Shaking Table Test on 1/2-Scale Model of Column-and-Tie Timber Structure Filled with Wooden Walls

被引:5
|
作者
Xue J. [1 ]
Guo R. [1 ]
Xu D. [1 ]
Qi L. [1 ]
He Z. [1 ]
机构
[1] Dept. of Civil Engineering, Xi'an Univ. of Architecture and Technology, Xi'an, Shaanxi
来源
Journal of Structural Engineering (United States) | 2020年 / 146卷 / 12期
基金
中国国家自然科学基金;
关键词
Column-and-tie timber structure; Dynamic characteristic; Energy dissipation behavior; Seismic response; Shaking table test; Wooden wall;
D O I
10.1061/(ASCE)ST.1943-541X.0002832
中图分类号
学科分类号
摘要
To study the influence of wooden walls on the seismic performance of traditional Chinese column-and-tie timber structures, two 1/2-scale two-story and two-span timber structure models were fabricated. The infill wall was not installed in model 1, while model 2 deployed wooden walls for comparison. The damage characteristics, seismic responses, and energy dissipation behaviors of the two models under the seismic ground motions of varying intensity were obtained through shaking table tests. The comparative analyses of the seismic performance of the two models indicated that the pull-out length of the tenon and the slippage degree of the column foot of model 1 were greater than those of model 2 with the same input. Moreover, the first natural frequency of model 2 was greater than that of model 1 due to the existence of the wooden walls, and the stiffness degradation rate of model 2 was lower than that of model 1. The first damping ratio of model 1 was between 10.2% and 15.0%, and that of model 2 was between 9.3% and 21.9%. The acceleration amplification factors of the two models were basically less than 1, which was significantly different from regular reinforced concrete structures or steel structures. When the input peak ground acceleration reached 0.22g (the maximum considered earthquake for the region with intensity seven), the maximum story drifts of the two models were 1/47 and 1/59, respectively, which met the story drift limit of 1/30 for timber frames in the Chinese Seismic Code for Timber Structures. The lateral stiffness of model 2 increased because of the existence of the wooden walls when compared with model 1. The energy dissipation of model 2 was greater than that of model 1 under the same earthquake excitation in terms of the deformation of the wooden walls and squeezing interaction between the timber frame and wooden walls. © 2020 American Society of Civil Engineers.
引用
收藏
相关论文
共 25 条
  • [21] Shaking table test and numerical analysis of a 1:12 scale model of a special concentrically braced steel frame with pinned connections
    Yu Haifeng
    Zhang Wenyuan
    Zhang Yaochun
    Sun Yusong
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2010, 9 (01) : 51 - 63
  • [22] Shaking table test and numerical analysis of a 1:12 scale model of a special concentrically braced steel frame with pinned connections
    Haifeng Yu
    Wenyuan Zhang
    Yaochun Zhang
    Yusong Sun
    Earthquake Engineering and Engineering Vibration, 2010, 9 : 51 - 63
  • [23] Shaking table test on overall-scale model of long-span steel structure of Beijing Daxing International Airport terminal
    Zhang A.
    Wang X.
    Liu X.
    Shu W.
    Zhu Z.
    Qiang S.
    Jiang Z.
    Feng S.
    Liu, Xuechun (liuxuechun@bjut.edu.cn), 1600, Science Press (42): : 1 - 13
  • [24] Dynamic response analysis of liquefied site-pile group foundation-structure system -large-scale shaking table model test
    Xu C.-S.
    Dou P.-F.
    Du X.-L.
    Chen S.
    Li X.
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2019, 41 (12): : 2173 - 2181
  • [25] Super-detailed FEM simulations for full-scale steel structure with fatal rupture at joints between members-Shaking-table test of full-scale steel frame structure to estimate influence of cumulative damage by multiple strong motion: Part 1
    Mizushima, Yasunori
    Mukai, Yoichi
    Namba, Hisashi
    Taga, Kenzo
    Saruwatari, Tomoharu
    JAPAN ARCHITECTURAL REVIEW, 2018, 1 (01): : 96 - 108