A Review of the Effectiveness of Shielding Curtains for Improving Radiation Safety Management of Electromagnetic Radiation in Diagnostic X-ray Rooms

被引:0
|
作者
Kim, Jeong-Ho [1 ]
Kim, Gap-Jung [2 ]
Yoo, Se-Jong [3 ]
Ju, Myeong-Sik [2 ]
机构
[1] Sunlin Univ, Dept Radiol Sci, Pohang 37560, South Korea
[2] Songho Univ, Dept Radiol Sci, Hoengseong 25242, South Korea
[3] Konyang Univ, Dept Radiol Sci, Daejeon 35365, South Korea
关键词
electro-magnetic radiation shielding; electro-magnetic radiation; curtain; lead;
D O I
10.4283/JMAG.2023.28.4.438
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
During diagnostic radiography examinations, due to problems such as patient falls, the door between the examination room and the control room is often opened for quick action. Therefore, the purpose of this study is to evaluate the effectiveness of curtain-type shielding for worker radiation protection. Shielding efficiency, weight, cost, and user opinions were analyzed for leaded, leaded rubber, lead-free shielding sheet, and chainmail. The results showed that the shielding efficiency was 97.7 % for the steel door, 97.5 % for the lead sheet, 97.0 % for the lead rubber, 96.0 % for the lead-free sheet, and 91.3 % for the chain mail, and the weight was 7,399 g for the lead sheet, 8,482 g for the lead rubber, 1,148 g for the lead-free sheet, and 8,127 g for the chain mail. The cost was $46.9 for the lead sheet, $126 for the lead rubber, $270.5 for the lead-free sheet, and $147.8 for the chain mail. Based on this, it is believed that shielding curtains can be used to provide both worker and patient safety by considering the conditions of diagnostic radiography rooms in each medical institution.
引用
收藏
页码:438 / 442
页数:5
相关论文
共 50 条
  • [1] Modern requirements for radiation safety of x-ray diagnostic rooms
    Blinov N.N.
    Kozlovskii E.B.
    Biomedical Engineering, 2008, 42 (5) : 247 - 248
  • [2] A HISTORY OF RADIATION SHIELDING OF X-RAY THERAPY ROOMS
    MCGINLEY, PH
    MINER, MS
    HEALTH PHYSICS, 1995, 69 (05): : 759 - 765
  • [3] SIMPLIFIED SHIELDING FOR DIAGNOSTIC X-RAY ROOMS
    RUMMERFIELD, PS
    HEALTH PHYSICS, 1978, 35 (05): : 718 - 720
  • [4] An evaluation of the effectiveness of current shielding methodologies for diagnostic X-ray and radiation therapy facilities
    Shearer, D
    Donovan, G
    North, D
    Cardarelli, G
    MEDICAL PHYSICS, 2003, 30 (06) : 1399 - 1399
  • [5] Radiation attenuation and elemental composition of locally available ceramic tiles as potential radiation shielding materials for diagnostic X-ray rooms
    Zakaria, Mohd Aizuddin
    Razab, Mohammad Khairul Azhar Abdul
    Adenan, Mohd Zulfadli
    Ahmad, Muhammad Zabidi
    Tajudin, Suffian Mohamad
    Samson, Damilola Oluwafemi
    Aziz, Mohd Zahri Abdul
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (01) : 301 - 308
  • [6] Radiation Protection of X-Ray Rooms
    E. G. Chikirdin
    Biomedical Engineering, 2001, 35 (2) : 60 - 64
  • [7] EFFECTIVENESS OF MASS SURVEY OF DIAGNOSTIC X-RAY EQUIPMENT IN PROMOTING RADIATION SAFETY
    SHARP, CM
    WILLIAMS, EG
    KNAPP, JR
    RADIOLOGY, 1961, 76 (01) : 121 - 121
  • [8] Measurement of stray x-ray radiation as a part of radiation control of x-ray rooms
    Berlyand V.A.
    Volegov P.L.
    Platonov N.N.
    Biomedical Engineering, 1998, 32 (3) : 137 - 139
  • [9] RADIATION SHIELDING OF MULTIPLE X-RAY SOURCES IN DIAGNOSTIC-RADIOLOGY
    SIMPKIN, DJ
    HEALTH PHYSICS, 1986, 50 (01): : 117 - 122
  • [10] The Radiation Shielding Design of X-Ray Velocimeter
    Bo, Yang
    2016 3RD INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2016, : 650 - 654