhang, Lu
    Barakat, Georges
    Yassine, Adnan
    2012 15TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE/PEMC), 2012,
  • [46] Optimal design of hybrid renewable energy systems (HRES) using hydrogen storage technology for data center applications
    Iverson, Zachariah
    Achuthan, Ajit
    Marzocca, Pier
    Aidun, Daryush
    RENEWABLE ENERGY, 2013, 52 : 79 - 87
  • [47] Efficient design of hybrid renewable energy systems using evolutionary algorithms
    Bernal-Agustin, Jose L.
    Dufo-Lopez, Rodolfo
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (03) : 479 - 489
  • [48] Toward Forecast Techniques in Optimal Sizing of Energy Storage System with Volatile Energy Sources for Hybrid Renewable Energy System
    Kwangkaew, Akanit
    Racharak, Teeradaj
    Charoenlarpnopparut, Chalie
    2020 INTERNATIONAL CONFERENCE ON SMART GRIDS AND ENERGY SYSTEMS (SGES 2020), 2020, : 390 - 395
  • [49] Optimal Battery Energy Storage System Control in Microgrid with Renewable Energy Generation
    Tang, Wanrong
    Zhang, Ying Jun
    2015 IEEE INTERNATIONAL CONFERENCE ON SMART GRID COMMUNICATIONS (SMARTGRIDCOMM), 2015, : 846 - 851
  • [50] Demand Side Management for Stand-Alone Microgrid Using Coordinated Control of Battery Energy Storage System and Hybrid Renewable Energy Sources
    Jha, Sumit Kumar
    Kumar, Deepak
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2019, 47 (14-15) : 1261 - 1273